About This Presentation

Practical design of steel anchor bolts and base plate


Slide Content

DESIGN OF COLUMN BASE PLATES AND STEEL ANCHORAGE TO CONCRETE Khaled Eid

Outline Introduction Base plates Material Design using AISC Steel Design Guide Concentric axial load Axial load plus moment Axial load plus shear Anchor Rods Types and Materials Design using ACI Appendix D Tension Shear

Introduction Base plates and anchor rods are often the last structural steel items to be designed but the first items required on the jobsite Therefore the design of column base plate and connections are part of the critical path

Introduction Anchors to appear in concrete drawings with location of each anchor in x and y direction Pedestal should be designed to suit the supporting column and anchors Usually allow for enough edge distance of 6d bolt Usually use to nuts to avoid slip

Introduction Vast majority of column base plate connections are designed for axial compression with little or no uplift Column base plate connections can also transmit uplift forces and shear forces through: Anchor rods Bearing end plate Shear lugs under the base plate or embedding the column base to transfer the shear force. Column base plate connections can also be used to resist wind and seismic loads Development of force couple between bearing on concrete and tension in some or all of the anchor rods

Introduction Anchor rods are needed for all base plates to prevent column from overturning during construction and in some cases to resist uplift or large moments Anchor rods are designed for pullout and breakout strength using ACI 318 Appendix D Critical to provide well-defined, adequate load path when tension and shear loading will be transferred through anchor rods In seismic zones the pedestal should carry 2.5 the factored design load

Introduction Grout is needed to adjust the level Grout to transfer the load from steel plate to foundation Grout should have design compressive strength at least twice the strength of foundation concrete When base plates become larger than 600mm, it is recommended that one or two grout holes be provided to allow the grout to flow easier

Base plate Materials Base plates should be ASTM A36 material unless other grade is available Most base plates are designed as to match the pedestal shape A thicker base plate is more economical than a thinner base plate with additional stiffeners or other reinforcements

Base Plate Design

Design of Axially Loaded Base Plates Required plate area is based on uniform allowable bearing stress. For axially loaded base plates, the bearing stress under the base plate is uniform A 2 = dimensions of concrete supporting foundation A 1 = dimensions of base plate Most economical plate occurs when ratio of concrete to plate area is equal to or greater than 4 (Case 1) When the plate dimensions are known it is not possible to calculate bearing pressure directly and therefore different procedure is used (Case 2)

Case 1: A 2 > 4A 1 Determine factored load P u Calculate required plate area A 1 based on maximum concrete bearing stress f p =1.7f` c (when A 2 =4A 1 ) Plate dimensions B & N should be determined so m & n are approximately equal

Case 1: A 2 > 4A 1 Calculate required base plate thickness where l is maximum of m and n Determine pedestal area, A 2

Case 2: Pedestal dimensions known Determine factored load P u The area of the plate should be equal to larger of: Same as Case 1 Same as Case 1

Design of Base Plates with Moments Equivalent eccentricity, e, is calculated equal to moment M divided by axial force P Moment and axial force replaced by equivalent axial force at a distance e from center of column Small eccentricities  equivalent axial force resisted by bearing only Large eccentricities necessary to use an anchor bolt to resist equivalent axial force

Design of Base Plate with Small Eccentricities If e<N/6 compressive bearing stress exist everywhere If e is between N/6 and N/2 bearing occurs only over a portion of the plate

Design of Base Plate with Small Eccentricities Calculate factored load ( Pu ) and moment (Mu) Determine maximum bearing pressure, fp Pick a trial base plate size, B and N Determine equivalent eccentricity, e, and maximum bearing stress from load, f 1 . If f 1 < fp go to next step, if not pick different base plate size Determine plate thickness, t p M plu is moment for 1 in wide strip

Design of Base Plate with Shear Four principal ways of transferring shear from column base plate into concrete Friction between base plate and the grout or concrete surface The friction coefficient ( m ) is 0.55 for steel on grout and 0.7 for steel on concrete Embedding column in foundation Use of shear lugs Shear in the anchor rods (revisited later in lecture)

