Cone Beam Computed Tomography.pptx

1,022 views 132 slides Dec 25, 2022
Slide 1
Slide 1 of 132
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53
Slide 54
54
Slide 55
55
Slide 56
56
Slide 57
57
Slide 58
58
Slide 59
59
Slide 60
60
Slide 61
61
Slide 62
62
Slide 63
63
Slide 64
64
Slide 65
65
Slide 66
66
Slide 67
67
Slide 68
68
Slide 69
69
Slide 70
70
Slide 71
71
Slide 72
72
Slide 73
73
Slide 74
74
Slide 75
75
Slide 76
76
Slide 77
77
Slide 78
78
Slide 79
79
Slide 80
80
Slide 81
81
Slide 82
82
Slide 83
83
Slide 84
84
Slide 85
85
Slide 86
86
Slide 87
87
Slide 88
88
Slide 89
89
Slide 90
90
Slide 91
91
Slide 92
92
Slide 93
93
Slide 94
94
Slide 95
95
Slide 96
96
Slide 97
97
Slide 98
98
Slide 99
99
Slide 100
100
Slide 101
101
Slide 102
102
Slide 103
103
Slide 104
104
Slide 105
105
Slide 106
106
Slide 107
107
Slide 108
108
Slide 109
109
Slide 110
110
Slide 111
111
Slide 112
112
Slide 113
113
Slide 114
114
Slide 115
115
Slide 116
116
Slide 117
117
Slide 118
118
Slide 119
119
Slide 120
120
Slide 121
121
Slide 122
122
Slide 123
123
Slide 124
124
Slide 125
125
Slide 126
126
Slide 127
127
Slide 128
128
Slide 129
129
Slide 130
130
Slide 131
131
Slide 132
132

About This Presentation

A 4 part seminar on 3D cbct technology for seminar presentations. with added technical details and considerations with differences between a CT technology.
Also it features the technical parameters ,uses and how it is considered useful in each departments of medicine and dentistry.


Slide Content

Moderator Prof (Dr) Vidya Ajila Department of Oral Medicine and Radiology Presenter Dr. Anand shankar sarkar CONE BEAM COMPUTED TOMOGRAPHY

CONTENTS Introduction History Terminologies CBCT vs CT Types of CBCT Equipment Basic Principles and Imaging technique Artefacts

Imaging Guidelines CBCT in Prosthodontics CBCT in Endodontics CBCT in Periodontics CBCT in Orthodontics CBCT in Maxillofacial surgery CBCT in Otolaryngology Limitations Conclusion References

INTRODUCTION Radiology is essential in dentistry for determining the presence and extent of disease. It also has a role in treatment planning, monitoring disease progression and in assessing treatment efficacy. ORAL AND MAXILLOFACIAL RADIOLOGY ‘A Speciality of denstistry and discipline of radiology concerned with the production and interpretation of images and data produced by all modalities of radiant energy that are used for the diagnosis and management of diseases, disorders and conditions of the oral and maxillofacial region’

In conventional X-ray imaging an object is irradiated by photons generated from an X-ray source and the transmitted photons are registered on a photographic plate. Since the X-ray attenuation of the irradiated object is proportional to its electron density, the X-ray intensity transmitted after traversing a region of lower density is greater than the X-ray intensity transmitted after traversing a region of higher density. The contrast of the radiographic image has been applied for diagnostic purpose. Need for a THREE DIMENSIONAL Imaging modality

Cone beam imaging technology is the three dimensional imaging modality specially designed for the maxillofacial region, commonly referred to as cone beam computed tomography (CBCT). The terminology “cone beam” refers to the conical shape of the beam that scans the patient in a circular path around the vertical axis of the head, in contrast to the fan-shaped beam and more complex scanning movement of multidetector-row computed tomography ( MDCT ) commonly used in medical imaging.

Wilhelm C Roentgen, Professor of Physics in Wurzburg, Bavaria, discovered X-rays during his experiments with cathode rays Another mathematical advancement that Hounsfield built on is the “Algebraic Reconstruction Technique,” which was formulated by Polish mathematician Stefan Kaczmarz The mathematical basis for CT was first discovered by Radon called “Radon transform” 1895 1937 1917 HistORY CT was invented in 1972 by British engineer Godfrey Hounsfield of EMI Laboratories, England and by South Africa-born physicist Allan Cormack of Tufts University. 1972

Dedicated head CT scanner - " Siretom “ produced by circa 1974 An early volumetric CT predecessor of CBCT, the dynamic spatial reconstructor , was developed by Robles RA in by the Biodynamics Research Unit at the Mayo Clinic. Late 1970s The first clinical CT scanners were installed between 1974 and 1976. The original systems were dedicated to head imaging only, but "whole body" systems with larger patient openings became available in 1976. CT became widely available by about 1980.

CBCT prototypes based on C-arms were demonstrated as early as 1983. The technology transfer of CBCT to dentistry. Attilio Tacconi and Piero Mozzo , developed a CBCT system for the maxillofacial region that was designed and produced by QR, Inc of Verona, Italy. 1983 1995 NewTom DVT 9000 became the first commercial CBCT unit marketed specifically to the dental market. (Europe). 1999 The Food and Drug Administration (FDA) approved the first CBCT unit for dental use in the United States — the NewTom DVT 9000 (Quantitative Radiology srl , Verona, Italy). March 8, 2001 FDA granted approval for production of CBCT by various manufactures 2003

TERMINOLOGIES Tomography Method of producing three dimensional images of internal structures, imaging sections or sectioning through the use of any kind of penetrating wave. The device used in tomography is called tomograph where as the image produced is called a tomogram. Hounsfield units (HU) Quantitative measure of the radiolucency of different materials in a CAT scan. Hounsfield units allow us to differentiate the relative densities of various biological structures. The Hounsfield scale ranges from air at -1000 HF, through water at 0 HF, up to +1000 HF for cortical bone, +400 for cancellous bone, and 2000-3000 for metallic structures.

