base isolation in Japan workshop N.Macedonia

aleks970184 20 views 72 slides Jun 04, 2024
Slide 1
Slide 1 of 72
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53
Slide 54
54
Slide 55
55
Slide 56
56
Slide 57
57
Slide 58
58
Slide 59
59
Slide 60
60
Slide 61
61
Slide 62
62
Slide 63
63
Slide 64
64
Slide 65
65
Slide 66
66
Slide 67
67
Slide 68
68
Slide 69
69
Slide 70
70
Slide 71
71
Slide 72
72

About This Presentation

base isolation


Slide Content

SEISMIC ISOLATION APPLICATIONS IN
JAPAN
Akira Wada
Professor Emeritus, Tokyo Institute of Technology
North Macedonia-Japan Workshop
February 9-10, 2023

We hope we learn and discuss
many things withNorth Macedonia.
North Macedoniaand Japan are friends for a long time.

KumamotoEarthquake 20160414

Returnto1995 and 2011

On January 17, 1995
Akira Wada

KobeGreatEarthquake
Turkish Association for Seismic
Isolation
Akira Wada

Kobe earthquake at 1995
Akira Wada

株式会社新井組 1995年技術研究報告集より
Kobe Earthquake 1995
Akira Wada

株式会社新井組 1995年技術研究報告集よりAkira Wada

株式会社新井組 1995年技術研究報告集より
Perfectly Demolished after
1995 Earthquake
Akira Wada

All trucks were
bringing huge
garbage
produced from
collapsed
buildings and
demolished
buildings.

East Japan Earthquake at2011
Akira Wada

-1 -
b)集合住宅の被害分析
b1)建物の概要
検討対象の建物は仙台市に所在する1978年建築,11階建て,鉄骨鉄筋コンクリート(SRC)
構造の集合住宅である。建物の所在地を図-2.1.2.2.13に,全景写真を写真-2.1.2.2.34に示す。
また,図-2.1.2.2.14は建物の1階平面図を示す。建物は桁行(南北方向)約71m,梁間(東西
方向)約27mの対称な平面形状で,東棟と西棟が建物中央と端部で廊下を介して連結されている。
構造形式は桁行方向がラーメン構造,梁間方向が耐震壁付きラーメン構造である。ただし,桁行
方向では構造躯体と切り離されていない非構造壁が用いられていた。構造設計図による使用材料
は,コンクリートが設計基準強度21/mm
2
,鉄筋がSD295Aである。

図-2.1.2.2.13 所在地 写真-2.1.2.2.34 建物の北西面全景


図-2.1.2.2.14 1階平面図



観測点
建物位置
約2.7km 12 story Steel Concrete Apartment
Building of Sendai-City
Courtesy of Prof. Yasushi Sanada, Osaka University
Akira Wada

-3 -

写真-2.1.2.2.35 非構造壁の損傷

表-2.1.2.2.5 被災度区分判定結果
階数 耐震性能残存率R(被災度)
11F 86.9%(小破)
10F 95.4%(軽微)
9F 94.6%(小破)
8F 93.1%(小破)
7F 74.9%(中破)
6F 70.6%(中破)
5F 57.1%(大破)
4F 56.3%(大破)
3F 50.0%(大破)
2F 47.1%(大破)
1F 58.8%(大破)

b3)平面フレーム解析による性能評価と地震応答評価
建物のY3,Y4フレームの構造詳細や支配床面積が近似するため,Y4フレームのみを対象とす
る平面フレーム解析を行った。建物のモデル化方法は下記の通りである。

[建物のモデル化]
・柱,梁は非線形の曲げ特性,線形の軸方向特性(ただし,梁では考慮しない),せん断特性を有
する線材に置換する。
・柱,梁の曲げ特性はTakedaモデルにより表現する。
・柱,梁の曲げ降伏変形角は0.0066(=1/150)rad.とする。
・非構造壁は考慮しない。
・床は剛床を仮定する。
・支持条件は柱脚固定支持とする。
12 story Steel Concrete Apartment
Building of Sendai-City
Courtesy of Prof. Yasushi Sanada, Osaka University
Akira Wada

