Features – Configuration( Fixed frequency type ) Copeland brand compressor Water side shell & tube heat exchanger Built-in distributor Without frost cracking --10 times freeze-damage tests Without rupture -- 250000 times ~ 4.2MPa pressure alternating test All-metal low-noise axial fan Standard RS485 interface E asy access to BAS W ired controller 7-inch color touch controller (optional) Fast adjustment Wide range adjustment High precision adjustment Electronic expansion valve *Increase heat exchange area *Uniform air distribution V-shaped structure TCA: Combine up to 16 units
Features – Configuration( Inverter type ) Mitsubishi DC inverter scroll compressor Outlet- High press. Suction inlet- Low press. Injection port- Medium press. Suction inlet- Medium press. Refrigerant cooling- Compressor driven All-aluminum integrated plate Patent No : CN201621167898 Patent No : 202020931775.1 Compressor mute design Quintuple sound insulation Double U structure *The windward area increased by 45 % *Smooth return air on all sides Full DC brushless fan motor *15~100% stepless speed regulation *More stable operation *Lower noise Standard RS485 interface E asy access to BAS 7-inch color touch controller (optional) TCAV: Combine up to 16 units W ired controller
7-inch color touch controller Intelligent defrosting Fast adjustment Wide range adjustment High precision adjustment Electronic expansion valve Standard RS485 interface E asy access to BAS *Increase heat exchange area *Uniform air distribution V-shaped structure Danfoss brand : TAS165/260 Copeland brand : TAS340/460 Water side shell & tube heat exchanger Built-in distributor Without frost cracking --10 times freeze-damage tests Without rupture -- 250000 times ~ 4.2MPa pressure alternating test TAS : Combine up to 8 units Features – Configuration( Large capacity type )
Energy regulation control procedure: PID control *Water temp. control more accurate *Loading faster Loading: Each module has priority to load one system, and all modules can load the second system after loading one system of each module. Unloading: Each module shall unload one system first, and all modules shall unload the second system after unloading one system of each module. VS Air volume grading control ( Patent No : ZL 201620902076.8 ) Fan loading and unloading : According to ambient temp. Optimal matching of air volume and load; No frequent start and stop; System stability; Stable water temp.; Intelligent energy regulation technology ( Patent No : ZL201320344732.3) Control the number of fans Control two-speed fan & its number Advantage- Control patent
Advantage- Control patent R esponded quickly Dynamic matching Accurate control Throttle control technology ( Patent No : ZL 2013 2 0345187.X ) System pressure Schematic diagram of adjustment curve Stability time/min Intelligent defrosting technology Bottom check valve design ( Patent No : 201620902099.9 ) ( Patent No : 201620695725.1 ) T Interval Bottom suspended design Heating capacity output Time/s Intelligent defrosting Common defrosting Defrost entry conditions: Comprehensive judgment based on the ambient temp., evaporation temp., operation time and other parameters of heating operation. Frost prevention in advance Smooth drainage
Advantage - B lack box Convenient program upgrade Ultra-large storage space Easy after-sales fault analysis USB Data kept for ten years
Temperature Sensor 1m The Temperature Sensor installed on the main pipe (water outlet pipe) , and only one control system is needed for one system Free combination of up to 16 units of inverter and fixed speed modules *The inverter chiller :master unit ; the fixed speed : slave unit. *The inverter has the loading priority upon partial loading requirement while the fixed speed has the priority to be un loaded. Advantage - Intelligent combination
TCA201XH TCA401XH TCA201XC, TCA401XC Inverter chiller as master unit TCAV65BHE TCAV130BHE Recommend combination ( Between different series ) : TCA201XH, TCA301XH, TCA401XH TCA201XHE, TCA401XHE TCA201XC , TCA401XC TCA201XHA TCAV035BHE Heat pump chiller as master unit Master unit Slave unit Advantage - Intelligent combination The same series of units can combine.
Optional Item Wiring controller wire length Note Standard Optional Controller No Wired controller : ; Touch screen controller : TCA(V): Combine up to 16 units TAS: Combine up to 8 units Auxiliary electric heating No 12/15/18/20/27/32/40/45/50/54/63/72kW Wired controller wire length 30m 60/120m Air Side Heat Exchanger anticorrosion No Yes A ll year round cooling(TAS) TAS260AH ≥ -10 ℃ TAS340BH ≥ -15 ℃ TAS460BH ≥ -15 ℃ Low C hilled Water Outlet T emp. No 0~5 ℃: TCA-XH/XC/XHA(Only touch screen) 0/-5/-10 ℃: TCAV-BHE
Reference Projects 3
Reference Projects( Pharmacy ) Project : Alexander Hospital Country : Russia Project : Citi Doctor Country : Ukraine Project : ZAMIN BIO HEALTH Country : Uzbekistan Project : Clever Medical Country : Kazakhstan Project : Biocad Country : Russia Project : "OTCPharm" Country : Russia
Reference Projects( Commercial industry ) Project : Sberbank Country : Russia Project : Opera and Ballet Theatre Country : Russia Project : ASTONIA Tbilisi Country : Georgia Project : Anor PLAZA City Mall Country : Uzbekistan Project : PTC Business Center Country : Russia Project : Hotel Sahid Zarafshan Country : Uzbekistan
Reference Projects(Factory) Project : Sasa Manado Country : Indonesia Project : Inkote Cikarang Country : Indonesia Project : B’lao Food Country : Vietnam Project : Peterpipe Country : Russia Project : Strada Fagului Plant Country : Romania
New Product (Under planning) 4
Classical type Type Model Features Classical type TCA401YH 142KW Heat pump ( 380-3-50 ) New appearance The ambient temp. of cooling operation can reach - 7 ℃. TCA401YH ETA : Mid 2023
High-efficiency type Type Model Features High-efficiency type TCA401YHE: TCA401YHE 142kW/175kW, Heat pump ( 380-3-50 ) New appearance , dual-C type heat exchanger. Two compressors , two inverter fan Operating range: Cooling : Chilled water outlet temp. 5~20 ℃ Ambient temp. -20~48 ℃ Heating : Hot water outlet temp. 30~60 ℃ Ambient temp. -30~48 ℃ 5.Unit dimension(mm): 2250L*1150W*2255H TCA201YHE is waiting for the next step of development . TCA401YHE ETA : The first half of 2023
Low temperature strong heat type Type Model Features Low temperature strong heat type TAS500BHE 500KW Heat pump ( 380-3-50 ) Operating range: Cooling : Chilled water outlet temp. 5~20 ℃ Ambient temp. 5~48 ℃ Heating : Hot water outlet temp. 30~60 ℃ Ambient temp. -30~48 ℃ TAS500BHE ETA : The first half of 2023