FIRE SAFETY karnaal.pptx fire fighting basic

mahlasanjay 203 views 59 slides Jul 28, 2024
Slide 1
Slide 1 of 59
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53
Slide 54
54
Slide 55
55
Slide 56
56
Slide 57
57
Slide 58
58
Slide 59
59

About This Presentation

Complete fire Safety training demonstration


Slide Content

WEL COME

Basic Fire Safety & Emergency Evacuation 2

1 What is Fire.? 2 Types of Fire 7 Emergency Evacuation 3 Fire Fighting Equipment 5 Fire Prevention & Fire Protection 4 Fire Fighting Method 6 Fire Alarm System 8 General Requirements 3

01. What is Fire.? Fire is a chemical reaction of three components: Oxygen Fuel Heat 4

o Fire Triangle or Combustion Triangle is a sample model for und e r s t a nd i n g t h e n ecessa r y ingredients for fire. Fire Triangle HSE KARNAL 5

Fire Tetrahedron Fire tetrahedron can be describe as pyramid which is solid having four faces: Oxygen Fuel Heat C he m i c a l R ea c t i o n HSE KARNAL 6

The Spread of Fire Direct contact - in their early stage, fires spread most entirely b y c on t a c t o f f l a m e t o combustible object. C ondu c t io n – t r an s f e rr e d o f heat through solid materials. HSE KARNAL 7

The Spread of Fire Convection – transferred of hea t b y a i r m o v e m en t , ho t a i r rises due to reduced density Radiation – heat transferred from one surface to another across the space HSE KARNAL 8

4 S T A G ES OF FIRE I n ci p i e n t Or Ignition Growth Fu 3 lly De v el o p ed Decay HSE KARNAL 9

Cooking E q u i p m e n t 's Smoking E l ec t r i ca l D i s t r i b ut i o n Equipment's Electrical A p p li a n c es Oil, Kerosene. Petrol & Lubricants Gas L eaka g e s Heating E qu i pm e n t 's P o w er S t o r a g es E x p l o s i v e s Common Causes of Fire HSE KARNAL 10

END CHAPTTER 01 HSE KARNAL 11

02 . C l ass ifi ca t i o n o f F i r e CLASS - A : Combustible solid like Wood, Paper, Plastic, etc. C L A SS - B : F l a mm ab l e L i qu i d s & G r ea s e s li k e L P G , D i e s e l , e t c . CLASS - C : Involving Electrical fire. C L A SS - D : M e t a l F i r e s li k e a l u mi n i u m , e t c . CLASS - K : Involving kitchen fire. HSE KARNAL 12

END CHAPTTER 02 HSE KARNAL 13

Fire Fighting Equipment 1 Fire Beater 2 Fire Bucket 7 Fire Hydrant 3 Fire Blanket 5 Fire Ball 4 Fire Extinguisher 6 Fire Hose Reel 8 Fire Sprinkler HSE KARNAL 14

Fire Fighting Equipment 01. Fire Beater 02. Fire Bucket A simple tool for fighting wildfires, consisting of a piece of rubber at the end of a pole. A Fire Bucket is filled with sand or water and is used to extinguish fires. HSE KARNAL 15

Fire Fighting Equipment 03. Fire Blanket 04. Fire Ball A sheet of flexible material, typically woven fiberglass , used to smother a fire in an emergency. A round-shaped fire extinguisher that self-activates after about three to five seconds of fire exposure. HSE KARNAL 16

Fire Fighting Equipment 05. Fire Hose 06. Fire Hydrant Fire hose reel is a flexible pipe that is rolled and has a direct connection to the water. Fire hydrants are used to extinguish and control the spread of fire. HSE KARNAL 17

Fire Fighting Equipment 07. Sprinklers 06. Extinguisher Fire sprinkler system is an automatic extinguishing system that prevent fire growth. Fire extinguisher is a portable or movable apparatus used to put out a small. HSE KARNAL 18

Fire Fighting Equipment Types of Extinguisher & Color Code & Uses Water W. C Fo a m C O 2 DCP CLASS- A,B CLASS- A,B,C CLASS- A,K CLASS- A C L A S X S - B,C C L A X S S - C CLASS- B,C C L A S X S - A ,D HSE KARNAL 19

Fire Fighting Equipment P Fire Extinguisher Operating Procedure A S S Pull the safety pin Aim the target S qu ee z e the trigger Sweep side by side HSE KARNAL 20

Fire Fighting Equipment Fire Extinguisher Using TIPs Check for your own safety before starting to extinguish a fire. Assess the fire only a small fire should be fought using a fire extinguisher Select the right type of fire extinguisher. Remember the simple acronym P.A.S.S. : Pull, Aim, Squeeze, Sweep, Always try to work in pair for safety. Target the base of the fire not the flame. If fire extinguished at first sight, stay ready for re-ignition. Keep minimum 8-10 feet distance from fire during use fire extinguisher. HSE KARNAL 21

