Analysis Case Study ( Industria Business Incubator in Bankig)
Size: 62.6 MB
Language: en
Added: May 04, 2024
Slides: 29 pages
Slide Content
Banking – United Kingdom
Banking – United Kingdom
Banking – United Kingdom
Architects: Haworth Tompkins. Area: 11400 m². Year: 2023. Lead Architects: Graham . Haworth, Hugo Braddick. City: Barking. Country: United Kingdom.
Architect: Haworth Tompkins. Area: 11400 m². Year: 2023. City: Barking. Country: United Kingdom. Brief 45 57 1593 3 1 65 2 Units comprising of 20 Industrial warehouse units and 25 creative space units. Sq meter smallest unit size. Sq meter largest singular unit size. Goods lifts. Vehicular ramp to 1st and 2nd floor. Car parking spaces, including EV charging points. Passenger lifts.
Haworth Tompkins A large percentage of their architectural designs are cultural centers Punchdrunk 2022 Battersea 2018 Every man 2013
Haworth Tompkins A large percentage of their architectural designs are cultural centers Chichester 2014 National Theatre 2015
Haworth Tompkins A large percentage of their architectural designs are cultural centers Peter Hall 2018 The Shed 2013 Industrial 2023
Location 4 minutes to the A13. 6 minutes to the north circular. 15 minutes to the M25. 16 minutes to Blackwall Tunnel. Links to the El3 bus route on long Reach Road and river Road. El3 bus route goes directly to Barking Station. 11 minutes drive to Barking station. 5 minutes five to Barking riverside Station. 20 minutes drive to London City Airport. The site is in the heart of the industrial River Road Employment Area, adjacent to the A13 and close to Barking Power Station - soon to host the relocated City of London Markets. Industria will provide a community of light industrial units and maker spaces within a modern, sustainable building capable of flexing and adapting to current needs. Banking, United kingdom.
Climate Average Rainfall (mm Graph for Barking)
Plans – Site plan 55.6 73 22.5 49 9 52 8
Plans G. Ground Floor North Block 6.8m clear height South Block 7.1m clear height One roller shutter door per unit Dedicated parking for each unit One WC per unit Industrial Warehouse Units North Block Sq meter Unit 1 464 Unit 2 317 South Block Sq meter Unit 3 327 Unit 4 283 Unit 5 263 Unit 6 259 Key: Café / Business Lounge Bike Store Bin Store Loading Bay Goods Lift Passenger Lift WC 1 1 2 2
Plans 1. First Floor North Block 7.1m clear height South Block 7.1m clear height At least one roller shutter door per unit Dedicated parking for each unit One WC per unit Key: Goods Lift Passenger Lift WC Industrial Warehouse Units North Block Sq meter Unit 7 459 Unit 8 485 Unit 9 457 Unit 10 349 South Block Sq meter Unit 11 334 Unit 12 437 Unit 13 379 Unit 14 163 Unit 15 175 1 1 2 2
2. Second Floor Creative Space Unit South Block 6 - 6.6m clear height At least one roller shutter door per unit Dedicated parking for each unit One WC per unit Key: Goods Lift Passenger Lift WC Creative Space Units North Block Sq meter Unit 16 234 Unit 17 226 Unit 18 231 Unit 19 191 Unit 20 76 Unit 21 153 Unit 22 158 Unit 23 27 Unit 24 17 Unit 25 45 Unit 26 43 Car parking Five unisex communal WCs Communal kitchen Communal Kitchen Industrial Warehouse Units South Block Sq meter Unit 27 335 Unit 28 436 Unit 29 379 Unit 30 164 Unit 31 175 North Block 3.5m clear height Industrial Warehouse Unit Plans 1 1 2 2
3. Third Floor Creative Space Unit Key: Goods Lift Passenger Lift WC Creative Space Units North Block Sq meter Unit 32 114 Unit 33 116 Unit 34 110 Unit 35 97 Unit 36 115 Unit 37 113 Unit 38 190 Unit 39 91 Unit 40 76 Unit 41 76 Unit 42 83 Unit 43 74 Unit 44 78 Unit 45 77 Car parking Five unisex communal WCs Communal kitchen Communal Kitchen North Block 3.5 – 4.2m clear height Plans 1 1 2 2
Vertical Circulation
Car circulation People access Horizontal Circulation Main access for cars and people
Interior & Exterior shots
Elevations West elevation East elevation The corrugated metal paneling of the interior deck façades features a playful silver and yellow checkerboard pattern, inspired by the building’s helical vehicle ramp logo
Elevations North elevation - back of house South elevation – back of house
Sections Key: Light Industrial Unit Flatted Factory Unit Barking Industrial : Section 01
Sections Key: Light Industrial Unit Flatted Factory Unit HGV Loading Bay Barking Industrial : Section 02
Sective 2,000 sqm roof solar panels = 297,198 kWh annually. Industria has been designed to support staff wellbeing, improve energy efficiency and reduce carbon emissions. Targeting BREEAM Excellent standard and an A+ EPC rating.