DICOM : Digital imaging and communications in medicine. This is a standardized format given by the ACR /NEMA (American College of Radiology/National Electrical Manufacturers Association) to allow the digital transfer of data between various diagnostic-imaging equipment and software. Gray scale : The ability of a CBCT scan to display differences in attenuation. This parameter is called bit depth of the system and determines the number of shades of gray available to display the attenuation

Pixel : Picture + Element. Pixel represents the smallest single component of an image on a two-dimensional grid. Voxel : Volumetric form of pixel. The voxel adds the third dimension (3-D) to the digital image by adding the z-axis (depth) to the x-axis (width) and the y-axis (height). Stacks of these volumetric boxes of data allow 360 degrees of virtual manipulation of imaged objects.

Attenuation : The property of reduction of the intensity of an x-ray beam as it traverses matter. Attenuation coefficient : Measure of the quantity of radiation attenuated by a given thickness of an absorbing material. The linear attenuation coefficient : Symbolized by the Greek letter µ, is the fractional change in x ray intensity according to the thickness of the attenuating material because of interactions in a given material. Frame Rate : Speed with which the images are acquired.

Field of view : A rea of interest to be covered during the scanning procedure. Small field of view (also referred to as limited or focused fields of view): scan height and width less than 5 cm. Medium field of view (also referred to as dentoalveolar field of view): scan height 5–15 cm. Large field of view (also referred to as craniofacial field of view): scan height greater than 15 cm.

Small FOV CBCT units A small FOV means that high-resolution images with a spatial resolution down to 0.076 mm isotropic voxel size can be achieved at very low exposure to ionizing radiation and without extensive reconstruction times that would be expected with larger FOV systems due to the greater file sizes to be processed. A small FOV reduces the volume examined, and for which the practitioner is responsible to interpret. Small FOV systems concentrate on the dental arches or individual temporomandibular joints, the structures in which the average dentist is most familiar. Only a limited area is imaged. Cannot be used for imaging maxillofacial pathologies and trauma.

Types of CBCT Equipment CBCT systems can be categorized according to the orientation of the patient during image acquisition, the scan volume irradiated, or the clinical functionality. Patient Positioning Depending on the system employed, CBCT can be performed in three possible positions: Sitting Standing Supine.

Equipment that requires the patient to be supine has a larger physical footprint and may not be readily accessible for patients with physical disabilities. Standing units may not be able to be adjusted to a height to accommodate wheelchair bound patients. Seated units are the most comfortable; however fixed seats may not allow ready scanning of physically disabled or wheelchair bound patients. As scan times are often similar to or greater than those used with panoramic imaging, The most factor other than patient orientation is the head restraint mechanism used.

Scan Volume The dimensions of the FOV , or scan volume, are primarily dependent on the detector size and shape, beam projection geometry, and the ability to collimate the beam. The shape of the FOV can be either a cylinder or spherical. Collimation of the primary X-ray beam limits x-radiation exposure to the region of interest (ROI). Field size limitation ensures that an optimal FOV can be selected for each patient based on disease presentation and the region designated to be imaged.

Based on available or selected scan volume height, the use of units can be designed as follows: localized region (also referred to as focused, small field or, limited field)—approximately 5 cm or less, Single arch—5 cm to 7 cm, Inter-arch—7 cm to 10 cm, Maxillofacial—10 cm to 15 cm, Craniofacial—greater than 15 cm.

Multimodality Hybrid multimodal systems combine digital panoramic radiography with a relatively small-to medium- FOV CBCT system. This combination is now priced at a level similar to upper-level digital panoramic radiographic systems. Cost of CBCT detectors is highly dependent on size. The ProMax 3D CBVT ( Planmeca Oy, Helsinki, Finland) was the first to incorporate a small FOV 3D sensor to their ProMax digital panoramic line, which can be also be retrofitted to any of the prior ProMax digital models. Examples of other hybrid units are the Veraviewepocs 3D (J. Morita, Corporation, Kyoto, Japan), the Picasso Trio ( Vatech /E. Woo Corporation, Korea), and the Kodak Dental Imaging 9000 DS (Kodak Dental Imaging/ Practiceworks Atlanta, GA, USA)

NewTom 3G. Accuitomo 170 Scanora 3Dx CS 9300 (Carestream Health, Rochester, NY). Orthophos XG 3D (Sirona USA, Charlotte, NC).

i -CAT FLX (Imaging Sciences International, Hatfield, PA) NewTom 5G, Italy The SkyView CBCT scanner ( MyRay , Imola , Italy) Planmeca – Promax 3D (Finland)

CT Vs CBCT

Imaging Modalities Effective Dose Panoramic film 3-11 μ S Lateral cephalography 5 - 7 μ S PA cephalograph 5 - 7 μ S Occlusal film 5 μ S Full mouth series 3 0-80 μ S TMJ series 20-30 μ S CBCT Small FOV 48-652 μ S CBCT Large FOV 68-1073 μ S MDCT 534-2100 μ S

Patient to be placed stationar y between the x ray source and detector. The rotating platform to which an X-ray source and detector are present rotates at 360 degrees around the patient. Data will be acquisited based on a translate-rotate parallel beam geometry wherein pencil beams of X-rays were directed at a detector opposite the source and the transmitted intensity of photons incident on the detector was measured. Raw images will be processed and obtained on the viewing console. Basic Imaging technique

Components of CBCT image production (1) Acquisition configuration (2) Image detection (3) Image reconstruction (4) Image display

X-ray Generation The X-ray generators used in CBCT operates in a range of 80–120 kVp . Focal spot dimension of 0.5–0.8 mm similar to CT machines. The tube current is generally much lower than CT. X-ray Detection Two systems are currently used in CBCT. I mage intensifiers/charge-coupled device (II/CCD) and flat panel detectors ( FPDs ).

