Radiation Protection Methods

Radiation protection Radiation protection, sometimes known as radiological protection, is defined by the International Atomic Energy Agency (IAEA) as "The protection of people from harmful effects of exposure to ionizing radiation, and the means for achieving this". The IAEA also states "The accepted understanding of the term radiation protection is restricted to protection of people

Why it is necessary ? Exposure above than threshold level produces following biological effects: Somatic effect Genetic effect Teratogenic effect Radiation may……. Deposit energy Damage DNA Create ionization in the body leading to free radicals formation leads to biological damage.

Susceptibility to radiation The LD 50/30 ( the dose that kill 50% population in 30 days) is influenced by the : Source of radiation Dose rate The LD 50/30 of x rays for humans is 250-450 Rad. Rad*… is a unit of absorbed dose for any ionizing radiation.

Radiosensitivity of living cells Low sensitivity : Mature RBCs , Ganglion cells, Muscle cells, Mature connective tissue Intermediate sensitivity: Gastric mucosa, mucus membrane, esophageal epithelium, urinary bladder epithelium. High sensitivity: Primitive blood cells , spermatogonia, Lymphocytes.

General Principles of Radiation Safety 1 ) Increase the distance between source and personnel. 2) Use of protective barriers. 3) Reduction of exposure factors and unnecessary radiography. 4) Use of radiation monitoring devices. 5) X-ray beam filtration and proper shielding of tube head. 6) Age and sex of involved personnel.

1) Increase in Distance between Source and Personnel. Distance is an important factor in reducing exposure. Doubling the distance from source will reduce the radiation exposure by four . Use tongs, forceps and trays to increase the distance between yourself and radiation source. Always know the radiation intensity, where you perform most of your work and if it is high then move to lower dose areas during work delays.

Continue……. No individual other than operator and essentially needed person should be there. Animal should not be restrained manually use either chemical or physical method of restraining. Operator should be on shielding booth or behind the screen or at least 6 feet away from source when exposure is made. No part of body should be exposed to primary beam.

2) Use of Protective Barriers These barriers are against scatter radiation not against primary beam. Barrier used are; a) Aprons: Should have a minimum of 0.25mm lead covering. Material used is lead rubber covered with cloth or plastic impregnated with metallic lead. Aprons should not be folded as protective material tend to separate, should keep flat.

Use of Protective Barriers b) Gloves and Goggles : The lead equivalent of gloves should not be less than 0.33mm. Gloves should be checked by radiography for cracks which can easily be missed on visual inspection. Lead goggles should be used during fluoroscopic examination c ) X ray room and equipment: Room should be away from public places E quipment should be checked for possible leakage .

Continue…… Room should also be well coated with lead along with free from any leakage . The wall of room should be at least 22cm thick and should be of concrete into which iron may be introduced. Warning signs must be placed near X ray room regarding potential hazards.

3) Reduction of Exposure factors and unnecessary Radiography Correct exposure factors must be used in first attempt. Repeated exposures definitely enhance exposure level. Many time owners demand radiography when it is not justified, unnecessary exposure should be avoided .

4) Use of Radiation Monitoring Devices Radiation monitoring devices like “film badges” should be worn all the time by individuals involved in radiographic work. Ideally one film badge should be at belt level to monitor whole body exposure while other at neckline to estimate exposure to skin of head neck and eyed . Radiation monitoring badges available in rings, clips and wrist badges.

5) X-ray beam Filtration and Shielding of tube head a) Filtration : Aluminum filters of at least 2.5mm thickness should be used to absorb the soft X rays to reduce the amount of scatter radiation. By this exposure dose can be reduced upto three to four times. b) X-ray tube head : It should be well shielded from all sides except the exit window.

6) Age and Sex of involved Personnel Persons under 18 years of age should not be involved in radiography because of the sensitivity of the growing tissues. Pregnant females should not be involved because of extreme sensitivity of embryos at certain stages of development.

Practice ALARA ALARA means “ As LOW As Reasonably Achievable”. Any type of ionizing radiation poses some risk. As exposure increases so does risk. Limit your exposure whenever possible.

References An Introduction to Radiation Protection in Medicine by Jamie V. Trapp, Tomas Kron An Introduction to Radiation Protection by Alan Martin, Sam Harbison. Introduction to Radiation Protection by J Sabol