Sustainability Industria has been designed to support staff wellbeing, improve energy efficiency and reduce carbon emissions. Targeting BREEAM Excellent standard and an A+ EPC rating. Environment BREEAM ‘Excellent’ ) targeted) Social EPC Rating A+ (targeted) Electric Vehicle charging points 100% photovoltaic roof cover Cycle store LED lighting Great natural daylight throughout units Ground floor café and co-working lounge Communal top deck amenity with seating and break out space Feature green walls, landscaping and street level planting Supporting and strengthening the local industrial community in Banking 2,000 sqm roof solar panels = 297,198 kWh annually.
The entire façade was constructed using high-quality MCC panel systems. The building’s outer perimeter features pigmented precast concrete panels with a deep pebble texture on the ground floor Black metal cladding on the upper stories. Outside, green walls and planting have been introduced at deck ends and alongside street frontages adding biodiversity, shading, privacy and visual interest. Glass Metal Rain forced concrete van ramp Material and Structure are commonly found on commercial and industrial buildings , but they can also be used on residential properties. One of the main purposes of low-slope roofing is to provide efficient water drainage. The design allows water to run off easily instead of pooling on the roof’s surface, which can lead to leaks and structural damage over time. Additionally, low-slope roofing systems often include waterproofing membranes, insulation layers, and protective coverings such as gravel or asphalt to enhance durability and energy efficiency. Low slope roof structure
are commonly found on commercial and industrial buildings , but they can also be used on residential properties. One of the main purposes of low-slope roofing is to provide efficient water drainage. The design allows water to run off easily instead of pooling on the roof’s surface, which can lead to leaks and structural damage over time. Additionally, low-slope roofing systems often include waterproofing membranes, insulation layers, and protective coverings such as gravel or asphalt to enhance durability and energy efficiency. Material and Structure Every horizontal 30.5 cm = roof rises 2.55 cm vertically Low slope roof structure أحد الأغراض الرئيسية للأسقف منخفضة الانحدار هو توفير تصريف فعال للمياه . يسمح التصميم بتصريف المياه بسهولة بدلاً من تجمعها على سطح السقف، مما قد يؤدي إلى حدوث تسربات وأضرار هيكلية بمرور الوقت. بالإضافة إلى ذلك، غالبًا ما تشتمل أنظمة الأسقف منخفضة الانحدار على أغشية مقاومة للماء وطبقات عازلة وأغطية واقية مثل الحصى أو الأسفلت لتعزيز المتانة وكفاءة الطاقة. واحدة من المزايا الرئيسية هي فعالية التكلفة . بالمقارنة مع الأسقف شديدة الانحدار، تتطلب أنظمة الأسقف منخفضة الانحدار مواد أقل وعمالة أقل أثناء التركيب، مما يجعلها ميسورة التكلفة مقدمًا. بالإضافة إلى ذلك، يتيح تصميمها المسطح سهولة الصيانة والإصلاحات، مما يقلل من التكاليف على المدى الطويل. ميزة أخرى للأسقف منخفضة الانحدار هي تنوعها في التصميم . يمكن تخصيص هذه الأسطح لتناسب الأنماط المعمارية المختلفة وتستوعب وظائف البناء المختلفة. سواء كنت بحاجة إلى مساحة إضافية للألواح الشمسية أو معدات التدفئة والتهوية وتكييف الهواء فإن السقف منخفض الانحدار يوفر المرونة اللازمة لدمج هذه العناصر بسلاسة.
Plans – Master plan Key: Light Industrial Unit Reception Café Kitchen Office Store Bin Store Bike Store Plant Sprinklers Goods Lifts HGV Loading Bay Barking Industrial : Ground Floor Plan 1 1 2 2
Plans Key: Light Industrial Unit Goods Lifts Barking Industrial : First Floor Plan Key: Light Industrial Unit Flatted Factory Unit Goods Lifts Breakout Amenity Area Kitchen Wcs Barking Industrial : Second Floor Lower Plan 1 1 1 1 2 2 2 2