Presentation on ModuLaser AirSense.pptx

ShashishAshu2 76 views 38 slides Aug 12, 2024
Slide 1
Slide 1 of 38
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38

About This Presentation

Airsense


Slide Content

V1.4

THIS DOCUMENT AND ITS CONTENT IS STRICTLY CONFIDENTIAL and may not be copied, disclosed or otherwise disseminated either in whole or in part without Carrier’s prior written approval. This document does not constitute an offer to supply any products or services or a binding contract thereto, nor does it give rise to legally enforceable rights or obligations. Carrier will not be bound to make any supply of products or services unless and until Carrier and your company enter into a formal written binding contract for the same. This document is intended solely to facilitate discussion between the parties. This document only sets forth certain information disclosed for the purpose of this meeting and a description of the financial and other terms that are anticipated to be included in a proposed written agreement between the parties and shall not create a legally binding or enforceable agreement (except for the confidentiality obligation) or offer. You acknowledge that Carrier standard terms and conditions are also anticipated to be included in a proposed written agreement. All information is delivered on an “as is” basis and all representations and warranties, express or implied, are hereby disclaimed, including, without limitation, that the information is accurate or reliable for any purpose whatsoever. Disclaimer

  Intorductie Carrier  Expert in  ASD ASD system overview ASD key applications What’s new in V1.4 Top 3 benefits of ModuLaser Modules ModuLaser System Overview ModuLaser – Built With The User In Mind Key features of ModuLaser V1.4 Why ModuLaser V1.4? Materials available Appendix Benefits by user Designer Installer Operator Maintenance Engineer Agenda

Introduction

Over 90 years experience in developing fire protection systems Includes some of the world’s leading fire system brands, including: Kidde Edwards Aritech Introduction to Carrier Ziton Autronica CARRIER FIRE & SECURITY PRODUCTS & FIELD $5.0B 2020 Net sales 28% FIRE & SECURITY Carrier Total Sales

Carrier | Experts in ASD PAGE/ 6 30 year experience in designing ASD systems  Hundreds of thousands of installed devices Patented technology: ClassiFire algorithm​ Modular smoke detection system Complete ASD portfolio built with users in mind Accessory portfolio to cover full range of applications Highly experienced support

Aspirating smoke detection is a system whereby a sample of air is continuously drawn from the protected area through a network of sampling pipes and passed through a high sensitivity laser detection chamber.​ AirSense | ASD system overview PAGE/ 7 Air from the detection area is drawn along the pipe by an efficient aspirator Air passes over a sensitive air-flow measuring sensor In the detection chamber, a high sensitivity laser sensor is used to detect smoke particles ​

Large Volume Buildings where there may be challenges due to air stratification or the height of the space Atria Large Volume Buildings Power Generation Harsh Environments where dust and icing are prevalent Manufacturing facilities; recycling plants, Cold rooms Covert Detection where building aesthetics needs to be preserved Museums Churches Difficult To Access Areas for maintenance and repair Correctional Facilities Clean Rooms Attics Areas Where Smoke Is Difficult To Detect Buildings with high airflow - Datacentres AirSense | ASD key applications Atria Clean rooms Cold Environments Hard to access areas High Airflow Areas High Airflow Areas Large Volume Buildings PAGE/ 8 Harsh Environments Covert Detection Large Volume Buildings

Modulaser What’s New In V1.4 Firmware Upgrade

Using Reference Detector to compare relative sensitivity Higher reliability/reduced nuisance alarms, whilst maximising sensitivity Immediate notification of fault via IP connectivity Remote fault notification, reducing downtime Able to cover a large volume of a building, whilst being able quickly locate where a fire is starting with MatrixScan Faster response to smoke, reducing damage and risk to life Large area coverage with pinpoint fire location ModuLaser | What 1.4 Firmware upgrade brings you PAGE/ 10