II/Charge-coupled Device They consist of an X-ray image intensifier, proper optics and complementary metal oxide semiconductor (CMOS) or CCD camera. The II/CCD detectors are large and bulky and most frequently result in circular-basis image areas rather than rectangular/cylindrical volumes. The main disadvantages of II/CCD detectors are geometric distortion and blurring. FPD FPD consists of an array of hydrogenated amorphous silicon thin-film transistors or CMOS arrays. The silicon matrix is covered by a X-ray scintillator layer, which results in an indirect X-ray detection process. X-rays are detected indirectly by means of a scintillator such as thallium-doped cesium . X ray / Image Detectors

To be continued in p-ii..

CONE BEAM COMPUTED TOMOGRAPHY Department of Oral Medicine and Radiology Moderator Prof (Dr) Vidya Ajila Presenter Dr. Anand shankar sarkar

CCD Vs FPD Baba R, Konno Y, Ueda K, Ikeda S. Comparison of flat-panel detector and image-intensifier detector for cone-beam CT. Computerized medical imaging and graphics. 2002 May 1;26(3):153-8.

Incident X ray Beam X ray is converted light Electron Beam is formed Electron beam is converted to light Intensity of light is adjusted and converted to electrical signals Read out of the image Phosphor Screen Photocathode CMOS/CCD Camera STEPS IN IMAGE DETECTION IN II/CCD

Incident X ray Beam X ray is converted to visible light in photodiode array Electrical charge is produced, proportional to the energy of the incident x ray beam. Electron charge is received and stored Actual readout process is started Read out of the image Scintillator Photodiode Detection elements STEPS IN IMAGE DETECTION IN FPD Thin film transistor

mechanism The x-ray tube and the flat-panel detector are aligned and joined together in an imaging gantry which turns around the patient in a single, partial or complete rotation scan and record the digital data as data volume.

And it revolves..

Image Reconstruction Image reconstruction in CT is a mathematical operation that converts attenuation values per voxel from X-ray projection data to grayscale images. There are essentially two categories of reconstruction methods. Operations based on filtered back projection (FBP) - type of analytical reconstruction that is widely used because of their computational efficiency and numerical stability. Different FBP-based methods have been developed for all generations of CT data-acquisition geometries for CBCT large-area detectors. Analytical reconstruction techniques

These algorithms have recently been introduced in CT imaging, because they have many advantages compared with conventional FBP techniques. Important physical factors, including focal spot and detector geometry, photon statistics, X-ray beam spectrum and scattering, can be more accurately incorporated into iterative reconstruction, yielding lower image noise and higher spatial resolution compared with FBP. Iterative reconstruction may also show a significant dose reduction. In CBCT scanners, no control over the reconstruction method is provided to the operator. Iterative reconstruction techniques

Preprocessing stage After the multiple planar projection images are acquired, these images must be corrected for inherent pixel imperfections, variations in sensitivity across the detector, and uneven exposure. Reconstruction stage The corrected images are converted into a special representation called a sinogram - a composite image from multiple projection images. The horizontal axis of a sinogram represents individual rays at the detector, whereas the vertical axis represents projection angles. If there are 300 projections, the sinogram will have 300 rows. This process of generating a sinogram is referred to as the Radon transformation. The resulting image comprises multiple sine waves of different amplitude, as individual objects are projected onto the detector at continuously varying angles. Stages of Image Reconstruction

Sinogram Formation (Conversion and Correction) Weighting the projection Data Filtering of the Projected Data Back projection of weighted Data Reconstruction of image from the projected data BASIC IMAGE RECONSTRUCTION PROCESS

Image stitching Two or More consecutive scans are acquired, which are then merged (i.e. stitched) into one image. This can be carried out to combine two or more Small or Medium FOVs . Stitching of the image could be carried out through simple overlap or through automatic matching of the images using image registration.

Image Display The volumetric data of CBCT is displayed in the monitor/viewing console after data acquisition and can be viewed interactively. The default presentation offered by most visualization software is usually as a series of two-dimensional (2D) inter-relational images at a thickness defaulted to the native resolution in three orthogonal planes (axial, sagittal and coronal). CBCT imaging acquisition and visualization are usually performed on the same computer/workstation. Display software provides a number of visualization options, each directed toward highlighting specific components of the volumetric data set. The obtained data set can be reformatted and enhanced using third party softwares.

Multiplanar reformatting After reconstruction process a 3D matrix is created that can be viewed as a series of 2D cross-sectional images – axial (slices from top to bottom), sagittal (left to right) and coronal (anterior to posterior) views. Such MPR modes include oblique, curved planar reformation and serial transplanar reformation (providing cross-sections).

Oblique slicing: Nonorthogonal slicing of the CBCT images at any angle is possible because of the isotropic nature of the datasets to provide non-axial 2-D planar images referred to as multiplanar reformations. This function creates 2D images at any angle by cutting across a set of axial images, which help in evaluating particular structures (Impacted teeth, TMJ ). Curved slicing: This enables to trace the jaw arch to display a trace view, providing acquainted panorama like view.

Cross-sectional view: This function creates a set of successive cross-sectional images perpendicular to curved slice with the option of selecting the thickness and spacing. Such images are valuable in the evaluation of morphometric characteristics of alveolar bone for implant placement, the relationship of impacted mandibular third molar with mandibular canal, condylar surface and shape in the symptomatic TMJ or pathological conditions affecting the jaws.

Ray sum or ray casting Increasing the number of adjacent voxels in the display of any multiplanar image it gets ‘‘thickened’’. This process creates an image slab that represents a specific volume of the patient and is referred to as a ray sum. By using full thickness perpendicular ray sum images we can generate simulated projections such as lateral cephalometric images.

