High Temperature Casing Condition (HTCC) Tool SUITE Richard Williams
HTCC-MF + HTCC-EM MF module can be run in conjunction with the EM module EM module MF module
HTCC-MF HTCC-MF Multi Finger tool Smart 60 fingers High temperature Real-time or Memory Quantitative
HTCC-MF 60 fingers 7 to 13-5/8 inch casing – full range Designed to work at 300°C and 350bar High temperature electronics (sensors, motor) Flasked design – Electronics finite time down hole
Fingers 60 fingers - Good coverage around the circumference 20 measurements per second
Inclination and Roll Inclination and Roll measured concurrently with finger measurements Roll allows the high side of the well Inclination measures the deviation of the well.
HTCC Reporting
3D – fly through casing
Cross section
Example – Deformed (ovalized) casing
Example – Scale buildup
Example – Pulled coupling
Example - External corrosion
Conclusion High temperature operation Quantitative analysis of inside of the casing Qualitative analysis of the outside of the casing 3D view of the well