Design of Shear Lugs Determine the portion of shear which will be resisted by shear lug, V lgu Determine required bearing area of shear lug Determine shear lug width, W, and height, H Determine factored cantilevered end moment, M lgu Determine shear lug thickness

Anchor Rods Two categories Cast-in place: set before the concrete is placed Drilled-in anchors: set after the concrete is hardened

Anchor Rod Materials Preferred specification is ASTM F1554 Grade 36, 55, 105 ksi ASTM F1554 allows anchor rods to be supplied straight (threaded with nut for anchorage) , bent or headed Wherever possible use ¾-in diameter ASTM F1554 Grade 36 When more strength required, increase rod diameter to 2 in before switching to higher grade Minimum embedment is 12 times diameter of bolt

Cast-in Place Anchor Rods When rods with threads and nut are used, a more positive anchorage is formed Failure mechanism is the pull out of a cone of concrete radiating outward from the head of the bolt or nut Use of plate washer does not add any increased resistance to pull out Hooked bars have a very limited pullout strength compared with that of headed rods or threaded rods with a nut of anchorage

Anchor Rod Placement Most common field problem is placement of anchor rods Important to provide as large as hole as possible to accommodate setting tolerances Fewer problems if the structural steel detailer issued anchor bolt layout for placing the anchors form his 3d model

Anchor Rod Layout Should use a symmetrical pattern in both directions wherever possible Should provide ample clearance distance for the washer from the column Edge distance plays important role for concrete breakout strength Should be coordinated with reinforcing steel to ensure there are no interferences, more critical in concrete piers and walls

Design of Anchor Rods for Tension When base plates are subject to uplift force T u , embedment of anchor rods must be checked for tension Steel strength of anchor in tension Ase =effective cross sectional area of anchor, AISC Steel Manual Table 7-18 fut= tensile strength of anchor, not greater than 1.9fy or 125 ksi Concrete breakout strength of single anchor in tension h ef =embedment k=24 for cast-in place anchors, 17 for post-installed anchors  2 ,  3 = modification factors

Design of Anchor Rods for Tension A No =Projected area of the failure surface of a single anchor remote from edges A N =Approximated as the base of the rectilinear geometrical figure that results from projecting the failure surface outward 1.5h ef from the centerlines of the anchor Example of calculation of A N with edge distance (c 1 ) less than 1.5h ef

Design of Anchor Rods for Tension Pullout strength of anchor Nominal strength in tension N n = min(N s , N cb , N pn ) Compare uplift from column, T u , to N n If T u less than  N n ok If T u greater than  N n must provide tension reinforcing around anchor rods or increase embedment of anchor rods

Design of Anchor Rods for Shear When base plates are subject to shear force, V u , and friction between base plate and concrete is inadequate to resist shear, anchor rods may take shear Steel Strength of single anchor in shear Concrete breakout strength of single anchor in shear  6 ,  7 = modification factors d o = rod diameter, in l = load bearing length of anchor for shear not to exceed 8d o , in

Design of Anchor Rods for Shear A vo =Projected area of the failure surface of a single anchor remote from edges in the direction perpendicular to the shear force A v =Approximated as the base of a truncated half pyramid projected on the side face of the member Example of calculation of A v with edge distance (c 2 ) less than 1.5c 1

Design of Anchor Rods for Shear Pryout strength of anchor Nominal strength in shear V n = min(V s , V cb , V cp ) Compare shear from column, V u , to V n If V u less than V n ok If V u greater than  V n must provide shear reinforcing around anchor rods or use shear lugs

Combined Tension and Shear According to ACI 318 Appendix D, anchor rods must be checked for interaction of tensile and shear forces

References American Concrete Institute (ACI) 318-02 AISC Steel Design Guide, Column Base Plates, by John T. DeWolf, 1990 AISC Steel Design Guide (2 nd Edition) Base Plate and Anchor Rod Design AISC Engineering Journal Anchorage of Steel Building Components to Concrete, by M. Lee Marsh and Edwin G. Burdette, First Quarter 1985

Common mistakes

Careful when considering the location of anchors to concrete walls

Bolts miss alignment or clash with gusset plate