Three-dimensional volume rendering Allow the visualization of 3 dimensional data through integration of large volumes of adjacent voxels and selective display. (a) Indirect volume rendering - a complex process, requiring selecting the intensity or density of the grayscale level of the voxels to be displayed within an entire data set and provides a volumetric surface reconstruction with depth.

(b) Direct volume rendering - most common direct volume rendering technique is maximum intensity projection (MIP). MIP visualizations are accomplished by evaluating each voxel value along an imaginary projection ray from the observer’s eyes within a particular volume of interest and then representing only the highest value as the display value.

Image Quality F our fundamental parameters of image quality. S patial resolution C ontrast N oise A rtefacts

Spatial resolution The spatial resolution of an imaging system is its ability to discriminate objects of different attenuation at small separation distances. It is typically described as the spatial frequency (measured in line pairs per centimeter) that can be discriminated with a 10% detection of true contrast. Example : If 20 lines are seen in a 1 cm of image, then spatial resolution is 20. More the lp – More the Spatial resolution Normal Eye of O bservers can distinguish about 6 lp /mm without benefit of magnification. Intraoral film is capable of providing more than 20 lp /mm of resolution. CBCT sensors are capable of proving about 0.6 and 2.8 lp /mm

Temporal resolution It refers to the ability of an imaging system to discriminate sequentially acquired projection data separated by small time intervals. With higher temporal resolution, more projection datasets can be acquired over a fixed gantry rotation interval, thus improving contrast resolution. Contrast resolution Contrast resolution describes the ability of an imaging system to discriminate differences in tissue attenuation, as measured in HU. The low-contrast detectability in CBCT systems depends on both the dynamic range and temporal resolution of the detector as well as x-ray scatter and quantum noise.

Low High Why resolution is important ?

Image Noise Q uantum noise caused by the inherent random nature of the interactions happening during X-ray production and attenuation E lectronic noise caused by the conversion and transmission of the detector signal. Image Noise refers to the random variability in voxel values in an image.

High Low The scatter-to-primary ratios are about 0.01 for single-ray CT, 0.05–0.15 for fan-beam and spiral CT, About 0.4–2.0 in CBCT.

Artefacts in CBCT Imaging Beam related Artefacts Patient related Artefacts Scanner related Artefacts Foreign objects Beam Hardening Cone Beam related Faults Scatter Photon Depression Exponential edge gradient effect Image Noise and Poor soft tissue Contrast Factors deteriorating the image in CBCT Other deterioration factors

To be continued in p-iii..

CONE BEAM COMPUTED TOMOGRAPHY Department of Oral Medicine and Radiology Presenter Dr. Anand shankar sarkar Moderator Prof (Dr) Vidya Ajila

Why not hu in cbct ?? From experimental as well as clinical research, it can be seen that great variability of GVs can exist on CBCT images owing to various reasons that are inherently associated with this technique ( i.e.  the limited field size, relatively high amount of scattered radiation and limitations of currently applied reconstruction algorithms).  Pauwels R, Jacobs R, Singer SR, Mupparapu M. CBCT-based bone quality assessment: are Hounsfield units applicable?. Dentomaxillofacial Radiology. 2015 Jan;44(1):20140238.

Basis images.. Single projection images, known as “basis” images, are acquired at certain degree intervals, which are similar to lateral cephalometric radiographic images, each slightly offset from one another. The series of such basis projection images is referred to as the projection data, on which software programs incorporating sophisticated algorithms are applied to generate a 3D volumetric data set, which can be used to provide primary reconstruction images in all three orthogonal planes (axial, sagittal, and coronal). Kumar M, Shanavas M, Sidappa A, Kiran M. Cone beam computed tomography-know its secrets. Journal of international oral health: JIOH. 2015 Feb;7(2):64.

A rtefacts Image artefacts can be defined as regions in the image that are aberrant, that is, do not correspond to the real object, and are deterministic (i.e. non-random) with respect to the projection data. In CT, the term artifact is applied to any systematic discrepancy between the CT numbers in the reconstructed image.

The most prominent artifacts seen in CBCT images are beam hardening artifacts. Beam hardening artifact is seen because the mean energy of beam increases as the lower energy photons are absorbed more in comparison to higher energy photons. Highly absorbing materials such as metal function as a filter positioned within the object and they absorb the low energy photons. This shows effects in the distortion of metallic structures as a result of disturbance in the reconstruction process. Beam hardening artifact

Caused by : Heavy Metallic restorations, Metal posts in the root canals, etc.. Manufacture’s method of minimizing: B y using filtration, calibration correction, and beam hardening correction software. Operator’s method of minimizing : Avoid including potential areas to cause beam hardening within the FOV , Increasing the kVp

Cupping artifacts It occurs when x-rays passing through the center of a large object become harder than those passing through the edges of th e Object such as metal due to the greater amount of material the beam has to penetrate. Because the beam becomes harder in the center of the object, the resultant profile of the linear attenuation coefficients appears as a "cup". They are seen as a distortion of metallic structures as a result of differential absorption Streaks and dark bands They can be seen between two dense objects. More prominently seen in the axial planes and 3D reconstruction images

The cone beam projection geometry and the image reconstruction method produce three types of artifacts: Partial volume averaging : It occurs when the selected voxel resolution of the scan is greater than the spatial or contrast resolution of the object to be imaged. Partial volume averaging artifacts occur in regions where surfaces are rapidly changing in the z direction (e.g. in the temporal bone). Cone beam effect : This type of artifact is seen in the peripheral portions of the scan and is seen because of the divergence of X-rays in those areas. The outcome of cone beam effect is image distortion, streaks, and peripheral noise. Cone-shaped beam-related faults

Under sampling This is a type of aliasing artifact. It is seen when very few basis projections are provided for the reconstruction.