-2 -
b2)被害の概要と被災度区分判定
建物の被害は桁行方向が相対的に大きかったため,建物の対称性も考慮し,西棟の桁行方向(Y3,
Y4ラーメン)のみ被災度区分判定のための現地調査を行った。損傷の調査対象は主要構造部材で
ある柱,梁に加え,非構造壁とした。図-2.1.2.2.15にY3ラーメンの東側,Y4ラーメンの西側
のひび割れ図を示す。主要構造部材では柱の損傷は1階脚部を除き軽微であり,梁端部の損傷が
支配的であった。よって,建物は梁降伏先行の全体降伏機構を形成したと考えられる。ただし,
柱,梁の損傷は最大でも損傷度Ⅲ(ひび割れ幅1.5mm程度)と比較的小さかった。一方,非構造
壁には写真-2.1.2.2.35に示すような大きな損傷が見られた。表-2.1.2.2.5に被災度区分判定
を行った結果をまとめる。ただし,Y4ラーメンの非構造壁は長さが約500mmと比較的短いこと
から無視し,Y3ラーメンの外壁のみを考慮した。また,前述のように主要構造部材の損傷は主に
梁に生じていたため,梁の損傷を柱の損傷に読み替えて評価した。同表より,最も被災度が大き
かったのは2階であり,R=47.1%(大破)と判定された。

Y3ラーメン(西側)
Y4ラーメン(東側)
図-2.1.2.2.15 Y3,Y4ラーメンのひび割れ図
X9
X1 X2 X3 X4 X6 X7 X8 X9 X10 X11 X12X5
X5
X5
X5
X9 X10 -2 -
b2)被害の概要と被災度区分判定
建物の被害は桁行方向が相対的に大きかったため,建物の対称性も考慮し,西棟の桁行方向(Y3,
Y4ラーメン)のみ被災度区分判定のための現地調査を行った。損傷の調査対象は主要構造部材で
ある柱,梁に加え,非構造壁とした。図-2.1.2.2.15にY3ラーメンの東側,Y4ラーメンの西側
のひび割れ図を示す。主要構造部材では柱の損傷は1階脚部を除き軽微であり,梁端部の損傷が
支配的であった。よって,建物は梁降伏先行の全体降伏機構を形成したと考えられる。ただし,
柱,梁の損傷は最大でも損傷度Ⅲ(ひび割れ幅1.5mm程度)と比較的小さかった。一方,非構造
壁には写真-2.1.2.2.35に示すような大きな損傷が見られた。表-2.1.2.2.5に被災度区分判定
を行った結果をまとめる。ただし,Y4ラーメンの非構造壁は長さが約500mmと比較的短いこと
から無視し,Y3ラーメンの外壁のみを考慮した。また,前述のように主要構造部材の損傷は主に
梁に生じていたため,梁の損傷を柱の損傷に読み替えて評価した。同表より,最も被災度が大き
かったのは2階であり,R=47.1%(大破)と判定された。

Y3ラーメン(西側)
Y4ラーメン(東側)
図-2.1.2.2.15 Y3,Y4ラーメンのひび割れ図
X9
X1 X2 X3 X4 X6 X7 X8 X9 X10 X11 X12X5
X5
X5
X5
X9 X10 West
Frame
East
Frame
Courtesy of Prof. Yasushi Sanada, Osaka University
Akira Wada

Christchurch before 2011
Earthquake
Akira Wada

Christchurch after 2011
Earthquake

WHY CHRISTCHURCH? Courtesy of Prof.Gregory MacRae
2010-2011 Earthquake Sequence
http://www.stuff.co.nz/the-press/news/christchurch-earthquake-2011/5282824/Quake-damaged-buildings-mapAkira Wada

Our responsibility and
mission were not satisfied
Akira Wada

Professors recommend
Ductile Frames
to students.
Akira Wada

“Designed to protect life in extreme
event,but damage is expected”
Prof. Stephen Mahinsaid.
Akira Wada

Protect people life,but damages of
so many buildings are expected.
Akira Wada

Ductility is Damage
Akira Wada

New Seismic Design
1. Human life have to be safe
2. Building can use after some repaired
3. Continuous Use just after earthquake
Akira Wada

Passive ControlIsolation Ductile
3 seismic structural systems
Akira Wada

Shosoinmore than 1300 years ago years

Shosoinmore than 1300 years ago years

Shosoinmore than 1300 years ago years

Seismic Isolated Hospital
Maximum displacement is 45cm
Akira Wada

Akira Wada

Akira Wada

Houses are
the base of people life
•3 requirements have to be satisfied.
1: Maintain function for continuous use
2: Repairable for building value itself
3: No collapse for human life
•Then, the seismic isolated structures
are needed for housing structures in
seismically prone countries.
Akira Wada

