Chopper fed DC Motor Dr.P.Subha Karuvelam Professor (CAS)/EEE GCE, Tirunelveli
Advantages of Chopper Ripple content in the output is small. Peak/average and rms /average current ratios are small. This improves the commutation and decreases the harmonic heating of the motor. The pulsating torques are also less. The problem of power factor does not occur at all. The conventional phase control method suffers from a poorer power factor as the angle is delayed. This means that the current drawn by the chopper is smaller than in a ac/dc phase controlled converter. The circuit is simple and can be modified to provide regeneration. The control circuit is simple .
Basic Step-down chopper
Control Techniques Time Ratio Control (TRC) Pulse Width Control Current Limit Control (CLC) Variable frequency variable ON time Control
Steady State Analysis of TRC
Steady State Analysis of TRC
Steady State Analysis of TRC Duty Interval When
Steady State Analysis of TRC Free wheeling interval where When
Steady State Analysis of TRC
Steady State Analysis of TRC
Speed – Torque curve of DCM with TRC
Steady State Analysis of CLC
Steady State Analysis of CLC
4 quadrant operation of DCM
4 Quadrant control of Chopper fed DCM
4 Quadrant control of Chopper fed DCM Method 1 I & II Quadrant – Forward Motoring & Forward Regeneration Method 2 I & IV Quadrant - Forward Motoring & Reverse Regeneration Method 3
Method 1 Forward Motoring & Forward Regeneration I & II Quadrant S2 closed , S1 & S4 operated III & IV Quadrant S3 closed , S1 & S4 operated
I Quadrant – Duty Cycle S1 & S2 – ON
I Quadrant – Free wheeling S2 & D2 - ON
II Quadrant – Energy Storage Interval S4 & D4 - ON
II Quadrant – Energy Transfer Interval D3 & D4 - ON
II I II I II D3 D4 S1 S4 S2 D2 S4 D4 D3 D4 S1 S4 S2 D2 S4 D4 D3 D4
Method 2 I & IV Quadrant – Current - + ve , Voltage - I Quadrant: Duty Interval : S1 & S2 - ON Free Wheeling Interval: S2 & D2 – ON IV Quadrant Energy storage Interval: S2 & D2 - ON Energy Transfer Interval: D1 & D2 - ON
Method 3 All the switches are controlled simultaneously
Types of Choppers Type A Chopper or First–Quadrant Chopper Type B Chopper or Second-Quadrant Chopper T ype-C chopper Chopper T yp e -D Chopper Chopper T yp e - E chopper Chopper o r T w o - qu a drant t y p e-A o r T wo-Qu a dr a nt T yp e – B o r the F o u rt h -Qu a drant
Type A Chopper or First–Quadrant Chopper
When chopper is ON, supply voltage V is connected across the load. When chopper is OFF, v O = 0 and the load current continues to flow in the same direction through the FWD. The average values of output voltage and current are always positive. Class A Chopper i s a st ep-down chopper i n which power always flows form source to load. It is used to control the speed of dc motor. The output current equations obtained in step down chopper with R-L load can be used to study the performance of Class A Chopper
Type B Chopper or Second-Quadrant Chopper
When chopper is ON, E drives a current through L and R in a direction opposite to that shown in figure. During the ON period of the chopper, the inductance L stores energy. When Chopper is OFF, diode D conducts, and part of the energy stored in inductor L is returned to the supply. A ve r age output volt a ge i s positive a nd a verage out p ut current is negative. In this chopper, power flows from load to source. Class B Chopper is used for regenerative braking of dc motor. Class B Chopper is a step-up chopper.
Type-C chopper or Two-quadrant type-A Chopper
Class C C h opper is a co m bination o f Class A and Cla s s B Choppers. For first quadrant operation, CH1 is ON or D2 conducts. For second quadrant operation, CH2 is ON or D1 conducts. When CH1 is ON, the load current is positive. The output voltage is equal to ‘V’ & the load receives power from the source. When CH1 is turned OFF, energy stored in inductance L forces current to flow through the diode D2 and the output voltage is zero. Current continues to flow in positive direction. When CH2 is triggered, the voltage E forces current to flow in opposite direction through L and CH2 The output voltage is zero.
On turning OFF CH2, the energy stored in the inductance drives current through diode D1 and the supply Output voltage is V, the input current becomes negative and power flows from load to source. Average output voltage is positive Average output current can take both positive and negative values. Choppers CH1 & CH2 should not be turned ON simultaneously as it would result in short circuiting the supply. Class C Chopper can be used both for dc motor control and regenerative braking of dc motor. Class C Chopper can be used as a step-up or step-down chopper.
Type-D Chopper or Two-Quadrant Type –B Chopper
Class D is a two quadrant chopper. When both CH1 and CH2 are triggered simultaneously, the output voltage v O = V and output current flows through the load. When CH1 and CH2 are turned OFF, the load current continues to flow in the same direction through load, D 1 and D 2 , due to the energy stored in the inductor L. Output voltage v O = - V Average load voltage is positive if chopper ON time is more than the OFF time Average output voltage becomes negative if t ON < t OFF . Hence the direction of load current is always positive but load voltage can be positive or negative.
Type-E chopper or the Fourth-Quadrant Chopper
Class E is a four quadrant chopper When CH1 and CH4 are triggered, output current i O flows in positive direction through CH1 and CH4 , and with output voltage v O = V. This gives the first quadrant operation. When both CH1 and CH4 are OFF, the energy stored in the inductor L drives i O through D 2 and D 3 in the same direction, but output voltage v O = - V. Therefore the chopper operates in the fourth quadrant.