Exponential edge-gradient effect This effect is caused because of the sharp edges of the metallic crown borders producing high contrast, as it reduces the computed density value. As sharp edges of high contrast may commonly occur in the oral cavity, e.g. at metallic crown borders, this artifact also has to be considered in dental CBCT. Exponential edge-gradient effect ( EEGE ) with typical thin lines tangent to sharp edges (arrows) in the direction of the beam.

Photon deprivation This is a result of severe beam hardening, generally seen next to titanium implants or other heavy metal restorations. Due to the high density of metallic restorations, sufficient photons do not reach the detector and a complete void exists in the image, which is known as photon starvation. Photon deprivation effects can present as apparent "pseudo" fracture on axial images. Cone beam related artefacts are Corrected by the manufacturer : By Use of efficient reconstruction algorithms

Scattering is caused by those photons that are diffracted from their original path after interaction with matter. Most of the scattered radiation is produced omnidirectionally and is recorded by pixels on the cone beam area detector, which does not reflect the actual attenuation of the object within a specific path of the X-ray beam. The resultant outcome increases the image noise and reduces contrast. Amount of Scatter ∝ Reconstruction error Scatter Scatter refers to the off-axis low-energy radiation that is generated in the patient during image acquistion

Patient motion can cause faulty registration of data, which appears as unsharpness or double image in the reconstructed image. If an object moves during the scanning process, the reconstruction process does not account for that move. Patient related Artefact

Caused by : Patient movement - The lines along which the back projection do not correspond to the lines along which the attenuation had been recorded, because the object has moved during the acquisition, leading to misregistration / double images. Operator’s method for minimization : By using a head restraint, Using a scan time as short as possible.

These artifacts typically present as circular or concentric rings centered on the location of the axis of rotation. Caused by : malfunction of the detector due to faulty calibration or imperfections in scanner detection. Minimized by : Correction of Calibration Scanner related Artefact

The bite block may cast a shadow as per its shape and size, which may be confused as a foreign object. Metal foreign objects such as nose rings, earrings, clips, etc. can cast a shadow as a result of beam hardening. Caused by : Presence of Foreign objects in the imaging field. Operator’s method of minimizing : Instruct the patient to remove possible foreign objects in the imaging field. Foreign objects related Artefact

“ M issing value artifacts” If the object under study contains highly absorbing material, (e.g., gold prosthesis), then the signal recorded in the detector pixels behind that material may be close to zero or actually zero. A typical gold crown may be estimated to have at least 2–3 mm of thickness (when considering that the X-rays have to pass through both sides of it). This results in absorption of the mean energy of 90–97%. Consequently, no absorption can be computed and severe artifacts are induced as these zero entries are back projected into the volume. Caused by : High absorbing materials. Method of minimizing : Postprocessing image filters can help to correct raw data. Extinction Artefacts

Aliasing in CBCT lies in the divergence of the cone beam. In each projection, the voxels close to the source will be traversed by more recorded “rays” than those close to the detector. This causes aliasing which represents itself as line patterns ( moire patterns), commonly diverging toward the periphery of the reconstructed volume. Aliasing Artefacts

Review the patient’s medical and dental history along with performing a thorough clinical exam. Documentation of these procedures and justification that the excess radiation will result in a benefit outweighing the radiation risk must be included in the patient’s chart prior to prescribing a scan. Determine if standard 2D radiographic images show or do not show the area in question to the extent they need. Have basic knowledge and education in CBCT imaging to understand what the scan will or will not show. “ ADA recommends using evidence-based articles and continuing education courses to understand cone beam CT basics” American Dental Association Recommendations (2008) For Dental professionals ordering CBCT Scans

Prior to installing a CBCT unit, a health physicist should be consulted to determine the desired location of the machine has adequate shielding based on the machine perimeters ( kVp , mA, and exposure times). The health physicist will also ensure that the office is in compliance with federal and/or state radiation regulations After a CBCT unit is installed, proper training and education on safe use when performing scans must be achieved by all dental professionals who will be operating the machine. Adequate performance of quality control program including an evaluation interval to determine the machine is operating at the specified settings. The CBCT unit must be operated by either a licensed practitioner or certified radiologic operator. This will be different for every state/country. In certain states and countries, a CBCT may be either classified as a dental x-ray unit or a medical x-ray unit. For Dental offices and/or imaging centers that have a CBCT The imaging site should always be in compliance with ALARA principles. Offices with a cone beam CT unit should be continually learning about cone beam CT and radiation safety. Technology is consistently changing and the applications of this technology are also changing. An office must stay current to determine the best possible way to manage this new technology so as to aid in its patient care.

The referring practitioner is responsible to interpret the findings of the entire scan and generate a report of the findings. The practitioner is held to the same level as a board certified oral and maxillofacial radiologist. The scan should be interpreted by an oral and maxillofacial radiologist to aid the referring practitioner, an issue of licensure and malpractice insurance coverage needs to be determined. For Interpretation of CBCT Scans All CBCT scans should be evaluated by a dentist with training and education in CBCT interpretation. The entire captured CBCT scan must be interpreted and all findings put in the patient’s chart. It is the responsibility of the referring dentist to inform the patient of the findings both normal and abnormal.

Lechuga L, Weidlich GA. Cone beam CT vs. fan beam CT: a comparison of image quality and dose delivered between two differing CT imaging modalities. Cureus . 2016 Sep 12;8(9).