Carrier Confidential and Proprietary SenseNET+ RS485 Reference detector - enabling the desensitization of detectors Approved at: 3rd party integration Support blow-back New features: PAGE/ 11 ModuLaser | bringing it all together v1.4 Filter Maintenance Updated Software LAN/WAN via Ethernet Graphics integration MatrixScan Backward compatibility Reference detection SenseNET RS485* Command module * Only supported on Command Display Module 

ModuLaser | What’s new in v1.4 Filter Maintenance Date Adjustable date for when filter replacement warning needs to be displayed IP / Ethernet Connectivity Enabled on all display modules Providing: Email notification of fires and/or faults Connect remotely with Remote software for maintenance SenseNET+ RS485 Reference detector - enabling the desensitization of detectors Connect to ModuLaser , wherever you are Plan your maintenance to optimize performance

3rd Party Integration Integration via Modbus to 3rd party building management systems Included as standard on ModuLaser Command Display module Graphics / ATS8600 Integration via Modbus to ATS8600 with the use of ModuLaser Command Display module Std. ATS8600 package include 2 x ModuLaser CM licenses ModuLaser | What’s new in v1.4 Integrating seamlessly with other systems for more efficient operation G raphics integration for full system monitoring

MatrixScan Pinpointing the location of the smoke based on the two detectors going into alarm : D3 & D9 in alarm => smoke at VD40 D12 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 VD20 VD21 VD22 VD23 VD24 VD25 VD26 VD27 VD28 VD29 VD30 VD31 VD32 VD33 VD34 VD35 VD36 VD37 VD38 VD39 VD40 VD41 VD42 VD43 VD44 VD45 VD46 VD47 VD48 VD49 VD50 VD51 Blow-Back Systems Ensure good operation in dirty environments, by keeping sampling pipe system clean and without blocked sampling holes ModuLaser | What’s new in v1.4 For applications where pinpointing a fire quickly and accurately is vital For dirty environments where   frequent cleaning of the sampling pipe systems is required

Alarm level Detector level B B B B A B Detector level A Reference Detector For environments where both high sensitivity and low nuisance alarms are key PipeCAD Update New PipeCad and Remote software designed to be user friendly -  designs quick and easy to do Updated graphics Individual pipe / detector selection Best blower speed selection Intelligent guidance on EN54 classes Covers EN and UL standards ModuLaser | What’s new in v1.4

Backwards Compatibility Modulaser V1.4 is fully compatible with previous versions , making system upgrades and system expansions easy ModuLaser | What’s new in v1.4

ModuLaser | Detector modules Standard Display module Command Display module Minimum Display module Detector module

AirSense | Full aspirating detector portfolio Micra 10* 1 pipe entry, limited holes Micra 25* 1 pipe entry Micra 100* 2 pipe entry HSSD2* 4 pipe entry ModuLaser * 1 to 8 pipe entries, with pipe location Full range of detectors – suitable for any application * Availability may vary subject to local approval

Modulaser Built With The User In Mind

Operation Design Maintenance Install ModuLaser | Built with the user in mind

Operation Laser Dust Discrimination Early Detection – 4 Alarm Levels High Reliability – Lower False Alarms Deals With Harsh Environments No Delays To locate Zone in Alarm MatrixScan to pinpoint location Reference Detector Function Email Notification of early alarms Design Intuitive and user friendly Software Maintenance Remote Fault Notification Remote Maintenance Maintenance Wizard Easy Module Replacement Only one zone disabled during maintenance Event log per module Detailed chart recording of detector values Install Top or Bottom Pipe Entry Quick Fix Pipe Adapters Intuitive Programming Easily Scalable Throughout Life Programming Wizard All Channels Together Or Distributed Configuration via display UI or laptop Backplane concept for 2-phased install ModuLaser | Built with the user in mind

ModuLaser | Built with designers in mind New Remote configuration SW PipeCAD Design Software New PipeCAD design SW Moved to .NET backbone Multiple detectors per floor One file per site Revamped graphics Real 3D view Multi-lingual support Improved drawing environment New Remote software Easy configuration via computer Remote diagnostics New ATS8600 Providing integration & monitoring Integrates, intrusion, video and access control, as well as other fire products ATS8600 Graphics UI and System integration*

