BTech Sem 3 notes.pptxARARQQDWQEE2E2DSR4E WR3RD3 V
2021firkeKimaya
126 views
147 slides
Sep 17, 2024
Slide 1 of 147
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
About This Presentation
EGR
Size: 33.92 MB
Language: en
Added: Sep 17, 2024
Slides: 147 pages
Slide Content
1) slabs to cover 2) beams to support slabs and walls 3)columns to support beams 4) footings In a framed structure the load is transferred from slab to beam, from beam to column and then to the foundation and soil below it
What is concrete?
Here are some of the advantages of RCC construction: Materials used in RCC construction are easily available. It is durable and long lasting. It is fire resisting and not attacked by termites. It is economical in ultimate cost. The reinforced concrete member can be cast to any shape because of the fluidity of concrete. Its monolithic character gives much rigidity to the structure. Cost of maintenance is nil.
Here are some of its disadvantages: Scrap value of reinforced members is almost nil. Constant checking is required. Skilled labour is engaged in the work. The advantages of RCC outweigh its disadvantages. This is one construction technique that made construction very easy and brought a boom to the field of construction
C ement concrete 1:8:16:- is very low in strength • Used in foundation of walls of ordinary and single story building and used as base coat under floors and pavement. Cement concrete1:6:12:- low in strength • Used in foundation of two or three story buildings, used in foundation of abetments, piers and retaining walls and used as basecoat under taxi tracks, pavement and cement concrete road. Cement Concrete 1:4:8:- . medium strength • Used in foundation of multi story buildings, under foundation of RCC columns, stairs, raft, RCC wall and air strips and taxi tracks base coat. Cement Concrete 1:3:6:- medium strength Used in mass concrete, bed plates, concrete blocks, canal lining and chowkats hold fast etc. Cement Concrete 1:2:4:- good strength •Used in footings of columns and raft foundation, used in beams, slabs, columns, stairs and walls of ordinary, single story and temporary buildings and used in retaining walls, pavements, floors and bedplates etc. Cement Concrete 1:1.5:3 very good strength and • Important RCC structures, piles, arches, impermeable construction against water heads. This ratio of cement concrete is safe against earth quake.
M-5- 1:5:10 M-7.5 -1:4:8 M-10 - 1:3:6 M-15 - 1:2:4 M-20 - 1:1.5:3 M-25 -1:1:2 Nominal & Designed Concrete mix as per IS 456 Blended cement Portland Pozzolana
S TAGES IN STRUCTURAL DESIGN The process of structural design involves the following stages : 1) structural planning 2) action of forces and computation of loads 3) methods of analysis 4) member design 5)detailing , drawing and preparation of schedules
Structural planning positioning and orientation of column or columns position of beams spanning of slabs layout of stairs selecting proper type of footing the basic principle in deciding the layout of component members is that the loads should be transferred to the foundation along the shortest path
Steel Steel used in RCC- Mild steel, High tensile steel, cold twisted steel , high tensile steel Tensile steel – mild steel - 140 N/mm2 High Tensile steel - 190 N/mm2 Twisted High tensile steel..Fe415 - 230 N/mm2 ..Fe500 - 275 N/mm2
vertical compression member . subjected to axial compressive loads. Short Column: When the ratio of effective length to the least lateral dimensions of the column is less than 12 , then it is called a short column . ( or)When the ratio of effective length to the least radius of gyration is less than 45 , then it is called a short column Long Column: When the ratio of effective length to the least radius of gyration is greater than 45 , then it is called a long column. A long column is subjected to bending moment in addition to direct compressive stress. The load carrying capacity of a long column is less than a short column slenderness ratio (slenderness ratio increases then the capacity of the column decreases)
