By S.RAMKUMAR PRAGYA CONSULTANCY Email: [email protected] Measurement System Analysis (MSA)

Purpose The purpose of Measurement System Analysis is to qualify a measurement system for use by quantifying its accuracy, precision, and stability.

A measurement system can be characterized, or described, in five ways: Location (Average Measurement Value vs. Actual Value): Stability Bias Linearity Variation (Spread of Measurement Values - Precision): Repeatibility Reproducibility

Location (Average Measurement Value vs. Actual Value): Stability  refers to the capacity of a measurement system to produce the same values over time when measuring the same sample. As with statistical process control charts, stability means the absence of "Special Cause Variation", leaving only "Common Cause Variation" (random variation). Bias , also referred to as Accuracy, is a measure of the distance between the average value of the measurements and the "True" or "Actual" value of the sample or part. Linearity  is a measure of the consistency of Bias over the range of the measurement device. For example, if a bathroom scale is under by 1.0 pound when measuring a 150 pound person, but is off by 5.0 pounds when measuring a 200 pound person, the scale Bias is non-linear in the sense that the degree of Bias changes over the range of use.

Variation (Spread of Measurement Values - Precision): Repeatability  assesses whether the same appraiser can measure the same part/sample multiple times with the same measurement device and get the same value. Reproducibility  assesses whether different appraisers can measure the same part/sample with the same measurement device and get the same value.

The diagram below illustrates the difference between the terms "Accuracy" and "Precision": Efforts to improve measurement system quality are aimed at improving both accuracy and precision. Figure 1:  

Requirements Statistical stability over time. Variability small compared to the process variability. Variability small compared to the specification limits (tolerance). The resolution, or discrimination of the measurement device must be small relative to the smaller of either the specification tolerance or the process spread (variation). As a rule of thumb, the measurement system should have resolution of at least 1/10th the smaller of either the specification tolerance or the process spread. If the resolution is not fine enough, process variability will not be recognized by the measurement system, thus blunting its effectiveness.

Measurement Systems Analysis Fundamentals Determine the number of appraisers, number of sample parts, and the number of repeat readings. Larger numbers of parts and repeat readings give results with a higher confidence level, but the numbers should be balanced against the time, cost, and disruption involved. Use appraisers who normally perform the measurement and who are familiar with the equipment and procedures. Make sure there is a set, documented measurement procedure that is followed by all appraisers. Select the sample parts to represent the entire process spread.  This is a critical point. If the process spread is not fully represented, the degree of measurement error may be overstated.

Measurement Systems Analysis Fundamentals If applicable, mark the exact measurement location on each part to minimize the impact of within-part variation (e.g. out-of-round). Ensure that the measurement device has adequate discrimination/resolution, as discussed in the  Requirements  section. Parts should be numbered, and the measurements should be taken in random order so that the appraisers do not know the number assigned to each part or any previous measurement value for that part. A third party should record the measurements, the appraiser, the trial number, and the number for each part on a table.

Stability Assessment Select a part from the middle of the process spread and determine its reference value relative to a traceable standard. If a traceable standard is not available, measure the part ten times in a controlled environment and average the values to determine the  Reference Value.  This part/sample will be designated as the  Master Sample . Over at least twenty periods (days/weeks), measure the master sample 3 to 5 times. Keep the number of repeats fixed. Take readings throughout the period to capture the natural environmental variation. Plot the data on an x̄ & R chart - consult the Statistical Process Control section of the Toolbox and calculate control limits. Evaluate the control chart for statistical control. Again, consult the Statistical Process Control section of the Toolbox for assistance with this assessment.

Bias Assessment Referring to the & R chart, subtract the Reference Value from to yield the Bias: Bias = x̄ - Reference Value  Process Variation = 6 Standard Deviations (Sigma)  Calculate the Bias percentage:  Bias Percentage = Bias / Process Variation

Bias Assessment Analyze the results. If there is a relatively high value, examine the following potential root causes: Appraisers not following the measurement procedure An error in measuring the Reference Value Instability in the measurement. If the SPC chart shows a trend, the measurement device could be wearing or calibration could be drifting.

Repeatability and Reproducibility Assessment (Gage R&R): Follow the steps below to conduct a Gage R&R study: Determine the number of appraisers, trials, and parts, which may vary from study to study. A rule of thumb is 2-3 appraisers, 2-3 trials, and 5-10 parts - with 10 being greatly preferred. The downloadable MoreSteam.com spreadsheet will accommodate any combination within this range. In this example we will use 2 appraisers, 3 trials, and 10 parts. Identify three appraisers who are all trained in the proper measurement procedure and identify them as A, B & C. Fill in the yellow blanks at the top of the form with the required background information (Gage Type, Date, etc.). Also fill in the blank at the bottom of the form asking for the total specification tolerance.

Repeatability and Reproducibility Assessment (Gage R&R): Collect ten parts that represents the range of process variation. If the parts don't vary as much as the process, the gage error will be overstated. Identify each part with a number 1-10 in such a way that the appraisers can not see the numbers as they take the measurements. Please refer to the data collection chart below. You will see that appraiser A's three trials are recorded in rows A-1, A-2, and A-3. Likewise, Appraiser B has rows B-1, B-2, and B-3, and Appraiser C has rows C-1, C-2, and C-3. Start with Appraiser A and measure each of the ten parts in random order. A third party should record the results of the first trial in row A-1. Proceed to Appraisers B & C following the same process. Then repeat the process for trials two and three.

Thumb rule The rule of thumb for acceptance of a measurement system is a total Gage R&R of 30% or less of the lessor of Total Variation or the Specification Tolerance. In this case, the measurement system is capable, and can be used as a basis of decision making. If the measurement system has error in excess of 30%, the first step to improve results is to analyze the breakdown of the error source. If the largest contributor to error is Repeatability, then the equipment must be improved. Likewise, if Reproducibility is the largest source of error, appraiser training and adherence to procedures can yield improvement.

Summary Measurement Systems Analysis is a key step to any process improvement effort. By understanding existing measurement systems a team can better understand the data provided by those systems and make better business decisions.