Electrical Activity of the Heart

15,219 views 53 slides Jun 18, 2018
Slide 1
Slide 1 of 53
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53

About This Presentation

Electrical Activity of the Heart


Slide Content

Electrical Activity of the Heart By SATHISHKUMAR G ([email protected])

Outline Overview of the cardiovascular system. Review of nerve action potentials. Action potential propagation through the heart. ECG

Learning Objectives Describe the course of a cardiac impulse through the heart. Understand how the Na + , K + , and Ca 2+ channels function in sinoatrial and ventricular action potentials. Know the times a cardiac impulse appears in each part of the heat. Know the relationship of atrial and ventricular contraction to the ECG waves.

Cardiovascular System Keep in mind the full system when studying details. What does the heart need to do? What signal initiates contraction? Must be an automatic signal. Rhythmical excitation of the heart. The normal electrocardiogram

Flow of Electrical Signals in the Heart First, atria contract to fill ventricles. Then, ventricles contract to send blood to the lungs and peripheral circulation. S-A node generates the signal. Signal travels through internodal pathways and atrial muscle (atria contract). A-V node and bundle delay the signal and send it to the ventricles. Purkinje fibres rapidly carry the signal throughout the ventricles, where it then spreads, causing contraction.

Propagation of Electrical Signals in Heart Muscle Heart muscle is syncytial

Cardiac Muscle Branching cells One or two nuclei per cell Striated Involuntary Medium speed contractions

Cardiac Muscle Found only in heart where it forms a thick layer called the myocardium Striated fibers that branch Each cell usually has one centrally-located nucleus Fibers joined by intercalated disks IDs are composites of desmosomes and gap junctions Allow excitation in one fiber to spread quickly to adjoining fibers Under control of the ANS (involuntary) and endocrine system (hormones) Some cells are autorhythmic Fibers spontaneously contract (aka Pacemaker cells)

Cardiac Muscle Tissue

Properties of Cardiac Muscle Fibers

Excitation-Contraction Coupling and Relaxation of Cardiac Muscle

Excitation-Contraction Coupling

How are cardiac contractions started? Cardiac conduction system Specialized muscle cells “pace” the rest of the heart; cells contain less actin and myosin, are thin and pale microscopically Sinoatrial (SA) node; pace of about 65 bpm Internodal pathways connect SA node to atrioventricular (AV) node AV node could act as a secondary pacemaker; autorhythmic at about 55 bpm Bundle of His Left and right bundle branches Purkinje fibers; also autorhythmic at about 45 bpm ALL CONDUCTION FIBERS CONNECTED TO MUSCLE FIBERS THROUGH GAP JUNCTIONS IN THE INTERCALATED DISCS

Action Potentials ( APs ) APs are the electrical signals that we have been discussing. Review nerve AP on next slide. Should know the following: - Membrane potential - Nernst equation - Na + , K + , and Ca 2+ channels - Na + /K + ATPase New material will be APs in the SA node and ventricles.

Nerve Action Potential Note: membrane potentials are measured inside-outside. This will be important to Remember when we discuss ECGs .

Sinoatrial Node Pacemaker of the heart. Flattened ellipsoid strip of cells on the right atrium. No contractile filaments. Electrically connected to atrium.

Sinoatrial Node Action Potential Phase 4: slow depolarization due to Na + and Ca 2+ leak until threshold. Note fast Na + channels are inactive at -60 to -40 mV. Phase 0: at threshold, Ca 2+ channels open. Phase 3: As in nerves, K + channels open during repolarization . Finally, note the slow rise and fall of the SA AP compared to that of the nerve AP, and the rhythmic firing.

AV Node and Bundle Delays AP from reaching the ventricles, allowing the atria to empty blood into ventricles before the ventricles contract.

Purkinje Fibres Receives the AP from the AV bundle and rapidly transmits the impulse through the ventricles.

Impulses in Ventricles At the termination of the Purkinje fibres , the impulse rapidly travels through the ventricle muscle fibres via gap junctions, from the inside ( endocardium ) to the outside ( epicardium ). The rapid propagation of the cardiac impulse through the Purkinje fibres and ventricles is important for an effective contraction.

Ventricular AP Phase 4: resting membrane potential near the K + equilibrium potential. Phase 0: depolarizing impulse activates fast Na + channels and inactivates K + channels. Phase 1: Transient opening of K + channels and Na + channels begin to close. Phase 2: Ca 2+ channels are open, key difference between nerve AP. Phase 3: repolarization , Ca 2+ inactivate and K + channels open. Refractory period: Na + channels are inactive until membrane is repolarized .

The refractory period is short in skeletal muscle, but very long in cardiac muscle. This means that skeletal muscle can undergo summation and tetanus, via repeated stimulation Cardiac muscle CANNOT sum action potentials or contractions and can’t be tetanized

Cardiac Muscle

Properties of Cardiac Muscle fibers

Electrical Events Autorhythmicity of Cells – important to understand, some cardiac drugs work at this level.

1 2 3 4

Sequence of Excitation

Modifying the Basic Rhythm: Extrinsic Inervation of the Heart

Autonomic nervous system modulates the frequency of depolarization of pacemaker Sympathetic stimulation (neurotransmitter = ); binds to b 1 receptors on the SA nodal membranes Parasympathetic stimulation (neurotransmitter = ); binds to muscarinic receptors on nodal membranes; increases conductivity of K+ and decreases conductivity of Ca2+ How do these neurotransmitters get these results?

Electrocardiography (EKG) Examines how Depolarization occurs in the Heart

If a wavefront of depolarization travels towards the electrode attached to the + input terminal of the ECG amplifier and away from the electrode attached to the - terminal, a positive deflection will result.  If the waveform travels away from the + terminal lead towards the - terminal, a negative going deflection will be seen.  If the waveform is travelling in a direction perpendicular to the line joining the sites where the two leads are placed, no deflection or a biphasic deflection will be produced. ECG examines how depolarization events occur in the heart

The electrical activity of the heart originates in the sino-atrial node.  The impulse then rapidly spreads through the right atrium to the atrioventricular node.  (It also spreads through the atrial muscle directly from the right atrium to the left atrium.)  This generates the P-wave The first area of the ventricular muscle to be activated is the interventricular septum, which activates from left to right.  This generates the Q-wave Next the bulk of the muscle of both ventricles gets activated, with the endocardial surface being activated before the epicardial surface.   This generates the R-wave A few small areas of the ventricles are activated at a rather late stage.  This generates the S-wave Finally, the ventricular muscle repolarizes. This generates the T-wave

Since the direction of atrial depolarization is almost exactly parallel to the axis of lead II (which is from RA to LL), a positive deflection (P wave) would result in that lead. Since the ventricular muscle is much thicker in the left than in the right ventricle, the summated depolarization of the two ventricles is downwards and toward the left leg:   this produces again a positive deflection (R-wave) in lead II, since the depolarization vector is in the same direction as the lead II axis. Septal depolarization moves from left to right, the depolarization vector is directed towards the - electrode of lead II (RA), and therefore a negative deflection (Q-wave) is produced.

Electrocardiography

THANK YOU