Column position for rectangular pattern building. LOCATION OF COLUMNS at or near the corners of a building and at the intersections of beams/walls . Select the position of columns so as to reduce bending moments in beams . When two columns are very near, then one column should be provided
ORIENTATION OF COLUMNS Avoid projection of column outside wall if possible. Orient the column so that the depth of the column is contained in the major plane of bending or is perpendicular to the major axis of bending. A B C D 1 2 3 4
depth of a beam - span/12 to span /15 breadth=depth X (1/2 to 2/3)
L Jn T Jn Cross Jn 300 X 300 Top most floor 300 X 300 350 X 350 Five and six 300 X 300 350 X 350 325 X 325 375 X 375 425 X 425 Three and Four 325 X 325 375 X 375 425 X 425 400 x 400 450 X 450 500 X 500 One and Two 400 x 400 450 X 450 500 X 500
Depth of the beam MEMBER SPAN/OVERALL DEPTH RATIO 1. PLINTH BEAM 15 TO 18 2. TIE BEAM 18 TO 20 3. FLOOR BEAMS 12 TO 15 4. GRID BEAMS 20 TO 30 Min width of the beam the width of the wall on top Depth of the slab The following thumb rules can be used ( Fe 415) • One way slab d=(l/22) to (l/28). • Two way simply supported slab d=(l/20) to (l/30) • Two way restrained slab d=(l/30) to (l/32) Cantilevered d = (l/7) to (l/10) In any case of the above, the thickness should not be less than 100mm
Helical Reinforcement (spirals) The diameter of helical bars should not be less than 1/4 th the diameter of largest longitudinal and not less than 6mm. The pitch should not exceed ( if helical reinforcement allowed) 75mm 1/6 th of the core diameter of the column Pitch should not be less than , 25mm 3 x diameter of helical bar - Pitch should not exceed (if helical reinforcement is not allowed) Least lateral dimension 16 x diameter of longitudinal bar (smaller) 300mm Position of lap shall be clearly mentioned in the drawing according to the change in reinforcement. Whenever there is a change in reinforcement at a junction, lap shall be provided to that side of the junction where the reinforcement is less.
CORRECT SPLICE DETAIL FOR COLUMN INCORRECT COVER CLOSE TIES @S/2 S-SPACING SLOPE 1:6
REDUCTION COLUMN BOTH SIDES INCORRECT CORRECT 3NO.CLOSE TIES SPLICE CLOSE STPS SPACIN <=75mm SLOPE 1:8 FROM BEAM BOTTOM 3NO.CLOSE TIES
1. PLINTH BEAM 15 TO 18 MEMBER SPAN/OVERALL DEPTH RATIO
FOOTINGS
BEAMS
BEAM FEW DEFINITIONS A beam is a structural element that is capable of withstanding load primarily by resisting against bending
OVER ALL DEPTH :- The normal distance from the top edge of the beam to the bottom edge of the beam is called over all depth. It is denoted BY ‘D’. EFFECTIVE DEPTH :- The normal distance from the top edge of beam to the centre of tensile reinforcement is called effective depth. It is denoted by ‘d’. CLEAR COVER :- The distance between the bottom of the bars and bottom most the edge of the beam is called clear cover. CLEAR COVER = 25mm OR DIA OF MAIN BAR, (WHICH EVER IS GREATER). EFFECTIVE COVER :- The distance between centre of tensile reinforcement and the bottom edge of the beam is called effective cover. EFFECTIVE COVER = CLEAR COVER + ½ DIA OF BAR. END COVER :- END COVER = 2XDIA OF BAR OR 25mm (WHICH EVER IS GREATER) NEUTRAL AXIS :- The layer / lamina where no stress exist is known as neutral axis. It divides the beam section into two zones, compresion zone above the netural axis & tension zone below the neutral axis.
