Anophthalmic socket

14,165 views 49 slides Jul 26, 2015
Slide 1
Slide 1 of 49
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49

About This Presentation

anophthalmic socket,post enuclation socket syndrome


Slide Content

SIVA TEJA CHALLA ANOPHTHALMIC SOCKET

Anophthalmia  absence of globe Microphthalmia  underdeveloped eye Cryptophthalmos    complete or partial failure of development of eyelids. It is usually associated with varying degrees of incomplete development of eyeball

anophthalmia Anophthalmia is absence of globe Congenital or acquired

Congenital anophthaloms Very rare condition optic vesicle fails to develop 0.2–0.6 per 10,000 births Many cases initially diagnosed as anophthalmos contain remnants of an underdeveloped eye, or vestigial eye tissue, and are more appropriately termed microphthalmos

causes Idiopathic/sporadic Inherited as dominant, recessive, or sex-linked Trisomy 13-15 Maternal infections or teratogenic exposure 75% associated with syndromes

Ocular Findings Orbital findings Small orbital rim and entrance Reduced size of bony orbital cavity Extraocular muscles usually absent Lacrimal gland may be absent Small and mal developed optic foramen Eyelid findings Foreshortening of the lids in all directions Absent or decreased levator function with decreased lid folds Contraction of orbicularis oculi muscle Shallow conjunctival fornix, especially inferiorly

Acquired anophthalmos After enuceation /evisceration/ exenteration

ANOPHTHALMIC SOCKET

DEFINITION D efined as an orbit not containing an eye ball, but with orbital soft tissues and eye rarely congenital but usually is acquired The most common cause is an enucleation of the globe The optimal time to achieve the best functional and cosmetic result for the anophthalmic patient is at the time of enucleation

ideal anophthalmic socket 1. A centrally placed, well-covered, buried implant of adequate volume , fabricated from a bio-inert material 2 . A socket lined with healthy conjunctiva and fornices deep enough to retain a prosthesis and to permit horizontal and vertical excursion of an artificial eye 3. Eyelids with normal position and appearance, as well as adequate tone to support a prosthesis 4. A supratarsal eyelid fold that is symmetric with the supratarsal fold of the contralateral eyelid 5. Normal position of the eyelashes and eyelid margin 6. Good transmission of motility from the implant to the overlying prosthesis 7 . A comfortable ocular prosthesis that looks similar to the sighted, contralateral globe and in the same horizontal plane

CHANGES associated

POST ENUCLEATION SOCKET SYNDROME Term introduced by tylers and collin Sequelae of an enucleation are orbital volume deficiency and changes in the orbital soft tissue architecture leading to the clinical picture of ‘post- enucleation socket syndrome (PESS) Clinical features : Enophthalmos An upper eyelid sulcus deformity Ptosis or eyelid retraction Laxity of the lower eyelid A backward tilt of the ocular prosthesis

typical features of a right post- enucleation socket syndrome (PESS ) are seen lateral view of the patient demonstrating a typical backward tilt to the prosthesis

left upper eyelid retraction and an upper eyelid sulcus defect same patient demonstrating lagophthalmos . examination of the socket reveals that superior fornix contracture is the cause of her lagophthalmos

Other changes Tear production and outflow may also diminish with time in the anophthalmic socket and may not become manifest for several years after the initial procedure socket discharge is common in an anophthalmic socket mucous secretion from the conjunctival goblet cells may increase, which is often interpreted as an infection by the patient.

MANAGEMENT

Complications and treatment Enophthalmos & superior tarsal sulcus deformity results from poor orbital volume result of inadequate volume replacement at the time of surgery or subsequently due to atrophy of fat and inferior migration of implant . Cont …..

Most socket reconstructive surgeries are required to address the following problems: 1. A volume deficit following loss of the globe 2. Contracture of the socket 3. Orbital implant exposure, extrusion, and malposition

orbital implant is typically placed at the time of evisceration or enucleation ocular prosthesis is fitted subsequently.

