About This Presentation

An Optical Fiber
Optical Fiber used in Indian Railways
Methods of Jointing a Fiber Optic Cable
Mechanical Splicing
Fusion Splicing
Measurement And Testing Of Signals in an OFC
Indian Railway Telephone Exchange
Digital Multiplexing Hierarchies
PDH
SDH


Slide Content

OPTICAL COMMUNICATION SYSTEM IN INDIAN RAILWAYS

CONTENTS About the Organisation An Optical Fiber Optical Fiber used in Indian Railways Methods of Jointing a Fiber Optic Cable Mechanical Splicing Fusion Splicing Measurement And Testing Of Signals in an OFC Indian Railway Telephone Exchange Digital Multiplexing Hierarchies PDH SDH

ABOUT THE ORGANIZATION RailTel Corporation of India Limited (RailTel) is a Government Department that comes under the Ministry of Railways. The Corporation was formed in Sept 2000 with the objectives to create nationwide Broadband Telecom and Multimedia Network in all parts of the country, to modernize Train Control Operation and Safety System of Indian Railways. RailTel has created state of the art multimedia telecom network using SDH/DWDM based transmission systems. It generates much needed revenues for implementing Railways’ development projects, safety enhancement and asset replacement programmes

OPTICAL FIBER An Optical Fiber is a long, thin strand made with pure glass about the diameter of a human hair . OFC consists of Core, Cladding, Buffers and Jacket as shown in figure.

Specifications Of Optical Fiber Cable Used In Indian Railways In Indian Railways, 24 Fibre armoured Optical Fiber Cable.   General Requirement Of Cable The cable shall consist of 24 monomode fibres and shall be suitable for direct underground burial as well as mechanized laying in the duct .   Service Condition Optical Fibre cable shall be able to withstand the following environmental conditions. Ambient temperature 0 to + 550 C Storage temperature -200 C to + 700 C Overall Diameter   The overall diameter of the cable shall not be more than 20 mm and uniform throughout the length from top to end .   Fibre & Unit Identification   Fibres are coloured with readily distinguishable durable colours . The 6 loose tubes have the following colours :1-Blue,2-Orange,3-Green,4-Brown,5-Slate,6-White.

Specifications Of Optical Fiber Cable Used In Indian Railways Technical Requirements

Methods for jointing of fibre optic cable There are two methods for jointing Optical fibre cable 1. SPLICING 2. USING CONNECTORS The splicing is further divided into two methods 1. Mechanical Splicing 2. Fusion Splicing Splicing is the process of connecting two bare fibres directly without any connectors . Splicing provide much lower insertion loss compared to fiber connectors that’s why Splicing is preferred over the use of Connectors. Fiber mechanical splicing – Insertion loss < 0.5dB Fiber optic cable fusion splicing – Insertion loss < 0.1dB

MECHANICAL SPLICING Mechanical splices are used to create permanent joints between two fibres by holding the fibres in an alignment fixture and reducing loss and reflectance It uses a transparent gel or optical adhesive between the fibres that matches the optical properties of the glass. Mechanical splices generally have higher loss and greater reflectance than fusion splices, and Because the fibres are crimped to hold them in place, do not have as good fiber retention or pull-out strength

FUSION SPLICING Fusion splicing  is the process of fusing or welding two fibres together usually by an electric arc.  Fusion splicing  is the most widely used method of  splicing   I t provides for the lowest loss and least reflectance It also provides the strongest and most reliable joint between two fibres.

FUSION SPLICER Splicing Machine Inserting a Fiber in the Splicer after cutting Alignment Check by the Machine After the approval of the Alignment the fusion starts

MEASUREMENTS AND SYSTEM TESTING Measurement of the Optical Signal can be done using (i) Power Meter (ii) OTDR

Measurement using POWER METER STEP 1- Connect the meters together using the patch cord as shown in Figure 7.4. Switch them on. Select the required wavelength and, on the power meter, switch to dBr mode . Wait until the readings are stabilized. At this stage, the power meter will indicate the incoming power level in dBm. Set the power meter to dBr and it will accept the incoming light level as the reference level. STEP 2- Connecting them to the system ( see Figure 7.5 ) Disconnect the fiber to be tested at the transmitter and plug in the light source. Connect the power meter to the far end . The power meter will immediately show a new figure such as – 8.2 dBr. This is the loss over the system.