Classification of beams According to shape: Rectangular, T, L, Circular etc According to supporting conditions : Simply supported, fixed, continuous and cantilever beams According to reinforcement : Singly reinforced and doubly reinforced
Thumb rules Beam (Sizes) Width (mm) Depth (mm) 200 X 300 230 X 300 250 X 400 210 X 450 X 450 Concrete - M 15, M20 Steel Main bars - 12,16,18,20,25,30mm hanger bars - 8,10,12 mm Stirrups - 6,8,10 mm Cover - minimum clear 25 mm or dia of largest bar Mild steel bars or Deformed or High yield strength deformed bars (HYSD) are used. HYSD bars have ribs on the surface and this increases the bond strength at least by 40%
Beam Beam – width of the beam is equal to width of the wall Depth of the beam is equal to 1/12 th (heavier loads) to 1/15 th (lighter loads) of span MEMBER SPAN/OVERALL DEPTH RATIO 1. PLINTH BEAM 15 TO 18 2. TIE BEAM 18 TO 20 3. FLOOR BEAMS 12 TO 15 4. GRID BEAMS 20 TO 30
Beam Bearing on brick wall Upto 3.5 m span - 200mm Upto 5.5 m span - 300mm Upto 7.0 m span - 400mm In general, the maximum spans of beams carrying live loads upto 4 kN /m2 may be limited to the following values.
Generally a beam consists of following steel reinforcements: reinforcement at tension and compression face. Shear reinforcements in the form of vertical stirrups and or bent up longitudinal bars are provided. Side face reinforcement in the web of the beam is provided when the depth of the web in a beam exceeds 750 mm. Reinforcement in beam
Beam design The max area of tension reinforcement not to exceed 0.04bD
The max area of compression reinforcement not to exceed 0.04bD Side face reinforcement ,if depth of beam is more, not more than 300 mm or web thickness whichever is less
Max spacing 300 mm C/C <0.75 d for vertical stirrups
Spacing of reinforcemnt bars The horizontal distance between parallel main bars should not be less than the greatest of the following Diameter of the bar if the bars are of equal size Diameter of the largest bar if the bars ar of unequal size 5 mm more than the nominal size of course aggregate Nominal cover Mild - 25mm Modereate - 30 mm Severe - 45 mm Extreme - 50 mm Very extreme - 75 mm Lap - 45 to 50 times dia of bar Development length - 50- 60 times dia of bar
Simply supported beam Simply supported beam with curtailed bar L/10 L/10
Fixed beam
L/7 L/10
Continuous beam with simply supported ends top extra bars at continuous supports Continuous beam with fixed ends top extra bars at continuous supports
Beam fixed to column In plan
SLABS
Terminology Effective span of slab : Effective span of slab shall be lesser of the two 1. l = clear span + d (effective depth ) 2. l = Center to center distance between the support Depth of the slab The following thumb rules can be used ( Fe 415) • One way slab d=(l/22) to (l/28). • Two way simply supported slab d=(l/20) to (l/30) • Two way restrained slab d=(l/30) to (l/32 Cantilevered d = (l/7) to (l/10) In any case of the above, the thickness should not be less than 100mm L/D ratio based upon type of steel Fe 500, Fe 415 Fe 600 One end continuous, both end continuous
Load on slab The load on slab comprises of Dead load, floor finish and live load. The loads are calculated per unit area (load/m2). Dead load = D x 25 kN /m2 ( Where D is thickness of slab in m) Floor finish (Assumed as)= 1 to 2 kN /m2 Live load (Assumed as) = 3 to 5 kN /m2 (depending on the occupancy of the building)
Cover & spacing Nominal Cover : For Mild exposure – 20 mm For Moderate exposure – 30 mm However, if the diameter of bar do not exceed 12 mm, or cover may be reduced by 5 mm. Thus for main reinforcement up to 12 mm diameter bar and for mild exposure, the nominal cover is 15 mm Minimum reinforcement : The reinforcement in either direction in slab shall not be less than • 0.15% of the total cross sectional area for Fe-250 steel • 0.12% of the total cross sectional area for Fe-415 & Fe-500 steel. Spacing of bars : The maximum spacing of bars shall not exceed • Main Steel – 3d or 300 mm whichever is less Distribution steel –5d or 450 mm whichever is less Where, ‘d’ is the effective depth of slab . Note: The minimum clear spacing of bars is not kept less than 75 mm (Preferably 100 mm) though code do not recommend any value. . Maximum diameter of bar: The maximum diameter of bar in slab, shall not exceed D/8, where D is the total thickness of slab.