ModuLaser | Built with installers in mind Quick and scalable installation Easy Install All channels at one location or distributed Quick fix pipe adapters Pipe entry from top or bottom with 180° rotatable detector module Docking station concept Independent channel operation (fan, laser, data log, event log & inputs/outputs)

ModuLaser | Built with installers in mind Intuitive installation Easy Configuration Installation Wizard Intuitive user interface with colour display + functional buttons Flexible input and output programming

ModuLaser | Built with operators in mind Easy Operation 24/7 connectivity Reduced nuisance alarms Patented technology to reduce nuisance alarms Reference detector support Large event storage 20 000 event-log per module Storage space - 1 month at 1 sec resolution No delays to localize zone in alarm MatrixScan (cluster or network) to quickly locate smoke detected Scalable throughout system life Patented modular and scalable concept – field configurable Day / Night mode operation Ensuring optimal sensitivity, at night during reducing building activity Easy and flexible day to day management

ModuLaser | Built with maintenance engineers in mind 24/7 Connectivity Receive email notifications of faults & events USB and IP for configuration and maintenance  Modbus over IP (Command display modules) Easy maintenance Easy replacement of display or detection module Maintenance Wizard Detailed event-logs  and chart recordings  Informed and Planned Maintenance Plan your maintenance to optimize performance Pre-schedule filter replacement dates Remotely connect before site visit, to establish any special maintenance actions or materials Know before your go

Key Features & Benefits

Multi-Channel High Sensitivity Smoke Detector Modular and scalable concept Global language support and approvals Fully backwards compatible with current range Flexible connectivity options Easy to use interface Standalone or networked solution Relay or APIC* connectivity to fire system * SenseNET RS485 SenseNET+ RS485 Relay outputs & Supervised inputs Addressable loop via APIC** Command Module Display LAN/WAN ModuLaser | V1.4 System Overview PAGE/ 28 * Only supported on Command Display Module       ** Availability may vary subjected to local approval ​

ModuLaser | Key features and benefits of v1.4 Early Detection + Fewer False Alarms ClassiFire detection algorithm 4 configurable alarm levels Ability To Deal With Harsh Environments Laser Dust Discrimination Waste-gate technology Programmable Sensitivity Levels 4 different alarm sensitivity levels can be programmed Allows early detection of fire, even at smouldering stage

Why Choose ModuLaser v1.4 ? Lower cost installation Quick fit pipe adaptors => reduced installation time Pipe entry top or bottom => reduced pipe length => installation time Lower cost maintenance Intuitive User Interface Remote diagnostics possible,  avoiding repeat site visits Lower cost programming/commissioning  Intuitive user interface Set up wizard Programmable inputs and outputs Less intensive training Intuitive user interface Programming and maintenance wizards

Materials Available Social Posts Brochures Materials can be found at ModuLaser - Fire Security Products

Appendix

ModuLaser – built with the designer in mind Intuitive & User Friendly Software New PipeCad and Remote software users need less training to use it Design a compliant system in less than 5 minutes

ModuLaser – built with the installer in mind Top or Bottom Pipe Entry Makes for easy installation, whatever the site configuration Quick Fix Pipe Adapters Making installation both easy and quick All Channels Together Or Distributed The flexibility of ModuLaser means that systems can be installed with all pipework being fed back to one place, or with detectors installed at different locations around the building, whichever provides that best operating and maintenance regime Programming Wizard To make programming easier and quicker, a programming wizard is available to set up the system once the hardware has been installed, ensuring that critical parameters are set Intuitive Programming Programming of the system has been specifically designed to be intuitive, again helping to ensure that set and commissioning are quick and easy . Easily Scalable Throughout Life Of System As with everything in life, things change. However, if a system needs to be expanded, or shrunk, to accommodate a changing operating environment, this can be easily done, as the system is fully scalable throughout its life, with changes in the field possible No Delays To locate Alarm Zone – Matrixscan Early Detection – 4 Alarm Levels Ability to set different alarm levels (per detector), from very sensitive to pick up very early traces of smoke to full alarm condition Enables checks to take place, even at smouldering stage, to prevent fire before it takes hold and avoid need for full evacuation Email Notification Of Early Alarms Selected personnel can be notified of possible fire before it takes hold and becomes a full alarm – saving assets and, potentially, lives

