DCR - Development Control Regulations - Professional Practice - Architecture - NIT Trichy

4,831 views 43 slides Nov 24, 2018
Slide 1
Slide 1 of 43
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43

About This Presentation

DCR - Development Control Regulations - Professional Practice - Architecture - NIT Trichy


Slide Content

Developmental Control
Regulations
NIT TRICHY
101114001
101114007
101114042
101114044
101114026
101114030
101114009
101114012
101114047
101114049
101114050
101114051

Why is DCR
required?
Regulation is necessary to ensure planned development
DCR is must for every growing city because the area
immediately beyond the city limits is often a source of
health hazard to the city and generally under no strict
control of an efficient local authority
To control the private development as per the required
standards in relation to public health, safety and
convenience.
To encourage private interest along with public interest in
all aspects of development.
To prevent the conflicting demand and misuse of land.
To control and prevent overcrowding on land.
Development control is statutory in nature and the
planning authority has the power to punish the defaulters.

Types of DCR
Town and Country Planning Act
SLUM Clearance Act
Periphery Control Act
Land Acquisition Act
Zoning Regulations
Building Bye-laws

Zoning
Regulations
Allocation of land for specific purposes
Control of the use, height and construction of the building
Objective of zoning:-
1)The Town planner gets ample opportunity for designing
the future growth and development of the town.
2)Re-zoning if required for better uses of land by revising
their zoning ordinances can be possible.
3)The zoning affords proper co-ordination of various
public amenities such as transport facilities, drainage,
electric power, etc.
4)The zoning proves to be an effective instrument for
making any town planning scheme effective and
successful

Building Bye-
Laws
Freedom to builder or landlord
Rights of occupants
Rights of neighbor
Applicability of Bye-Laws:-
1)Additions and alteration to a buildings.
2)New construction.
3)Requirement of open space
Objectives
1)It becomes easier to pre-plan the building activities and provision of
bye-laws, give guidelines to the designing architect or engineer.
2)The building bye-laws prevent haphazard development without any
resemblance to the development of the area as a whole.
3)To provide open spaces, air breeze and afford safety against fire, noise,
smoke etc.
4)To control land development
5)Material types control

Bye-Laws
Typologies
Minimum sizes of plots
-Low Income Group =135-180 Sqm
-MIG=216-360 Sqm
-HIG= 486-972
Set backs
-Front / Rear Margin
-Side Margin
Min habitable area of rooms
Proportion of built up area to plot area
Plinth height
Floor height
Proportionate opening area
Projections
Stair
Compound
Materials and workmanship

DCR for
Hyderabad

DCR -
Hyderabad
(Cyberabad)

Maximum Height
Permissible
Depending On
The Road Width
TYPE A -SITES IN
OLD/EXISTINGBUILT-
UPAREAS/CONGESTEDARE
AS/SETTLEMENT
All Residential (other than
Group Housing) &Commercial
Buildings.
TYPE B1 -SITES INNEW
AREAS /APPROVED
LAYOUT AREAS
Non-High Rise(Residential)
Buildings including Group
Housing (Cellar and /or Stilt as
permissible + maximum up to 5
floors), Basic level social
amenities like Nursery
School,Primary School /
Religious Place /Clinic

Maximum Height
Permissible
Depending On
The Road Width
TYPE B2
High RiseBuildings/ Complexes,
Non High Rise Group
Housing(Cellars as applicable +
6floors),Group Housing with
more than100 units,
GroupDevelopment Scheme;
Middle school / Tutorial
institution / General Industry /
TYPE B3
General Degree and other non-
professional College /
Polytechnic, ITI; Professional
College Campus; Multiplex
Complexes, Shopping Malls
(above 4000sq.m), Hospitals of
more than 20 beds and all Non
High-Rise buildings up to 18 m

Introduction Of
Restrictions Of
Building Activity
For The Following
Areas
Railways
DistancefromRailwaypropertyboundarytothebuilding shall be
minimum 30m or as per NOC given by Railway Authority.
Airport
For Building activity within the Restricted Zone / Air Funnel Zonenear
the airport, necessary clearance from theconcerned Airport
Authority shall beobtained.
The building heights and other parameters shall be regulated as per
the stipulations of the Airport Authority of India.
In respect of any land located within 1000m from theboundary of
Military Airportno building is allowed exceptwith prior clearance
from the concerned airport authority with regard to building height
permissible and safe distanceto be maintained between the building
and boundary of theaerodrome.
DefenseEstablishments
In case of Sites within 500m distance from the boundary of Defense
Areas / Military Establishments prior clearance of Defense Authority
shall be obtained.