One way slab Two way slab Simply supported Simply supported Continuous Continuous Fixed ( Restrained) Fixed ( Restrained) Cantilevered With or without bent up bars With or without bent up bars Supported condition Cantilever Simply supported Fixed / continuous Slab type One way Two way One way Two way One way Two way Maximum span in meters 1.50 2.0 3.50 4.50 4.50 6.0
For reference BARS IN SHORTER DIRECTION WILL BE PLACED BELOW BARS IN LONGER DIRECTION
RCC Slabs whose thickness ranges from 10 to 50 centimetres are most often used for the construction of floors and ceilings. Thin concrete slabs are also used for exterior paving purpose.
Design of various types of slabs and their reinforcement For a suspended slab, there are a number of designs to improve the strength-to-weight ratio. In all cases the top surface remains flat, and the underside is modulated: Corrugated , usually where the concrete is poured into a corrugated steel tray. This improves strength and prevents the slab bending under its own weight. The corrugations run across the short dimension, from side to side. A ribbed slab , giving considerable extra strength on one direction. A waffle slab , giving added strength in both directions
Prefabricated concrete slabs are cast in a factory and then transported to the site ready to be lowered into place between steel or concrete beams. They may be pre-stressed (in the factory), post-stressed (on site), or unstressed. Care should be taken to see that the supporting structure is built to the correct dimensions to avoid trouble with the fitting of slabs over the supporting structure. In situ concrete slabs are built on the building site using formwork. Formwork is a box-like setup in which concrete is poured for the construction of slabs. For reinforced concrete slabs, reinforcing steel bars are placed within the formwork and then the concrete is poured. Plastic tipped metal, or plastic bar chairs are used to hold the reinforcing steel bars away from the bottom and sides of the form-work, so that when the concrete sets it completely envelops the reinforcement. Formwork differs with the kind of slab. For a ground slab , the form-work may consist only of sidewalls pushed into the ground whereas for a suspended slab , the form-work is shaped like a tray, often supported by a temporary scaffold until the concrete sets
Materials used for the formwork The formwork is commonly built from wooden planks and boards, plastic, or steel. On commercial building sites today, plastic and steel are more common as they save labour . On low-budget sites, for instance when laying a concrete garden path, wooden planks are very common. After the concrete has set the wood may be removed, or left there permanently. In some cases formwork is not necessary – for instance, a ground slab surrounded by brick or block foundation walls, where the walls act as the sides of the tray and hardcore acts as the base.
Span – Effective Depth ratios Excessive deflections of slabs will cause damage to the ceiling, floor finishes and other architectural details. To avoid this, limits are set on the span-depth ratios. These limits are exactly the same as those for beams. As a slab is usually a slender member the restriction on the span-depth ratio becomes more important and this can often control the depth of slab required in terms of the span – effective depth ratio is given by, Minimum effective depth = span/(basic ratio x modification factor) The modification factor is based on the area of tension steel in the shorter span when a slab is singly reinforced at midspan , the modification factors for the areas of tensions and compression steel are as given in the figure 2 and 4 of the code.
Solid Slab spanning in two directions When a slab is supported on all four of its sides, it effectively spans in both directions, and it is sometimes more economical to design the slab on this basis. The moment of bending in each direction will depend on the ratio of the two spans and the conditions of restraint at each support. If the slab is square and the restraint is similar along the four sides, then the load will span equally in both directions. If the slab is rectangular, then more than one-half of the load will be carried in the shorter direction and lesser load will be imposed on the longer direction. If one span is much longer than the other, a large portion of the load will be carried in the shorter direction and the slab may as well be designed as spanning in only one direction. Moments in each direction of span are generally calculated using co- efficients which are tabulated in the code. The slab is reinforced with the bars in both directions parallel to the spans with the steel for the shorter span placed farthest from the natural acis to five the greater effective depth. The span- efective depths are based on the shorter span and the percentage of the reinforcement in that direction.