OPTICAL TIME DOMAIN REFLECTOMETER OTDR uses a system similar to radar set, It sends out a light pulse and act on the reflected light from the fiber. The OTDR can continuously measure the returned power level and hence figure out the losses on the fiber link. A typical OTDR trace

MEASUREMENT OF LENGTH USING OTDR WE can find the length of the fiber, If we know the speed of the light and can measure the time taken for the light to travel along the fiber

TELEPHONE EXCHANGE Telephone Exchange is a place where switching between two subscribers is done through either manually or electronically. In addition to switching, signalling and controlling are also done at “Exchange ” A telephone exchange is a telecommunications system used in the public switched telephone network or in large enterprises . Basics of Telephone Exchange Main Distribution Frame Card Frame Mother Board Power Supply Panel & Protective Devices

COMPONENTS OF AN EXCHANGE Main Distribution Frame (MDF) It is the place where both external and internal cables are terminated. The cross connection between the two cables conductors is done on the MDF and this is done by means of jumper wires It carries all the protective devices used in the exchange. They are Fuses, Heat coils & Lightning protectors The MDF is the most suitable place for testing purposes Card Frame: It contains different slots in which the nominated cards are to be inserted. It is different in different types of exchanges. Mother board: It is basically a connectivity between different cards. It is a PCB with 1,2,3 layers. Power supply panel: It provides power supply to different cards in the exchange at different low D.C. voltages. It also includes protective devices like fuses etc.

Main functional areas in Telephone Exchange (a) Switching Function: It provides a temporary path for simultaneous, bi-directional speech between: i ) Two subscribers connected to the same exchange. This is called as “Local switching”. ii) Two subscribers connected to different exchanges. This is known as “Trunk switching”. ( b) Signalling function: The signalling function enables the various equipment in a network to communicate with each other in order to establish and supervise the calls. It is of two types: i ) Subscriber line signalling : It enables a call to be set up, supervised and cleared within same exchange ii ) Inter exchange signalling : It enables a call to be set up, supervised and cleared between exchanges. Card Frame in RAILTEL Main Distribution Frame in RAILTEL

DIGITAL MULTIPLEXING HIERARCHIES

PLESIOCHRONOUS DIGITAL HIERERCHY Greek word ‘Plesio’ means Close so PDH the different stages of mux are almost synchronous but not completely synchronous the PDH is a technology for transporting voice or data between multiple devices and which are working with clock sources with accepted tolerance levels for synchronisation PDH was built for Digital Transmission of Signals over Twisted Pair, Co-axial cable and Microwave PCM is the technique used in PDH network which is based on the TDM PDH had different standards in different countries using different data rates at same levels

PDH Hierarchy adopted in India

LIMITATIONS OF PDH Bit interleaving multiplexing Lack of Flexibility Lack of consensus on standards Limited Network Management/debugging Defined for selected topologies Mode of Transmission Less bandwidth compared to SDH

SYNCHRONOUS DIGITAL HIERARCHY at each hierarchical level, synchronous transport module is formed with information pay-load and overhead bits and a synchronizing mechanism is in-built to ensure all n etwork elements work to a master clock reference All the limitations of PDH are removed in SDH SDH Multiplexers used in RAILTEL

Building Blocks of SDH At each point there is a network element(NE) NE moves signals between optical fibres Each NE has 2 types of connectors – High speed connectors called LINES & low speed connectors called Tributaries The building Block of SDH includes: Regenerator Terminal Multiplexer Add/Drop Multiplexer Digital Cross Connect

Building Blocks of SDH Regenerates the Clock & Amplitude of incoming distorted & attenuated signal Combines lower order SDH & PDH signals to higher order STM(synchronous Transport module) It extracts & inserts information into high speed SDH It helps in increasing the aggregation as we can connect any to any terminal

MAPPING OF 2Mbps into STM-N VC-12

MAPPING OF 2Mbps into STM-N

MAPPING OF 2Mbps into STM-N

ADVANTAGES OF SDH SDH permits the mixing of the existing European and North American PDH bit rates All SDH equipment is based on the use of a single master reference clock source & hence SDH is synchronous Compatible with the majority of existing PDH bit rates SDH provides for extraction/insertion, of a lower order bit rate from a h igher order aggregate stream, without the need to de-multiplex in stages. SDH provides for a standard optical interface thus allowing the inter-working of different manufacturer’s equipment