Summarized results from Elstrøm , et al., Garayoa , et al., and Kan, et al. showing the preferable system for various aspects

Replacement by dental implants demands accurate assessment of the implant site for the successful implant placement and to avoid injury to vital structures. Currently CBCT is the ideal choice of imaging, that has brought down implant failures by rendering accurate information about vital structures, height and width of the planned implant site, bone density and profile of the alveolus, while delivering low radiation exposure. P rosthodontics & Oral Implantology In 2000, the American Academy of Oral and Maxillofacial Radiology ( AAOMR ) published a position paper on the role of imaging in dental-implant treatment planning. “After reviewing the current literature, AAOMR recommends that some form of cross-sectional imaging be used for implant cases and that conventional cross-sectional tomography be the method of choice for gaining this information for most patients receiving implants.”

Ridge Morphology Buccolingual ridge pattern cannot be viewed on 2D radiographs, but CBCT provides with advantage of appreciating the type of alveolar ridge pattern present. Cross-sectional images - appearance of ridge patterns, loss of cortical plates, undulating concavities, etc. Evaluation of proximity to Vital structures CBCT aids in pre and post surgical evaluation of implants for assessement of the proximity of the implant to vital structures such as Mental foramen, Inferior alveolar Nerve Canal, Maxillary Sinus, Nasal Cavity. Angulation and Position of the Implant

CBCT Guided Implant Surgery Type and size of the planned implants, its position within the bone, its relationship to the planned restoration and adjacent teeth and/or implants, and its proximity to vital structures can be determined before performing surgery. This is possible with integration of CBCT scans with CAD/CAM technology and 3 D Printing. Computer generated surgical guides can be fabricated from the virtual treatment plan. These surgical guides are used by the implantologist to place the planned implants in the patient’s mouth in the same position as in the virtual treatment plan, allowing more accurate and predictable implant placement and reduced patient morbidity.

Virtual Implant Placement Fabrication of Surgical Guides

1 : Panoramic radiography should be used as the imaging modality of choice for initial evaluation. 2 : Use intraoral periapical radiography to supplement the preliminary information from panoramic radiography. 3 : Do not use cross-sectional imaging including CBCT as an initial diagnostic imaging examination. 4 : The radiographic examination of any potential implant site should include cross-sectional imaging orthogonal to the site of interest. 5 : CBCT should be considered as the imaging modality of choice for preoperative cross-sectional imaging of potential implant sites. AAOMR GUIDELINES

6 : CBCT should be considered when clinical conditions indicate a need for augmentation procedures or site development before placement of dental implants, Assessment of impacted teeth in the field of interest, Evaluation of prior traumatic injury. 7 : CBCT imaging should be considered if bone reconstruction and augmentation procedures have been performed to treat bone volume deficiencies before implant placement.. 8 : In the absence of clinical signs or symptoms, use intraoral periapical radiography for the postoperative assessment of implants. Panoramic radiographs may be indicated for cases with multiple implants. 9 : Use cross-sectional imaging immediately postoperatively only if the patient presents with implant mobility or altered sensation, especially if the fixture is in the posterior mandible. 10 : Do not use CBCT imaging for periodic review of clinically asymptomatic implants.

To be continued in p-iv..

CONE BEAM COMPUTED TOMOGRAPHY Department of Oral Medicine and Radiology Presenter Dr. Anand shankar sarkar Moderator Prof (Dr) Vidya Ajila

CBCT have made it the choice for exploring and handling Trauma, Imaging of midfacial and orbital fractures including dentoalveolar fractures, post fracture evaluation. Examination of the precise location and extension of pathologies such as odontogenic and non-odontogenic tumors, cysts of the jaws, Osteomyelitis, etc. Pathologic calcifications (e.g., tonsilloliths , lymph nodes, salivary gland stones) can be recognized in terms of location and distinguished from possibly noteworthy calcifications, such as those occurring in carotid artery. Pre operative assessment and localization of impacted teeth and odontomes . 3 D printed models derived from CBCT Scans can be used in simulation of surgeries / mock surgeries especially in orthognathic surgery cases. 3D reconstructions – Aid in patient education. Oral and Maxillofacial Surgery

CBCT images are also employed for pre- and post-surgical evaluation of bone graft receiver sites and to assess osteonecrotic changes of the jaws like medication-related osteonecrosis of the jaw. The morphologic appearances and degree of lesions in the para nasal air sinuses are predominantly well seen, although CBCT imaging does not provide suitable soft tissue contrast. CBCT derived images are helpful for pre-treatment assessments of patients with obstructive sleep apnea and to conclude suitable surgical method.

Paramedian fracture mandible – not visible on panoramic radiograph Coronal view (CBCT) sections taken in the paramedian area – visible fracture line.

Fracture of the Maxillary sinus – Multiplanar orthogonal slicing.

Multiple comminuted fractures involving NOE.

Displaced Condylar fractures

Mandibular Split fractures

CBCT is a very useful tool in diagnosing apical lesions CBCT used as a tool to assess whether the lesion was of endodontic or non-endodontic origin. CBCT superior to 2-D radiographs in detecting fractured roots. Inflammatory root resorptions. Extent of Cervical caries/abrasion. Tooth morphology and complex root canal morphologies. (Ex : Dens invaginatus, denticles) Multiplanar sections of CBCT is helpful in locating fractured or separated root canal instruments within the root canal. Endodontics

Identification of potential accessory canals in teeth with suspected complex morphology based on conventional imaging . Identification of root canal system anomalies and determination of root curvature . Diagnosis of dental periapical pathosis in patients who present with non - specific clinical signs and symptoms, who have poorly localized symptoms associated with an untreated or previously endodontically treated tooth with no evidence of pathosis identified by conventional imaging and in cases where anatomic superimposition of roots or areas of the maxillofacial skeleton is required to perform task - specific procedures . Diagnosis of non - endodontic origin pathosis in order to determine the extent of the lesion and its effect on surrounding structures . Intra - or post - operative assessment of endodontic treatment complications, such as overextended root canal obturation material, separated endodontic instruments, calcified canal identification and localization of perforations . Diagnosis and management of dentoalveolar trauma, especially root fractures, luxation and / or displacement of teeth and alveolar fractures . Localization and differentiation of external and internal root resorption or invasive cervical resorptions. AAE GUIDELINES

Oblique Coronal fracture

Cervical Resorption IOPA Sagittal/CS Axial Section

Periodontology Precise measurement of intra-bony defects. Analysis of Buccal and Lingual Cortices. Evaluate of furcation involvement, dehiscence, fenestration defects, and periodontal cysts. Assessment of postsurgical consequences of regenerative periodontal treatment. 3 D Reconstructions – Patient education about bone loss and periodontal status.