What are Simply Supported Slabs? Before we discuss the technical design rules of Simply Supported slabs, lets just go through its definition and learn why they are named so… As the name suggests, simply supported slabs are supported on columns or stanchions. Simply supported slabs are classified as One way slabs and Two way slabs. One way slabs bend in one direction only and transfer their loads to the two support beams in opposite directions. Their main steel in on shorter span length. L/B ratio is generally less than 2.
Simply supported slabs don’t give adequate provision to resist torsion at corner to prevent corner from lifting. The maximum bending moment will be given if the slabs are restrained. But atleast 50% of the tension reinforcement provided at the mid span should extend to the support. The remaining 50% should extend to within 0.1Lx or Ly at the support as appropriate. RCC Slab Design depends on the on the dimensions of the slab after which the slab is termed as a one-way slab or a two-way slab… n the design of RCC structures, Column Design and Beam Design are to be done before we start with RCC Slab Design…
Basic Rules followed in the design of simply supported Slab Thickness of slab l/d ratio should be less than the following: Simply supported slab Continuous slab, l/d = 26 Cantilever slab, l/d = 7 In any case of the above, the thickness should not be less than 100mm Effective span Distance between centre to centre of support Clear span plus effective depth Minimum main reinforcement ≥0.15% total cross sectional area of slab – for MS bars ≥ 0.12% gross cross sectional area of slab – for HYSD bars Spacing of main bars The spacing or c/c distance of main bars shall not exceed following: Calculated value 3d 300mm
Distribution or Temperature reinforcement This reinforcement runs perpendicular to the main reinforcement in order to distribute the load and to resist the temperature and shrinkage stresses. It should be atleast equal to; 0.15% gross c/s of slab – for MS bars 0.12% gross c/s of slab – for HYSD bars Spacing of distribution bars The spacing or c/c distance of distribution bars shall not exceed the following Calculated area 5d 450mm Diameter of bars The diameter of the bars varies from 8mm to 14mm and should not exceed 1/8 th of the overall depth of the slab. For distribution steel, the diameter varies from 6mm to 8mm. Cover The bottom cover for reinforcement shall not be less than 15mm or less than the diameter of such bar.
STAIRCASE
Staircase G T N R W θ Flight and landing. Steps Rise-R Going-G=T-N Tread-T Nosing -N Le L1 L2 FLIGHT
Based on shape Straight stairs Dog legged stairs Open well or open newel stairs Geometrical stairs such as spiral, circular, etc. Free standing stair cases Straight SC Geometric SC Dog legged SC Transversely spanning SC
Rise (R) : 150mm to 180mm Tread (T) : 220 mm to300 mm- for residential buildings. Rise (R) : 120 to 150 mm Tread (T) : 250 mm to 300 mm – for public buildings [T + 2R] : Between 500 mm to 650 mm The width of the stair 0.8 m to 1 m for residential building and 1.8 m to 2 m for public building.
The width of the landing is equal to the width of stairs. The number of steps in each flight should not be greater than 12 The pitch of the stair should not be more than 38 degrees. The head room measured vertically above any step or below the mid landing shall not be less than 2.1 m.
Stair slab spanning longitudinally Supported on edges AE and DH (b) (ii) Clamped along edges AE and DH (c) (iii) Supported on edges BF and CG (d) (iv) Supported on edges AE, CG (or BF) and DH (e) (v) Supported on edges AE, BF, CG and DH (f)
Stair slab spanning transversely ( i )Slab supported between two stringer beams or walls (a) (ii) Cantilever slabs from a spandreal beam or wall (b) (iii) Doubly cantilever slabs from a central beam (Fig.9.20.5c)
Stair slab spanning transversely – Slab supported between two stringer beams
Stair slab spanning longitudinally Supported on edges AE and DH (b)
ROW OF CHAIRS 500 mm 500 mm GL Wall FOUNDATION GROUND FLIGHT MAIN STEEL # 12 @ 120 DIST. STEEL # 8 @ 200 150 L d =564 REINFORCEMENT FROM BM L d =564 FLOOR LEVEL LANDING FIRST FLIGHT R=160 T= 250 LAP L Landing and flight spans longitudinally
Y=0.3 l or L d LANDING BEAM 500 500 GL FOOTING GROUND FLIGHT FIRST FLIGHT MAIN STEEL # 12 @ 120 DIST. STEEL # 8 @ 150 LANDING BEAM 150 X l Y Y 150 INTERMEDIATE LANDING ROW OF CHAIRS X = 0.15 l or L d MAIN STEEL DS 150 L e Flight spans longitudinally on landing beams
Refer SP-34 and learn the details STRAIGHT STAIR CASE
WALL SYSTEMS
Concrete frame structures are strong and economical. Hence almost any walling materials can be used with them. Heavier options - masonry walls of brick, concrete block, or stone. when strong, secure, and sound-proof enclosures are required Lighter options - drywall partitions made of light steel or wood studs covered with sheeting material. when quick, flexible lightweight partitions are needed. When brick or concrete blocks are used, it is common to plaster the entire surface - brick and concrete - with a cement plaster to form a hard, long-lasting finish.