Apartment houses
around 10 story buildings
Akira Wada

Akira Wada

Akira Wada

Akira Wada

Akira Wada

Apartment houses
around 10 story buildings
•Design shear force of super structure <
0.08W to 0.15W
•Shear force response in isolated layer <
0.13W
•Floor response of super structure < 0.15G to
0.25G
•Displacement in isolated layer = 300-400mm
•Story deformation < 0.005*height
•Construction cost = Conventional cost or less
Akira Wada

Apartment
buildings
taller than
30 story
buildings
Akira Wada

Akira Wada

FramedCorewall
Big composite slab
(Halfprecast)
Shortspanbeam:
DiagonallyReinforcedConcrete
Heigh-strength
reinforcingbar
Steel Frame
Akira Wada

Akira Wada

Akira Wada

Akira Wada

Akira Wada

Apartment houses
taller than 30 story buildings
•Design shear force of super structure <
0.05W to 0.07W
•Shear force response in isolated layer <
0.05W to 0.07W
•Floor response of super structure < 0.07G to
0.25G
•Displacement in isolated layer = 300-350mm
•Story deformation < 0.005*height
•Construction cost < Conventional structure
Akira Wada

Seismic isolated
twin steel tall
building
in TITech
Akira Wada

2FL
7FL
14FL
20FL
RFL
M FL
(Base-Isolation)
1FLx
Uplift of Isolator
Capacity: +20mm
(h)
Seismic Isolated
Steel Tall Building
constructing in
TITech Now
4 Stepping Columns
Akira Wada

SENDAI (Sendai MT BLDG.)
Rubber bearing
Sliding bearing0100200300400
0
2
4
6
8
10
12
14
16
18
X [NS]方向
2011年東北地方太平洋沖
2005年宮城県沖
最大加速度(cm/s
2

階数
2011 Tohoku Earthquake
2005 Miyagi Earthquake
Maximum Acceleration
Story
Akira Wada

TOKYO (Yoyogi-Seminar HQ BLDG.)
Semi-Active Isolation System0 100 200 300
0
5
10
15
20
25
30
X(短辺)方向
最大加速度(cm/s
2

階数
免震層
Maximum Acceleration
Akira Wada

Building Structures
Primary Structure Seismic Members
(To Support Vertical Load)(To absorb earthquake energy)
= +
DamageControlledStructures
Akira Wada

鎖骨
Some kind of Sacrificefor Human Body
We have to learn good ideas from Nature
Akira Wada

A Bumper protecting people and Bus
Akira Wada

A Fuse protecting important PC
Akira Wada

Shaking table tests for RC frame
5.5m 5.5m 5.5m 5.5m
2.75m
Column: 45cm×60cm
( B×D )
Beam : 38cm×85cm
( B×D )
Test
Specimen
Akira Wada

Additional mass and flexibility
}
220 ton Mass
Spring simulating
flexibility of
upper story
RC Frame
Specimen
Shaking Table
Akira Wada

Introduction of column axial forces
5,500 mm
Column
600 mm
80 ton axial force
by post-tensioning
Beam
Soft spring washers
850 mm
2,750 mm
Akira Wada

Elevation view during test
Natural period of the system : T
1 = 0.6sec
220 ton Inertia Mass
Columns
Beam
Rubber bearings
Load cell
Shaking table
Device
Isolator
Akira Wada

Plan view during test
Natural period of the system : T
1 = 0.6sec
220 ton Inertia Mass
on Isolation Rubber
ColumnsBeam
Rubber bearingLoad cell
Loading rig
Shaking Table
Akira Wada

Akira Wada

1987 to 1988
Buckling
Restrained
Braces
Akira Wada

Akira Wada

Many Unbonded Braces are
Installed
Akira Wada

Prof. Robert Park
Prof. Thomas Paulay
at Canterbury University
They introduced ductile moment
reinforced concrete frames in
earthquake prone countries, but
they said at that time:
Akira Wada

Prof. Robert Park
Prof. Thomas Paulay
at Canterbury University
They introduced ductile moment
reinforced concrete frames in
earthquake prone countries, but
they said at that time:
Ductility is not final goal.
Akira Wada

Conclusion 1/2
•A city is consisted of many buildings.
•People don't want to return to the
damaged building.
•When many buildings were demolished in
a city, we can not stay in the cityand we
can’t say that we make a resilient city.
Akira Wada

Conclusion 2/2
•We must consider not only resilience of a
building, but also resilience of a city
consist of many buildings.
•Then we must use seismic isolation and
passive controlled structures.
Akira Wada

We, structural engineers, have a mission
to make the world a better place to live.
Thank you very much for your attention.