Fire Fighting Equipment Fire Hydrant Color Code & Class CLASS - AA 1500 GPM CLASS - A 1000-1499 GPM CLASS - B 500-999 GPM CLASS - C 500 GPM HSE KARNAL 22

Fire Fighting Equipment Fire Sprinkler Types & Color Code Open Fire Sprinkler: Sprinkler that is not equipped with actuator or heat response element. Closed Fire Sprinkler: Sprinkler that is equipped with actuator or heat response element. HSE KARNAL 23

Fire Fighting Equipment Fire Sprinkler Types & Color Code 57 C/ 135 F 68 C / 155 F 79 C / 175 F 93 C / 200 F 141 C / 286 F 182 C / 360 F NOTE: Quick Response - 3MM bulb, Standard Response - 5MM bulb HSE KARNAL 24

Fire Fighting Equipment Types of Hose Delivery Hose Suction Hose Hose Reel Hose Percolating Hose Hard Suction Non-Percolate Partially Embedded Soft Suction Fully Embedded HSE KARNAL 25

Fire Fighting Equipment Type of Hose Percolating: Dimension- 38,50,63,70 mm Le n g t h - 15 , 22.5 , 3 m e t e r . Non-Percolating: Dimension- 38,50,63,70 mm L e n g t h - 15 , 22.5 , 3 m e t e r . Hose Reel Hose: Dimension- 19 mm Length- 30 to 60 meter. Soft Suction: Dimension- 102, 127 mm Length- 8 to 15 meter. Partially Embedded: D i m e n s i o n - 75 , 100 , 14 m m Le n g t h - 2. 5 t o 3 m e t e r . Fully Embedded: D i m e n s i o n - 75 , 100 , 14 m m Le n g t h - 2. 5 t o 3 m e t e r . HSE KARNAL 26

END CHAPTTER 03 HSE KARNAL 27

Fire Extinguishing Method S t a r v a ti on 01 Smothering 02 C oo li n g 03 HSE KARNAL 28

Fire Extinguishing Method Starvation Starvation is the process of depriving the f i re f r o m f ue l . i . e . c o m bu s t i b l e m a t e r ial s . Or Remove fuel from fire. HSE KARNAL 29

Fire Extinguishing Method Smothering Smothering is the process of depriving the fire of oxygen needed to sustain the fire. Or Remove Oxygen from fire. HSE KARNAL 30

Fire Extinguishing Method Cooling Cooling is the process of depriving the fire of Heat e.g. by applying a substance such as water that will absorb heat from the fire. Or Remove heat from fire. HSE KARNAL 31

END CHAPTTER 04 HSE KARNAL 32

Fire Prevention & Fire Protection Fire Prevention: It is a proactive steps taken to reduce fire hazards so that a fire does not have a chance to ignite. Fire Protection: It is a reactive approach which minimize potential damage or loss. 33

Fire Prevention & Fire Protection Fire Prevention Fire safety plan (approved) Risk assessment (update every 6 month) Workplace Inspections (daily, weekly, monthly, quarterly) Fire safety trainings (induction, annually) Regular fire drills Preventive maintenance (as per requirements) Housekeeping Management M a t e r ia l M anage m en t ( 5 -S T e c hnique ) HSE KARNAL 34

Fire Prevention & Fire Protection 02. Fire Protection Active Fire Protection: Active fire protection system is detect and extinguish a f i r e . T h i s c a n b e e i t he r m anua l o r au t o m a t i c . Passive Fire Protection: Passive fire protection system will help to prevent fire from spreading or resist the initial ignition. 35

Fire Prevention & Fire Protection Smoke and heat alarm Manual Call Point Fire Sprinklers Fire extinguishers Fire hydrants Video monitoring Etc. Compartment Fire proofing Fire door Fire wall Fire Stopper Fire Curtain / Baffle Etc. Active Fire Protection Passive Fire Protection 36

END CHAPTTER 05 HSE KARNAL 37

F i re A l arm S y st em Fire Alarm Control Panel: A fire panel is a safety appliance that r e ce i v e s i n f o r m a t i o n f rom d e v i ce s d e s i gn e d t o d e t ec t a n d r e po rt f i r e s , m on i t o r t h e i r op e r a t i on a l i n t e g r i t y . HSE KARNAL 38

F i re A l arm S y st em Types of Fire Alarm System Conventional fire Panel: Every device on the same circuit would report the same. Addressable fire Panel: It indicate the exact location of fire or smoke. 39

