About This Presentation

Powerpod Compact lithium ion inverters


Slide Content

USER MANUAL
WARRANTY CARD
SAFETY INSTRUCTIONS
INSTALLATION GUIDE
MODEL
WM- 1000 -128900 
CAPACITY
1KVA
DC INPUT
12V
Model Description
Specifcation
Block Diagram
Front Panel Details 
Installation procedure 
Warranty Details 
1.
2.
3.
4.
5.
6.
2
3
4
5
6-9
10
SI.NO Title  Page no. 
INDEX
1. MODEL DESCRIPTION
2
POWERP D
Enduring Energy
www.powerpodenergy.com
POWERP D
Enduring Energy
1800 203 3316
www.powerpodenergy.com

INPUT
OUTPUT
BATTERY DETAILS
OUPUT POWER 
DIMENSION 
UPS MODE
INVERTER MODE
FREQUENCY 
180V-255V
110V-280V 
50±3% Hz 
220 V      rms ± 5% 
50±1% Hz
Pure Sine Wave 
2. SPECIFICATION
VOLTAGE 
FREQUENCY 
WAVE FORM 
(RESISTIVE LOAD) 
625x320x180 mm 
WEIGHT 
PROTECTIONS 
Salient Features of Inverter :
28 KG
Over Load, Short Circuit, 
AC over Voltage, AC under Voltage, 
Battery Deep discharge, 
Battery Over Charge, Over Temperature 
800 W
TYPE 
CAPACITY/POWER  
VOLTAGE
CHARGING CURRENT  
LiFePO  
90 AH/1.15 KWh  
12.8V
15 A (CCCV)   
3
• LED Indications for better user      
  interface.
• Over Charge Protection.
• Automatic Overload, Battery Low, Over   
  Temperature & Short Circuit protection    
  sense.
• High Efciency.
• Easy to Service.
• No Humming Noise.
• Maintenance Free.
• Pollution Free.
• Wall mountable.
• MCB base Dual Protection for EV Power  
   and Battery.
• Easy to Installed.
• Longer Life.
• No emission.
• 10 + years life span of Battery.
• Multistage Software Protection.
• Light Weight, Space saver Design.
FIG.1.1 BLOCK DIAGRAM OF INVERTER
3. BLOCK DIAGRAME
AC I/P
VOLTAGE
NTC
NTC
+
+
-
-
-
P-
B0 B1 B2 B3 B4
AC O/P
VOLTAGE
B-
AC MCB
16A
1 KVA
INVERTER 
POWER BOARD
INVERTER 
TRANSFORMER 
DALY BMS
100A/12V
DC MCB 
63A DUAL POLE 
BATTERY 
90AH/12V
4
Front Panel
Control
Graphic Description Indication Meaning
MAINS ON
BACK-UP ON
BATTERY LOW
CHARGING/ CHARGED
OVERLOAD/ SHORT CIRCUIT
ON/ OFF – ON
ON/ OFF - OFF
NORMAL CHARGING
Continuous Glow Mains Present
Continuous Glow
Continuous glow 
with beep sound
Battery Voltage Low
Continuous glow Battery Charging
Blinking
Blinking with beep sound
Battery Charged
Overload Alarm
Blinking without beep sound Shutdown
Continuous glow with beep sound
ON/ OFF Switch LED Glow
ON/ OFF Switch LED Not Glow
Normal Charging Switch 
LED Not Glow
Short Circuit
Inverter ON
Inverter OFF
Normal Charging Mode
Continuous glow 
without beep sound
Battery Voltage Low 
Cut
Back-up ON
Thermal Circuit 
Breaker trip
Display showing Temperature 
High with beep sound
www.powerpodenergy.com
POWERP D
Enduring Energy
www.powerpodenergy.com
POWERP D
Enduring Energy

