Industrial rotating Machine Guarding.pptx

kamleshswarnkar17 14 views 10 slides Mar 03, 2025
Slide 1
Slide 1 of 10
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10

About This Presentation

Plant machine guarding


Slide Content

FUMER MACHINE GUARDING & CONVEYOR SAFETY AUDIT Date :- 08-07-2021 Lead Auditor Name : Mr. Ranadip Roy (HZL) Team Members: Mr. Aman Yadav ( HZL) Mr. Arjun DM (HZL) Mr. Basant Patra ( CBRE) Mr. Satyanarayan Sharma(ABPL)

Good practice DCS Operator Mr. Rajkumar instructed the Field Operator to check throughout the length of conveyor whether any person in standing near the conveyor before starting the conveyor

Inadequate machine guarding of Gear Box of all ID Fans Inadequate machine guarding of rotating shaft of conveyor

Though guard is present at head pulley the surrounding guard No. 13 height to be increased as per standard at RKD Conveyor Bidirectional conveyor No. 19 guard height to be increased as per standard at RKD Conveyor . It was observed that hand of a normal person is easily reachable to belt of conveyor

Guard at Motor No. 485 was missing at FFP Guarding at conveyor in RKD area needs to be done as per standard specification as there is risk of exposure to rotating parts

Inadequate Guarding at conveyor in RKD area needs to be done as per standard specification as there is risk of exposure to rotating parts below Inadequate Guarding at all motors in STG area needs to be done as per standard specification

Pump guarding to be ensured at STG Inadequate guarding of submersible pumps at STG Condensor

Motor guarding to be ensured at CPL area Colour Coding of Bucket elevator proxy guarding to be ensured

Equipment No. M205 rotating shaft machine guarding is inadequate at TGP Guarding has allowable access to rotating parts

Adequate guarding with proper mesh to restrict body parts to be provided in motors at TGP Rusted guarding to be replaced with proper mesh to restrict body parts in motor at TGP