DCR for
Chennai Metropolitan Area

Contents Of
The Master
Plan
For this purpose all lands in the Metropolitan area have
been categorisedunder the following use zone.
01. Primary residential use zone
02. Mixed residential use zone
03. Commercial use zone
04. Light industrial use zone
05. General industrial use zone
06. Special and hazardous industrial use zone.
07. Institutional use zone
08. Open space and recreational use zone
09. Agricultural use zone
10. Non-urban use zone

Ordinary
Residential
Buildings and
other small
developments
Ordinary residential / predominantly residential buildings,
Clinics, dispensaries, nursing homes with floor area not
exceeding 300 sq.m. and G+1 floor in height.
Working women hostels / old age homes with floor area
not exceeding 500 sq.m. and G+1 floor in height.
Corporate / Institution Guesthouses with floor area not
exceeding 300 sq.m. and G+1 floor in height.
Cottage industries (with number of workers not exceeding
8 and electric machineries not exceeding 5 H.P.) with floor
area not exceeding 300 sq.m. and G+1 floor in height.
Nursery schools, primary schools with floor area not
exceeding 300 sq.m.
Reading rooms, libraries, Post office, EB Office, telegraphic
office, Local body maintenance offices with floor area not
exceeding 300 sq.m.

Ordinary
Residential
Buildings and
other small
developments

Ordinary
Commercial
Buildings and
other small
developments
Ordinary commercial / predominantly commercial
buildings including shops, private offices, banks,
restaurants, fuel filling stations with or without service
stations not exceeding 5 H.P, Departmental stores, clinical
labs, Schools of Commerce, with floor area less than 300
sq.m. and up to Ground +one floor.

Ordinary
Commercial
Buildings and
other small
developments

Cottage
industries,
Green industries
and Orange
industries

Institutional
buildings
Including nursery schools, Primary schools and religious
buildings with floor area exceeding 300 sq.m. Secondary
schools, Colleges, Higher Educational, Technical &
Research Institutions, Students hostels & Dormitories,
Research Institutions,
Broadcasting, Telecasting & Telecommunication centers,
Government & Quasi Government offices, and Institutions,
Government archives, Museums, Art galleries and Public
libraries, foreign missions, Consulates and embassies.

Institutional
buildings

Religious buildings
with floor area less
than 300 sqmand
height not exceeding
G+1 floors

Transport Terminals
such as Bus
Terminals, Bus stands,
Railway stations,
Truck terminals,
container terminals:

DCR for
Tiruchirappalli

Floor Space
Index
In cases of hospital buildings an additional Floor Space
Index of 0.25 is allowable over and above the normally
permissible FSI.
The Floor space index for Information Technology
development shall be allowed at 1.5 times of the FSI
ordinarily permissible for respective use of that zone
provided site extent is not less than 2000 sq.m. This
benefit will not be available for primary residential use
zone.
Maximum Floor Space Index allowable is 1.5 times of the
Floor Spaces Index ordinarily permissible.

Parking and
Parking
facilities
For the use of the occupants and of persons visiting the
premises for the purposes of profession, trade, business,
recreation or any other activity parking spaces and parking
facilities shall be provided within the site to the satisfaction
of the Authority and conforming to the standards specified
in Schedule- II.

Plot
In cases where the extent of the site where residential or
predominantly residential developments proposed
exceeds 10000 square metres (1 hectare), the developer
shall reserve minimum ten per cent of the site area
(excluding roads if any handed over to local body) and
provide housing thereon for lower income groups with
dwelling units not exceeding 45 square metres in floor area
each, either within the site proposed for group
development or in a location within a radius of 5 k.m . from
the site under reference. The developer or promoter or
owner shall sell these small dwellings only for this purpose.
No conversion or amalgamation shall be permissible in
these cases of lower income group dwellings.