Localization of Ectopic, Impacted and Supernumerary Teeth. Assessment of Root Resorption, Both from Ectopically Erupting Teeth as Result of Orthodontic Treatment Side Effect. Quantitative and Qualitative measurement of Bony Dimensions in All Three Planes of Space. Evaluation of facial asymmetry. Evaluation of Pre and Post treatment assessment of arches. Evaluation of Cleft lip and Palate. Airway Analysis. Evaluation of Temporomandibular Joint. Orthodontics

1. Decision to order a CBCT scan should be based on the patient’s history, clinical examination and the presence of an appropriate clinical condition and assure the benefits to diagnosis and/or the treatment plan outweigh the potential risks of exposure to radiation, especially in the case of a child or young adult. 2. Use CBCT only when the clinical question for which imaging is required cannot be answered adequately by lower dose conventional dental radiography or alternate non-ionizing imaging modalities. 3. Do not use CBCT solely to facilitate the placement of orthodontic appliances such as aligners and computer bent wires or to produce virtual orthodontic models. 4. Design CBCT protocols to be task specific and to incorporate the imaging goal for the patient’s specific presenting circumstances. The protocol includes considerations of exposure (mA and kVp ), minimum, image-quality parameters (e.g. number of basis images, resolution), and restriction of the field of view ( FOV ) to visualize adequately the region of interest. 5. Do not perform a CBCT, if only 2D projected images derived from CBCT are to be used for diagnostic purposes. AAOMR GUIDELINES

One of the significant part of forensic dentistry is age estimation in which CBCT can be used efficiently. Enamel is generally resistant to alterations beyond normal wear and tear; conversely, the pulp dentinal complex displays physiologic and pathological changes with progressing age. Characteristically, to create skeleton for sex determination, personal identification. Digital forensic facial reconstruction algorithms verify these changes, extraction and sectioning of teeth if necessary, which is not always a practicable choice. CBCT, however, affords a non-invasive substitute. Evaluation of Maxillofacial can develop an array of facial profile based on the bony anatomy. Forensic Applications

Use of CBCT in an otolaryngology is to identify less complicated disease conditions quickly, cheaply and with lower radiation dose compared to a MDCT examination. Sinusitis, a common inflammatory disease involving the maxillofacial skeleton, is often of odontogenic origin. (Imaging of Sino nasal pathology in relation to dentition) CBCT not only provides diagnostic information of the status of extension of periapical lesions into the maxillary sinuses but also provides reliable information on the septa of the sinus and presence of exostoses. Otolaryngology Lata et al. (2018) – Opinion of ENT Specialists on CT Vs CBCT Diagnosis (1) Same as CT: 58 (53.1%) (2) Less than CT: 27 (25%) 3) More than CT: 25 (21.9%)

Paranasal Sinus Imaging, Sinonasal pathologies and Tooth Relations Pre- Endoscopic sinus surgery Maxillofacial and Nasal Trauma Temporal Bone Pathologies Middle/Inner Ear Malformation Cochlear Implant Visualization Ossicular Chain Malformations Obstructive Sleep Apnoea Airway Imaging Naso Lacrimal Gland - CBCT with Dacryocystography with some iodine contrast media for lachrymal canaliculi and sac is used to check blockade in nasolacrimal duct.

RECENT ADVANCES 3 D Stereophotogrammetry Stereophotogrammetry is based on photographing objects by a pair of configured cameras and combining photos taken from two different directions to create 3D models. CBCT Scanners with improved photographing aids in the assessment of soft tissue asymmetries.

Improved Resolution. Faster Scanning compared to the current CBCT Scanners. R educed Motion artefacts.

CBCT TECHNOLOGY already in clinical usage includes: 3 –Dimensional printing of implant stents using CAD/CAM. CBCT use in orthodontic analysis –skeletal analysis,dental analysis using anato-models,facial soft tissue analysis. CBCT for facial reconstruction. Surgical simulation and sleep apnoea management. Surface acquisition technology|virtual patient Intra-oral scanning and CBCT – complex and advanced orthodontic procedures.

Future advances in CBCT technology includes: Improved x-ray tube ,detector design efficiency and function. Larger variation in field of view, including single tooth imaging. Improvements in post processing reconstruction algorithms and merging dual energy photo scans to limit metal artifacts. Enhanced software application like merging intraoral/facial scans with CBCT and single tooth imaging. Simulate treatment strategy ,procedures and outcome. Merging robotic dynamic navigation tools with CBCT technology.

Hardware Improvements : Improved Algorithms for noise reduction. Improved Quality of sensors. Beam Configuration and Beam Geometry. Software Improvements : Artefact Reduction softwares . Softwares for cephalometric analysis of facial skeleton. (Dolphin, NemoCeph ) Software for demonstration of Visual Treatment Objectives.

