2014_ES_Valvdvssvsdvole per radiatori.pptx

pbernal6 8 views 46 slides Sep 15, 2025
Slide 1
Slide 1 of 46
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46

About This Presentation

cx bv vvbcv


Slide Content

VÁLVULAS Y ACCESORIOS PARA ELEMENTOS CALEFACTORES

VÁLVULAS PARA RADIADORES

VÁLVULAS CONVENCIONALES VÁLVULAS PARA RADIADORES

VÁLVULAS PARA RADIADORES

VÁLVULAS PARA RADIADORES

VÁLVULA DETENTOR El acoplamiento de la perilla en la barra de control se hace con una simple presión manual, sin tornillo. Desmontaje para cualquier operaciones de mantenimiento o el reemplazo son igual de fácil. VÁLVULAS CONVENCIONALES Regulación manual

VÁLVULAS CONVENCIONALES Regulación manual

VÁLVULAS PARA RADIADORES

La varilla de mando (1) es de acero inoxidable, con doble anillo de O-Ring de EPDM. De esta manera la parte superior del tornillo sinfin (2) se puede cambiar inclusive con la instalación en funciónamiento . El obturador (3) ha sido diseñado para optimizar las caractéristicas fluidodinámicas de la válvula durante la acción progresiva de apertura o cierre en el funcionamiento termostático. El amplio espacio entre el asiento y el obturador determina escasas pérdidas de carga en el modo de funcionamiento manual. VÁLVULAS CONVENCIONALES Válvulas termostatizables

VÁLVULAS CONVENCIONALES Válvulas termostatizables Válvula cerrada Válvula abierta

VÁLVULAS CONVENCIONALES Válvulas termostatizables

VÁLVULAS PARA RADIADORES

1) Quitar el mando (1) de la válvula. 2) Levantar el disco (2) del dispositivo de pre-regulación y girar el eje para seleccionar la posición deseada. 3) Bajar otra vez el disco 4) Colocar en la válvula el mando manual , el mando termostático o el mando electrotérmico . VÁLVULAS CONVENCIONALES Válvulas termostatizables con pre-regulación

The convertible radiator valves are equipped with an internal device (1) for pre-setting the head loss hydraulic characteristics. Specific passage cross sections (3) can be selected by means of the control nut (2), in order to generate the required resistance to the motion of the medium. TRADITIONAL VALVE Convertible valve with pre-setting Each passage cross section determines a specific Kv value for the creation of the head loss, which corresponds to a setting position on a graduated scale (4). Depending on the position in the system, the valve can be pre-setted so as to obtain an immediate balancing of the hydraulic circuit, valid for both manual and thermostatic operation. (3) Flat development of the internal pre-setting device

VÁLVULAS CONVENCIONALES Válvula termostatizable c on pre-regulación

VÁLVULAS PARA RADIADORES

VÁLVULAS CONVENCIONALES Válvulas termostáticas

VÁLVULAS CONVENCIONALES Detentores

VÁLVULAS CONVENCIONALES Válvulas termostáticas

VÁLVULAS MONOTUBO O BITUBO VÁLVULAS PARA RADIADORES

SISTEMAS MONOTUBO Y BITUBO

SISTEMAS MONOTUBO Y BITUBO

SISTEMAS MONOTUBO Y BITUBO

SISTEMAS MONOTUBO Y BITUBO

VÁLVULAS PARA RADIADORES VÁLVULAS PARA RADIADORES TOALLEROS

ANGLED CONNECTIONS DOUBLE ANGLE CONNECT. CENTRAL CONNECT. RIGHT-HAND VERSION LEFT-HAND VERSION DESIGNER HEATING SYSTEMS High-style valves 4001 4003 4003 4004 4004

SISTEMAS CON RADIADORES TOALLEROS Válvulas high-style

SISTEMAS CON RADIADORES TOALLEROS Válvulas high-style

SISTEMAS CON RADIADORES TOALLEROS Válvulas high-style

VÁLVULAS PARA RADIADORES VÁLVULAS PARA PANELES CONVECTORES

Se instalan en un especial tipo de paneles con las conexiones abajo y un tramo interior, no visible desde el exterior, que lleva el flujo de envío a la válvula superior . SISTEMAS CON PANELES CONVECTORES

A SQUADRA DIRITTA MONOVALVOLA PER IMPIANTI BITUBO 3010 3011 MONOVALVOLA PER IMPIANTI MONOTUBO CON DISPOSITIVO ANTICIRCOLAZIONE E BY-PASS REGOLABILE 3012 3013 VALVOLA SINGOLA 3014 3015 SISTEMAS CON PANELES CONVECTORES

MANDO TERMOSTÁTICO MANDO ELÉCTRICO MANDO TERMOSTÁTICO Tipos

MANDO TERMOSTÁTICO Tipos

Los mandos termostáticos deben instalarse en posición horizontal . El elemento sensible del cabezal termostático no debe instalarse en nichos, cajones, cortinas, ni a la exposición directa del sol para no falsear los valores. MANDO TERMOSTÁTICO Instalación

MANDO TERMOSTÁTICO Instalación

MANDO ELECTROTÉRMICO

VÁLVULA DE BY-PASS DIFERENCIAL

VÁLVULA DE BY-PASS DIFERENCIAL

VÁLVULA DE BY-PASS DIFERENCIAL POSIBLE RUIDO SOBRECALENTAMIENTO DE LA BOMBA La válvula de by-pass se utiliza en instalaciones donde puede haber notables variaciones de caudal, por ejemplo las que tienen un gran número de válvulas termostáticas o válvulas motorizadas de dos vías. Asegura una recirculación del líquido proporcional al número de válvulas que se cierran, limitando el valor máximo de la presión diferencial generada por la bomba.

VÁLVULA DE BY-PASS DIFERENCIAL Variaciones de presión

VÁLVULA DE BY-PASS DIFERENCIAL Variaciones de presión

VÁLVULA DE BY-PASS DIFERENCIAL Variaciones de presión

VÁLVULA DE BY-PASS DIFERENCIAL Variaciones de presión

VÁLVULA DE BY-PASS DIFERENCIAL I nstalación CALDERA NORMAL CALDERA DE CONDENSACIÓN La caldera de condensación requiere temperaturas de retorno bajas. T M > T R T M = T R columna fría columna caliente
Tags