Fire Safety
Fire safety, detection and extinguishing systems.-
(a) All building in their design and construction shall be such as
to contribute to and ensure individually and collectively and
the safety of life from fire, smoke, fumes and also panic arising
from these or similar other causes.
(b) In building of such size, arrangement or occupancy that a
fire may not itself provide adequate warning to occupants,
automatic fire detecting and alarming facilities shall be
provided where necessary to warn occupants or the existence
of fires, so that they may escape, or to facilitate the orderly
conduct of fire exit drills.
(c) Fire protecting and extinguishing system shall conform to
accepted standards and shall be installed in accordance with
good practice as recommended in the National Building Code
of India, (amended from time to time) and to the satisfaction
of the Director of Fire and Rescue Services by obtaining a no
objection certificate from him.

Lift
Every multi-storeyed development erected shall be
provided with,-
(i) lifts as prescribed in National Building Code;
(ii) a stand-by electric generator of adequate capacity for
running lift and water pump, and a room to accommodate
the generator;
(iii) an electrical room of not less than 6 metres by 4.0
metres in area with a minimum head room of 2.75 metres
to accommodate electric transformer in the ground floor;
and the space for installation of transformers shall
conform to the regulation given in Schedule- VIII
Among the lifts provided within the premises atleastone
lift shall have the facility to accommodate the wheel chair
size 80cm x 150cm.

Structure
The design and plans of the building shall be made and
signed by a qualified Civil or Structural Engineer and an
Architect who should possess the qualification referred to
in the Architects Act, 1972 (Central Act 20 of 1972), so as
to become a member of the profession of Architects
under the provisions of the said Act. The qualified Engineer
or Structural Engineer should also be Class I licensed
Surveyor registered with Corporation / Local body
concerned.

CASE STUDY -I
HyneticCommercial, Bangalore

Hynetic
Commercial,
Banashankari,
Bangalore

•According to DCR 15- 18m height
building setback of 6m should be
given
•Here,
•Building height -16.5m
• East - 4.5m
• South -3m
• North - 1.5m
• West –1.5m
•FSI should be 2.5 for an 18-24m width
road
•Here it is 3.25

•According to DCR min 1.5m should be
the width of the stairway in
commercial complex
Here,
1.2m

•According to DCR min 2.5m
should be the height of the
fire exit corridor
•Here,
•3.25m

CASE STUDY -II
Rockwell International School,
Hyderabad

Rockwell
International
School,
Kokapet,
Hyderabad
CLIENT: SUBASH BODA
TYPE: EDUCATIONAL INSTITUTION
SITE AREA: 9140 SQM.
GROUND FLOOR AREA: 2745 SQM.
FIRST FLOOR AREA: 2400 SQM.
SECOND FLOOR AREA: 2400 SQM.
FAR: 0.8 (DECENT AND SATISFACTORY AS PER
REGULATIONS)

SL.NO. ASPECT PRESENT NEEDED REMARKS
01 ROAD WIDTH 9 M 9 M GOOD
02 HEIGHT PERMIS. 12 M 18 MAX GOOD
03 RAILWAY LINE DIST. - 30 M MIN. -
04 ELECTRIC POLES DIST 3M (HTL), 3M (HTL), GOOD
2M (LTL) 1.5M (LTL) NOT SATISFIED
05 SET BACKS (FOR 2500 SQM- PLOT
SIZE)
(STILT + 2 CELLARS ALLOWED) -THE
SITE HAS ONE STILT FLOOR FOR
KITCHEN AND STORAGE)
*FOR 18MTS HT.UPTO 9M ROAD
WIDTH IN GENERAL STANDARDS
FRONT- 3M 3M GOOD
SIDE- 5M,(OS- 4M) 7M NOT SATISFIED
06 PARKING 14 FW NOT SATISFIED

INFERENCES
Though The Setbacks Have Been Compromised Upon, It
Might Not Cause Any Huge Problems For The Time Being
As The Site Is Almost In A Vacant Residential Area With
Inhabited Land Around.
Parking Is Not Sufficient For Four Wheelers And Is Visible
Since The Vehicles Are Parked In The Side Street Lane.
Too Much Of Height Relaxation And Regulation.
Electric Poles At A More Prescribed Distance And Is
Actually Good -Aesthetics Wise And Functionality Wise.

Thank You!