Fabrication, care, and maintenance of the artificial eye

Non integrated Semi integrated Fully integrated Expandable implants IMPLANTS

prosthesis

Modified impression technique

TREATMENT OF VOLUME DEFECIT

Treatment of enophthalmos : placement of a secondary orbital implant if no implant was placed at the time of primary surgery Dermis fat graft (DFG) is an option in patients with associated surface contracture Orbital floor implants. Autologous  bone grafts Non autologous medpor Treatment of superior sulcal deformity implantation of fascia lata / sclera / bone / fat/ alloplastic material in upper eyelid

Dermis fat graft

DERMIS FAT GRAFT TO UPPER LID

Lax socket and inferior fornix shelving : Lax socket results from shifting of tissues within the orbit With time there is involutional relaxation of the supporting tissues of the inferior eyelid the weight and pressure effect of the prosthesis causes laxity of the lid resulting in inability to retain the prosthesis Treatment Use prosthesis of optimal weight and size Lateral tarsal strip fornix formation sutures to increase the depth of inferior fornix

FORNIX DEEPENING SUTURES

A nophthalmic ptosis I nadequate implant size M igration of the orbital implant P oorly fit prosthesis L axity of the fibrous connective tissue O rbit trauma from the original injury/surgery S enile dehiscence of the levator aponeurosis Frequent manipulation of the eyelids to insert and remove the artificial eye also stretches the upper eyelid tissues  drooping eyelid.

Treatment The mechanisms producing anophthalmic ptosis are mutifactorial and should be assessed carefully Small amounts of ptosis may be managed by modification of the prosthesis correction of socket volume deficiency should be considered prior to levator surgery Once the other factors contributing to ptosis in the anophthalmic socket have been addressed tightening of the levator aponeurosis can be done

Anophthalmic ectropion Ectropion of the lower eyelid is common in the anophthalmic socket and is frequently associated with significant lower eyelid laxity A large or heavy prosthesis or frequent prosthesis removal may contribute to a stretching of the medial and/or lateral canthal tendons rotation of the orbital contents inferiorly and anteriorly contribute to a shallow inferior fornix, tilt of the prosthesis, and lower eyelid ectropion

Treatment If the prosthesis is >5 years old, a new one may be required If the prosthesis is large then a thinner or lighter prosthesis may help correct the eyelid malposition Tightening the lateral or medial canthal tendo n may remedy the situation Correction of eyelid retraction by recession of IR/ grafting of mucus membrane tissue in inferior fornix

Other complications

Exposure and Extrusion of Implant Implant exposure may occur with any type of implant or at any time (early versus late) may lead to implant extrusion or explantation

Porous orbital implants have a lower incidence of implant exposure than traditional nonporous implants Factors predisposing  closing the wound under tension poor wound closure techniques Infection mechanical or inflammatory irritation from the speculated surface of the porous implant Delayed ingrowth of fibrovascular tissue with subsequent tissue breakdown

Preventive measures : proper placement of the implant within the orbit followed by a two-layered closure of anterior Tenon’s capsule and conjunctiva The rectus muscles are then attached to the wrapped implant Treatment : If few weeks, No infection,simple reclosure or with a patch graft ( e.G. , Sclera, temporalis fascia) is required If infection is suspected and treated vigorously with topical and systemic antibiotics, an extrusion and removal of the implant may be avoided.

beyond 4–6 months, If non porous implant,The defect should not be closed, and secondary orbital implant surgery should be arranged If porous, exposure <3mm >3mm Treat conservatively Wait 8 weeks for spontaneous closure no Close with scleral patch graft surgical repair is indicated Using sclera patch graft or temporalis fascia patch graft

contracted socket A contracted socket is defined as the shrinkage and shortening of orbital tissues causing a decrease in depth of fornices and orbital volume ultimately leading to inability to retain prosthesis. Guibor has classified clinically contracted socket into 4 morphological types

Causes Etiology related ・Alkali burns ・Radiation therapy Surgery related Fibrosis from the initial injury Poor surgical techniques during previous surgeries - enucleation /evisceration with extensive dissection of orbital tissue Excessive sacrifice of the conjunctiva and tenons capsule Traumatic dissection within the socket leading to scar tissue Multiple socket operations Cont ……

Site related Poor vascular supply Severe ischemic ocular disease in the past Cicatrizing conjunctival diseases Chronic inflammation and infection Implant and prosthesis related Implant migration Implant exposure Not wearing a conformer/prosthesis Ill fitting prosthesis