Masonry Walls concrete block walls, common thicknesses are 200mm(8"), 150mm(6") and100mm(4"). (excluding plaster) Solid Concrete Blocks Hollow Concrete Blocks Lightweight Aerated Concrete Blocks Flyash Concrete Block brick walls, common thickness is 230mm(9"), excluding plaster) run electrical, or any other wires or pipes in a brick wall, you have to first chase the wall.
Brick partitions, (solid or hollow) Clay block partitions, Concrete partitions, Glass block partitions, Wooden partitions, Straw board partitions, Plaster slab partitions, ( burnt gypsum or plaster of paris mixed with sawdust.) Metal partitions, Asbestos cement partitions, and Double glazed window. Fibre Cement Board AAC Blocks (Autoclaved aerated concrete ( AAC ), also known as autoclaved cellular concrete (ACC), autoclaved lightweight concrete (ALC), Glass fiber reinforced gypsum (GFRG) wall paneL Gypsum board partition Materials can be used in ways that express their fundamental character, or materials can be used in ways that conceal their fundamental character. good designers generally use the specific qualities of specific materials to make their work visually expressive
Beam Beam – width of the beam is equal to width of the wall Depth of the beam is equal to 1/12 th (heavier loads) to 1/15 th (lighter loads) of span (a)Basic values of span/effective depth ratios for spans up to 10m ( supporting condition ) Cantilever 7 Simply supported 20 Continuous 26 For spans>10m,valuesin(a)maybemultipliedby10/span in meters location MEMBER SPAN/OVERALL DEPTH RATIO 1. PLINTH BEAM 15 TO 18 2. TIE BEAM 18 TO 20 3. FLOOR BEAMS 12 TO 15 4. GRID BEAMS 20 TO 30
Backup depth of a beam can be approximately calculated as follows span/15 and breadth= depthX (1/2 to 2/3)
At least 1/3 of the + ve moment reinforcement in SIMPLE SUPPORTS & ¼ the + ve moment reinforcement in CONTINUOUS MEMBERS shall extend along the same face of the member into the support, to a length equal to Ld /3. (Ld-development length ) Use higher grade of concrete if most of the beams are doubly reinforced. Restrict the spacing of stirrups to 8″(200mm) or ¾ of effective depth whichever is less.(for static loads ) Whenever possible try to use T-beam or L-beam concept so as to avoid compression reinforcement . Use a min. of 0.2% for compression reinforcement to aid in controlling the deflection, creep and other long term deflections .
Slabs Based of shape: Square, rectangular, circular and polygonal in shape. Based on type of support: Slab supported on walls, Slab supported on beams, Slab supported on columns (Flat slabs). Based on support or boundary condition or end condition: Simply supported, Cantilever slab, Overhanging slab, Fixed or Continues slab. Based on use: Roof slab, Floor slab, Foundation slab. Basis of cross section or sectional configuration: Ribbed slab /Grid slab, Solid slab, Filler slab, Folded plate , Waffle slab, Corrugated slab Basis of spanning directions : One way slab – Spanning in one direction( Long span / short span >2) Two way slab _ Spanning in two direction