4. FRONT PANEL DETAILS
MAINS
AC CHGR
SOL CHGR
BACKUP
BAT LOW
OVER LOAD
-         RED LED On while Mains input present
-         YELLOW LED On while battery charging
-         GREEN SOL CHGR – Not using (future option)
-         GREEN LED On while Load on Inverter
           LED Blink while Load on Mains
-         YELLOW LED On while Battery Low
-         RED LED On while Output Over Load
MAINS
AC CHGR
SOL CHGR
BACK UP
BAT LOW
OVER LOAD
NORMAL MODE
UPS MODE
AC CHARGER
INV Mode switch Press 5 Sec to change between UPS mode (Narrow) 
& Inverter Mode
High voltage cut Of = 285V/Low cut of =110v
NV Mode switch Press 5 Sec to change between UPS mode (Narrow) 
& Inverter Mode High voltage cut of = 255 V/Low cut of = 180 V
Press 5 Sec to turn ON/OFF battery charging
5
AC O/P
INV
UPS ON
AC CHGR
AC I/P
OUTPUT
SOCKET
INVERETER
ON SWITCH 
UPS 
MODE/INVERTER 
MODE SWITCH 
AC CHARGER
ON /OFF 
SWITCH 
AC INPUT
Fig 1.2 Inverter Switch ,Connectors & MCB
5. INVERTER INSTALLATION PROCEDURE
Determine the ideal Place for installation
Accurate and safe Mounting of the Inverter
Connecting the inverter to the mains
Turn on the mains MCB
Check the display and monitor the values
Turn of the mains MCB
Turn on the battery MCB
Output connected to the load
Switch ON the inverter
Turn on the mains and check the charging current
6
MAINS MCB
BATT MCB
www.powerpodenergy.comwww.powerpodenergy.com
POWERP D
Enduring Energy
POWERP D
Enduring Energy

PRODUCT OVERVIEW
CLAMP
The inverters are designed for indoor  installation , to increase the safety, 
performance and lifespan of the inverter, please select the mounting location 
carefully based on the following rules:
The inverter should be installed on a solid surface, far from fammable or corrosion 
materials, where is suitable for inverter’s weight and dimensions.   The ambient 
temperature should be within 5°c ~ 55°c
The installation of inverter should be protected under shelter.
Do not expose the inverter to direct sunlight, water, rain, snow, spray lightning, etc.
Vertical installations need to ensure clearance of fans for proper cooling. Never 
mount the inverter upside down due to lack of heat dissipation.
Ventilation: Allow at least 1 Feet of clearance around the system for air fow.
INSTALLATION OF INVERTER MOUNTING
7
Fig.: Installation Environment
Fig.: Installation Position
The Installation of Inverter should be protected under shelter. 
Do not expose the inverter to direct sunlight, water rain, snow, spray lighting etc.
The inverter should be installed vertically on the wall or lean back on plane 
with a limited tilted angle. Please refer to bellow picture
8
www.powerpodenergy.comwww.powerpodenergy.com
POWERP D
Enduring Energy
POWERP D
Enduring Energy

Don’t
Do
Mount the Inveter on the noninfammable such aas metal.etc
There is a fear of fre.
Don’t put the infammable meterial near  to the inverter
Install the inverter at the eurable place against weight
Ther is the fear of  injury by dropping
Don’t installed and operate damaged inverter, or inverter of which 
parts are ommitted There is fear of injury by dropping
PRECAUTION
9
Only trained and qualifed professionals can perform the installation 
or maintenance.
Prevent total battery discharge at all times.
Familiarise yourself with the pre-alarm feature and act when the 
pre-alarm is activeto prevent a system shutdown.
If the pre-alarm is active or if the BMS has disabled the loads, make 
sure that thebatteries are recharged immediately. Minimise the time 
the batteries are in a deepdischarged state.
The batteries must spend at least 2 hours in absorption charge mode 
each month toensure sufcient time in balancing mode.
Please use insulated protective tools for inspection; otherwise, 
electric shock accidentor personal injury may be cause
10
WARRENTY CARD DETAILS
TERMS OF WARRANTY
This warranty is not valid in case of the following events:
The warranty period of Inverter 2 years and Battery pack 5 years.
This warranty directly related to overall warranty of product against 
manufacturing defects.
The product is not used according to the instruction given in the user’s 
manual.
The warranty not applicable for accidents, mishandling, improper installation, 
fre, food, natural calamities and no fault of the company in case of the 
product is handed over to any third party.
The warranty will not apply if the original seals are found broken or tempered 
with.
Installation in indoor locations that does not provided the conditioned 
environment of 5° to 55°C.
Out of warranty period
MODEL NO
SERIAL NO.
DATE OF PURCHASE
NAME &ADDRESS OF
PURCHASER
TELEPHONE NUMBER
NAME OF DEALER
WITH SEAL