Remote Maintenance Some system diagnostics can be carried out remotely, identifying maintenance materials that need to be taken to site, saving the cost of repeat site visits Maintenance Wizard The ModuLaser maintenance wizard makes maintenance quick and easy, saving time and money Remote Fault Notification. If the system develops a fault, nominated engineers are immediately informed so that the system can be immediately fixed, keeping downtime to a minimum Easy Display Replacement In case of accident or a fault, detectors can be quickly replaced ModuLaser – built with maintenance in mind

ASD System Overview Connectivity RS232 RS485 network Not Supported USB Connectivity No IP Connectivity No CONNECTIVITY EN54-20 Class A Up to 2 EN54-20 Class B Up to 4 EN54-20 Class C Up to 10 UL 268 6 th ed. & FM Up to 10 UL 268 7 th ed. & FM N/A Pipe length Up to 50m / 164 ft.** Alarm Levels 4 Outputs 2 x Alarm + Fault Inputs Optional expansion Micra 10* 1 pipe entry, limited holes Connectivity RS232 RS485 network Yes USB Connectivity No IP Connectivity No CONNECTIVITY EN54-20 Class A Up to 10 EN54-20 Class B Up to 10 EN54-20 Class C Up to 10 UL 268 6 th ed. & FM Up to 10 UL 268 7 th ed. & FM TBD Pipe length Up to 50m / 164 ft.** Alarm Levels 4 Outputs 2 x Alarm + Fault Inputs Optional expansion Micra 25* 1 pipe entry Connectivity RS232 RS485 network Yes USB Connectivity No IP Connectivity No CONNECTIVITY EN54-20 Class A Up to 20 EN54-20 Class B Up to 20 EN54-20 Class C Up to 20 UL 268 6 th ed. & FM Up to 20 UL 268 7 th ed. & FM N/A Pipe length Up to 100m / 328 ft.* Alarm Levels 4 Outputs 2 x Alarm + Fault Inputs Optional expansion Micra 100* 2 pipe entry Connectivity RS232 RS485 network Yes USB Connectivity No IP Connectivity No CONNECTIVITY EN54-20 Class A Up to 20 EN54-20 Class B Up to 40 EN54-20 Class C Up to 100 UL 268 6 th ed. & FM Up to 100 UL 268 7 th ed. & FM N/A Pipe length Up to 200m / 356 ft.* Alarm Levels 4 Outputs 4 x Alarm + Fault Inputs 3 x programmable HSSD2* 4 pipe entry Connectivity USB RS485 network Yes USB Connectivity Yes IP Connectivity Yes CONNECTIVITY per detector EN54-20 Class A Up to 20 EN54-20 Class B Up to 40 EN54-20 Class C Up to 50 UL 268 6 th ed. & FM N/A UL 268 7 th ed. & FM Up to 50 Pipe length Up to 250m / 820 ft.* Alarm Levels 4 Outputs 3 x programmable per module Inputs 2 x programmable per module ModuLaser* 1 to 8 pipe entries, with pipe location * Availability may vary subjected to local approval

What’s New In V1.4 – Product Improvements Firmware TCP / IP ModBus Adjustable filter replacement date E-mail notifications MatrixScan CyberSecurity Fire2 setting resolution Reference detector Polish language Support Hardware NAND EOL Blow -back cleaning system integration ATS8600 Support for 2 x Command Dis . in standard package C4 driver available Pipe CAD Design Software Individual pipe / detector selection Best blower speed selection Intelligent guidance on EN54 classes Remote Configuration Software Add Ethernet connectivity CyberSecurity protections . Update to 1.4.0 protocol Includes configuration for new features

* Availability may vary subjected to local approval EU/US cable entries Din rail mounting * Interconnection clip Rear cable entries Side clip
Tags