Learn more
about our products:
eagleburgmann.com/api682
1
4 5
2
3
6
Seal chamber details
A Flush connection plugged
Example seal: EagleBurgmannLY9TC
single stationary metal bellows mechanical seal.
1 Flush (F), plugged (for possible future circulating
fluid or for venting on vertical pumps)
2 Vent (V), if required
3 Heating/cooling inlet (HI or CI), heating/cooling
outlet (HO or CO), if required
4 Quench (Q)
5 Drain (D)
6 Seal chamber
Plan 02
Process side Plan02
A
Applicable EagleBurgmann seals
Category 1
Configuration 1CW-FX:
APItex-S
Configuration 2CW-CW:
APItex-T
Configuration 2NC-CS:
H75LG4-C
Configuration 3CW-FB:
APItex-T
Configuration 3NC-BB:
CGSH-KD
Category 2/3
Configuration 1CW-FL:H75VA4-S, LL9UC, LEK777, SH, LY9SA,
MBS682, LY9TC
Configuration 2CW-CW:
H75A4-T, LL9DTUU, LL9DJUU, LY9DTSS,
MBS682-PTA, LY9DZTT
Configuration 2CW-CS:
H75A4-C, LL9DTUE, LL9DJUE
Configuration 2NC-CS:
H75LG4-C
Configuration 3CW-FB:
H75A4-T, LL9DTUU, LL9DJUU, LY9DTSS,
MBS682-PTA, LY9DZTT
Configuration 3CW-BB:
H75A4-B, LL9DKUU, LY9DZSS, MBS682P-D
Configuration 3CW-FF:
LL9DSUU, SH-D, LY9DSTT
Category 2/3
Configuration 3NC-FB:
HRGS-DD, LNF992
Configuration 3NC-BB:
CGSH-KD
Configuration 3NC-FF:
RGS-D