Liquid dosage form Quality control tests for Presented by: Puttamreddy Kavyasri M.pharm(pharmaceutics) 2023-2024 Sree vidyanikethan college of pharmacy (MBU)
Liquid dosage forms: Mainly there are two types: Liquid dosage Monophasic Biphasic Eg: Syrup elixier Eg: Suspension emulsion
Quality control test for syrups
control test for syrups: 1.visual inspection 2.pH measurements 3.Physical stability 4.Sucrose concentration 5.Light transmittance
Visual inspection : #Take the syrup in a transparent bottle and observe carefully It should be : 1.good looking 2.elegance in appearance
2. pH measurements: 2 methods: 1.By using ph paper 2.pH meter After getting the values we can compare with the required values.
3. Physical stability: We have to check: Its appearance(no crystallization and microbial growth). Colour must be completely soluble with other ingredients. Order and taste(palatable). Solid material is completely miscible in liquid.
4. Sucrose concentration: It is very important control test There is no specific method for the determinate sucrose in syrup. We use # Hplc and uv-spectroscopy Note: high concentration: crystallization of syrup occur Low concentration: favor for microbial growth.
5 . Light transmittance meter: Light transmittance meter is a newer tool that is used to check syrup colour. # a syrup sample is checked for color by passing light through the sample.the percentage of light transmission is compared to light transmission rates for different grades. Note: 1. No fingerprints on the syrup test bottle. 2. Syrup sample has no bubbles or cloudiness. Those may diminish the light that is transmitted through the sample.
Quality control test For elixirs
Quality control test for elixirs: Determination of alcohol conc Viscosity measurements
Determination of alcohol conc: elixir usually contains 5 to 40% alcohol. The determination of alcohol unless specified in the individual monograph. Cloudy distillates may be clarified by agitation with talc,or with calcium carbonate and filtration. For liquids it is presumed to contain less than 30% of alcohol.
2.viscosity measurement: viscosity is measured by different viscometers. Note: Higher the viscosity =Higher the stability It is used for syrup also.
Quality control test for suspension
Tests: Appearance Photo microscopic examination c olour ,odour and taste pH value Pourability Viscosity Redispersibility Particle size
1. Appearance: It should be uniform and elegant. Particles should be well distributed. No hard cake formation of particles. The suspension is poured in a transpirant glass container and is should be checked if there is any coagulated material adhering to the inside wall of the container
2.photo microscopic examination: The particle size distribution and crystal habit of suspension should examined by using microscope. It is mainly used to differentiate between flocculated and deflocculated particles. Degree of flocular (beta)= Flocculated deflocculated
3. c olour ,odour and taste: It is mostly used for orally taken suspensions . Variation in colour indicates that it is poor in distribution. Variation in taste is due to particle size and crystal habit.
4.pH value: For suspension pH should check before and after mixing .pH should be monitored and recorded time to time to ensure optimum pH environment. There are two methods: 1. pH paper. 2.pH meter.
5. pourability : It is done to ensure the pourable nature of suspension to check it will not cause any problem during filing and during handling by the patient.
6. viscosity It is main . The stability of suspension dependant on the sedimentation rate of dispersed phase which is dependant on viscosity of dispersed medium. The calculated values are compared if any deviation is occur then correction would done immediately . It can be measured by: 1.cup and bob viscometer 2.cone and plate viscometer
Cup and bob viscometer cone and plate viscometer
7. Redispersibility: By shaking the glass container which contain the suspension it should be easily redispersible by a moderate amount of shaking.
8. Particle size: Particle size can be measured by : 1. Optical microscope method. 2. Sedimentation method. 3.conductivity method.
9. Sedimentation method: In this we have to find sedimentation volume:
Quality control test For emulsions:
Tests for emulsions: Appearance Viscosity Particle size and particle count Determination of phase separation Determination of electrolytic properties Stability agitation
1.visual inspection: In this the sample is carefully examined for physical appearance of product for patient adherence and compliance is critical so it should be: Good looking elegant in appearance
2. viscosity : Viscosity increases flocculation of globules will be reduced and also the brownian movement of globules will also be hindered leading to creaming So, optimum viscosity is needed for good stability. It is checked by: Cup and bob viscometer. Cone and plate viscometer . penetrometer
3. Particle size and particle count: As globule size is reduced they tend to exhibit brownian movement.so, it is necessary to choose the optimum globule size for maximum stability. We can perform by using optical microscopy, sedimentation by using andreasen apparatus and coulter counter apparatus.
4. Determination of phase separation : It may be done by: Visually Measuring the volume of separated phases
5. Determination of electrophoretic properties : Determination of electrophoretic properties like zeta potential is useful for assessing flocculation since electrical charges on particles influence the rate of flocculation. O\w emulsion having a fine particle size will exhibit low resistance but if particle size increase, then it indicates a sign of oil droplet aggregation and instability.
6.stability: The stress condition used for spreading up instability of emulsion includes: Centrifugal force,agitation force aging and temperature . 1. Centrifugation : In that centrifugation at 3750 rpm in a 10 cm radius centrifuge for a period of 5 hours is equivalent to the effect of gravity for about 1 year. 2. Agitation: 1. In this believed that no coalescence of droplet take place unless drouplets impinge upon each other 2.It is believed that no coalescence of droplet take place unless droplets impinge upon each other.