Master Baseband 6620 & 6630 Commissioning On Site

wafawafa52 950 views 45 slides Jun 17, 2024
Slide 1
Slide 1 of 45
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45

About This Presentation

Master Base band 6620 & 6630 Commissioning On Site


Slide Content

Baseband 6620 & 6630 Commissioning On-Site

Power Cycle Button Power cycle your device (Turn off and on) Much like any computer, many issues are resolved by simply turning your phone off, waiting a minute or two, then turn it back on. It's good practice to do this once or twice a week. A factory Reset Button   erases your data from the Base Band. While data stored in your Drive-C. Account can be restored, all files, software and their data will be uninstalled.  

Baseband script Baseband Configuration Files 1. RBS Summary Script .xml 2. Site Basic Script .xml 3. Site Equipment Script .xml 4. Transport Network Script 5. Radio Network Scrip Note: Only Files 1, 2 & 3 are loaded to the BB6620/30. Each file must carry .xml. Which means, when manually commissioning the BB, it looks for all files with .xml.

1. RBS Summary Script The purpose of the RBS Summary File is to define the paths to other configuration files used for integration of a node. Summary script is the file which is used when BB commissioning is started.

2. SITE equipment script > The purpose of the Site Equipment File is to handle configuration of equipment. › The most important part is to set up the first Baseband and the TN Port on the Baseband Unit, to enable Site Basic File to run. › Important part of site equipment script : – Equipment such as cabinet data, alarm, antenna, riport, rilink, etc. – >EquipmentSupportFunction such as PSU, PDU – Node Support as radio sector definition

3. Site Basic SCRIPT The purpose of the Site Basic File is to set the attributes defining security management, system management, and transport network configuration. Important part of Site Basic Script – Security Management – Transport definition, VLAN, IP, Router, Transmission Port – License Management.

Step#1:Folder Preparation › Create a folder the following will be stored: – Baseband SW package (17.Q3) – Msftpserver or FreeFTPd (recommended) – configuration scripts (RBSSummary, Site Basic, Site Equipment)

Step#2: Communication setup 1. Power Up Baseband 6630/6620. 2. Connect Laptop to port LMT on Baseband using RJ45 cable 3. IP Laptop Setting Base Band IP 169.254.2.2 PC/Laptop IP 169.254.2.1 Ping 169.254.2.2

Note : These Files, with .xml are the files/scripts written and given by the RNC-Integrator. The most follow Netconf(.xml). This will enable the base band to be loaded and ready for integrations by the RNC-Specialist.

Note: 65% means, site Installation Complete and integration @5%, which means the site is ready to be turn on AIR by the Integrator/RNC Specialist. This equals the total of 70% complete BB.

Step#3: Board Restore (FORMAT) > Check Node status in Emergency Access link. >https://169.254.2.2/ea.html › Board Restore Button is used to format or erase previous Data or script install on the Baseband .

Step#4: SFTP >Server Firewall and antivirus should be disabled in the local PC. › Setting SFTP Server (Recommendation FreeFTPd) – - IpAddress : 169.254.2.1 – - User : ftp – - Password : ftp

SFTP Server Setting SFTP Server (Continue..) – Port 22 – SFTP root directory is the folder where Package and scripts are saved.

APP#1. SFTP (1)

APP#1. SFTP (2)

APP#1. SFTP (3)

Manual Commissioning

Manual Commissioning

Manual Commissioning
Tags