F i re A l arm S y st em Fire Detectors Fire Detectors: A device which can detect a fire, and provide a signal to an alarm circuit. Fire detectors are different types; Smoke Detectors Heat Detectors Flame Detectors 40

F i re A l arm S y st em 1.Smoke Detector Types of Fire Detectors Ionization SD Photoelectric SD Light Scattering Light Obstruction 41

2. Heat Detector Fixed Temp HD Rate Of Rise HD F i re A l arm S y st em Types of Fire Detectors HSE KARNAL 42

3. Flame Detector IR Detector UV Detector F i re A l arm S y st em Types of Fire Detectors 43

F i re A l arm S y st em Manual Call Point It is a device used to initiate an alarm signal . They operate by means of a simple button press or when glass is broken revealing a button. They can form part of a manual alarm system or an automatic alarm system. MCP activation is typically achieved through the use of a pull station or call point which then sounds the evacuation alarm for the relevant building or zone. 44

F i re A l arm S y st em Types of MCP Manual Call Point Push Type MCP Glass Break MCP Pull Type MCP 45

END CHAPTTER 06 HSE KARNAL 46

Fire Evacuation Procedure Action on Hearing Alarm Don’t panic and be calm. Stop any activity immediately and prepare to leave the room. Turn off all ignition sources such as AC, Equipment. Evacuate the room to nearest safe assembly area. Remain in the assembly area (in group) until instructed to leave. After the all clear alarm you may continue your work. 47

Fire Evacuation Procedure Assembly Area Checklist All the employee assemble at their designated assembly area. Assembly area far enough away from flying glass and other objects Head count of Employees is done and reported to ERT head. Injured are informed to the ERT Team. Access to emergency vehicles are not hindered Remain in the group until further notice. Do not re enter in building without permission. 48

Fire Evacuation Procedure Emergency Reporting Call 911 and say this is an emergency. Describe the incident location. Describe the nature of incident. Report injuries if any. Give you name, badge number and contact. Repeat the above information. Stay on the line until further instructed. HSE KARNAL 49

R esc u e – r e sc u e w h o i s i n i mmed i a t e d a nge r . Alert – Activate fire alarm (or) Dial emergency phone number. Contain/Confine – Close all doors and windows when evacuate, Extinguish/ Evacuate – Extinguish if small fires, if not then evacuate. R A C E RACE Method Fire Evacuation Procedure 50

Fire Evacuation Procedure Duties of ERT All Fire Equipment's are always in working condition. Any deviation needs to be reported to Facilities/Security Team. ERT should know the locations of Fire Extinguishers and their handling techniques ERT is to help Security/Fire Team in case of any Fire incident. ERT needs to ensure that emergency situations are handled peacefully and authoritatively without any stampede. ERT should know the details of Handicap person(s) and their workstation and contact details. W h i l e e v a c u at i o n o f e m p l o y e e s , p r i o r i t y t o b e g i v e n t o d i s ab l e d e m p l o y e e s , pregnant ladies and visitors. 51

Fire Evacuation Procedure Duties of ERT ERT assess the situation at the scene itself. If situation is not risky and can be controlled without any human safety risk then control same. In case situation warrants to evacuate the building, start evacuation with assistance of team members and simultaneously inform ERT Leader/Office Head for assistance or guidance. Follow the instructions of ERT Leader/Office Head and handle it appropriately. 52

D o n ’ t ru n – i t w ill make the fire G e t d o w n o n t o t he floor R oll o v e r - t his wil l pu t t he fl a m es worse! out 1 2 3 If your clothes are on fire: Fire Evacuation Procedure 53

END CHAPTTER 07 HSE KARNAL 54

Fire Safety General Requirements Storage of flammable and combustible materials shall be minimum Incompatible materials (flammable and oxidizer) shall not be stored together Vegetation (weeds &grass)shall kept down Minimum clearance of 0.6m or 2ft shall be maintained between the ceiling and the top level of any stocked material below Minimum 0.5m or 1.5ft clearance between top level of stocked material and sprinkler head Temporary wiring shall be installed according to the provision of NFPA 70. Electrical equipment should be regularly checked 55

GFCI (Ground Fault Circuit Interrupters) shall be provided where required. Smoking is permitted only in designated “Smoking Area” Open fires or open burning of materials are strictly prohibited. Proper bonding & grounding techniques shall be used for any operation. Trained and certified Fire Watch should be present all the at hot work area. Monthly inspection of all FACP and Fire Fighting equipment. CO2 fire extinguisher is prohibited to use in Confined Space. Fire Safety General Requirements 56

END CHAPTTER 08 57

Q UI Z ..? 58