Shaft couplings 2 split muff

840 views 10 slides Mar 26, 2020
Slide 1
Slide 1 of 10
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10

About This Presentation

JNTUK
DMM 1
Shaft couplings
split muff coupling

video link: https://youtu.be/dNyGr5ykL8Q


Slide Content

SHAFT COUPLINGS – Split muff D. Narendra Varma, Assistant Professor, Mechanical Engineering Dept., Miracle Educational society Group of Institutions.

Split Muff coupling Clamp or compression coupling. No.of bolts – multiples of 4 Advantages Easy to assemble & dismantle Easily removed without shifting the shaft Disadvantages Difficulty in dynamic balancing Unsuitable for shock loads Necessary to provide a guard

Design procedure for split muff coupling

Example It is required to design a split muff coupling to transmit 50 kW power at 120 rpm The shafts, key and clamping bolts are made of plain carbon steel 30C8 (S yt = 400 N/mm 2 ). The yield strength in compression is 150% of the tensile yield strength. The factor of safety for shafts, key and bolts is 5. The number of clamping bolts is 8. The Coefficient of friction between sleeve halves and the shaft is 0.3. ( i ) Calculate the diameter of the input and output shafts. (ii) Specify the length and outer diameter of the sleeve halves. (iii) Find out the diameter of clamping bolts assuming that the power is transmitted by friction. (iv) Specify bolt diameter using standard empirical relations. (v) Specify the size of key and check the dimensions for shear and compression criteria.

References: Machine Design - V.Bandari . Machine Design – R.S. Khurmi Design Data hand Book - S MD Jalaludin .