SOFTWARE MANUFACTURER USES CS 3D CARESTREAM DENTAL, NY, USA USER FRIENDLY, IMAGE MANIPULATTION DOLPHIN 3D DOLPHIN IMAGING, CA, USA CEPHALOMETRIC ANALYSIS EASY GUIDE KEYSTONE DENTAL, MA, USA USER FRIENDLY, IMAGE MANIPULATTION PROCERA SOFTWARE NOBEL BIOCARE, USA IMPLANTS PLANMECA ORTHOSTUDIO PLANMECA OY, FINLAND ORTHODONTIC

Contrast-enhanced cone-beam computed tomography (CBCT) imaging is used for evaluating neurovascular stents and their relationship to the parent artery or vascular pathologies such as arteriovenous malformations (AVMs) and dural arteriovenous fistulas ( dAVFs ) in the context of surrounding anatomical structures. Used in Neurovascular Imaging of Brain Parenchyma.

Improved Image reconstruction algorithms are incorporated into CBCT imaging. For Image Guided Radio therapy.

Portable Used for Intra Operative Applications I ntraoperative imaging aids in the radiographic surgical assessment of the repair and fixation in the operating room, The use of intraoperative CBCT/CT can reduce the need for a second surgery, as the inadequacies of the surgery being performed can identified by CT imaging in the OT. The advent of intraoperative imaging methods have minimized the need for revision surgeries and thereby morbidity and ultimately improved clinical outcome

xCAT ENT CBCT – XORAN TECHOLOGIES

COMPARISON OF CBCT UNITS

CONCLUSION CBCT is a technical advancement of CT imaging that uses a cone beam acquisition geometry and FPD to provide relatively low-dose imaging with high isotropic spatial resolution acquired with a single gantry revolution. Efficient use of the X-ray beam in CBCT imaging produces a relatively low x-ray tube power requirement, which, along with flat panel detection and limited anatomic coverage, has facilitated the production of compact CBCT scanners suitable for use in an office-based setting. There is a Scope for further research on improving the limitations of CBCT, such as improvisation of the contrast resolution, reduction of image noise, Standardization of HU and exposure parameters.

Schulze, R., Heil, U., Gross, D., Bruellmann , D., Dranischnikow , E., Schwanecke , U., & Schoemer , E. (2011). Artefacts in CBCT: a review.  Dento maxillo facial radiology, 40 5, 265-73 . Bhoosreddy AR, Sakhavalkar PU. Image deteriorating factors in cone beam computed tomography, their classification, and measures to reduce them: A pictorial essay . J Indian Acad Oral Med Radiol 2014;26:293-7 . Nagarajappa AK, Dwivedi N, Tiwari R. Artifacts: The downturn of CBCT image. J Int Soc Prev Community Dent. 2015 Nov-Dec;5(6):440-5. Brüllmann D, Schulze RK . Spatial resolution in CBCT machines for dental/maxillofacial applications-what do we know today? Dentomaxillofac Radiol . 2015;44(1):20140204. Prashant P Jaju . CONE BEAM COMPUTED TOMOGRAPHY A Clinician’s Guide to 3D Imaging. Ist Edition. Jaypee Publishers. New Delhi. References

White S. C.,Pharoah , M. J. Oral radiology: Principles and interpretation. St. Louis, Mo: Mosby/Elsevier. 2009 Venkatesh E, Elluru SV. Cone beam computed tomography: basics and applications in dentistry. Journal of istanbul University faculty of Dentistry. 2017;51(3 Suppl 1):S102. Pavan Kumar T, Sujatha S, Yashodha Devi BK, Nagaraju Rakesh SV. Basics of CBCT Imaging. J Dent Orofac Research. 2013;13(1):49-55. Abramovitch K, Rice DD. Basic principles of cone beam computed tomography. Dent Clin North Am. 2014 Jul 1;58(3):463-84. Maret D, Vergnes JN, Peters OA, Peters C, Nasr K, Monsarrat P. Recent Advances in Cone-beam CT in Oral Medicine. Curr Med Imaging. 2020;16(5):553-564. Lechuga L, Weidlich GA. Cone beam CT vs. fan beam CT: a comparison of image quality and dose delivered between two differing CT imaging modalities. Cureus . 2016 Sep 12;8(9).

Venkatesh E, Elluru SV. Cone beam computed tomography: basics and applications in dentistry. J Istanb Univ Fac Dent. 2017 Dec 2;51(3 Suppl 1):S102-S121. Jacobs R, Salmon B, Codari M, Hassan B, Bornstein MM. Cone beam computed tomography in implant dentistry: recommendations for clinical use. BMC Oral Health. 2018 May 15;18(1):88. Alshehri AD, Alamri HM, Alshalhoob MA, Arabia S. CBCT applications in dental practice: A literature review. Oral and maxillofacial surgery. 2010;36(26.86). .P. Sarment, A.M. Christensen, The use of cone beam computed tomography in forensic radiology, Journal of Forensic Radiology and Imaging (2014). Lata S, Mohanty SK, Vinay S, Das AC, Das S, Choudhury P. "Is Cone Beam Computed Tomography (CBCT) a Potential Imaging Tool in ENT Practice?: A Cross-Sectional Survey Among ENT Surgeons in the State of Odisha, India. Indian J Otolaryngol Head Neck Surg. 2018 Mar;70(1):130-136. Erten O, Yılmaz BN. Three-Dimensional Imaging in Orthodontics. Turk J Orthod . 2018 Sep;31(3):86-94.

White S. C.,Pharoah , M. J. Oral radiology: Principles and interpretation; 2 nd south asia edition, St. Louis, Mosby/Elsevier. 2019 Pauwels R, Jacobs R, Singer SR, Mupparapu M. CBCT-based bone quality assessment: are Hounsfield units applicable?. Dentomaxillofacial Radiology. 2015 Jan;44(1):20140238. Kumar M, Shanavas M, Sidappa A, Kiran M. Cone beam computed tomography-know its secrets. Journal of international oral health: JIOH. 2015 Feb;7(2):64. Cone Beam CT and 3D imaging: A Practical Guide,Caruso P; 2014; Kindle Edition;Springer’s publishers. IAOMR position paper on CBCT ; extracted online from IAOMR website.

Thank you End