East,North,Front & West Block completed. Front & West Block is G+4 and rest is G+3. In all places, the corridor is towards one side except the East Block South side, where both side rooms and the corridor are on the Centre.
South Block 195'x66' East side 22’x 55' The existing open-air stage needs to be repositioned. Minimum distance from the boundary is 13'.
The central corridor is 10 feet wide To one side is 30 feet a wide room and the other side is 22 feet wide room. The South Block is proposed to be a G+2 building. The First floor is the Library and the second floor is the conference hall /Examination hall .
Main Library building 162 feet into 54 feet (existing library = 5186 Sq.feet ) Single door in the centre . Two emergency doors at the two ends. A 20 feet X 10 feet Balcony is to be used as a News paper stand in front of the main gate of the library. The 10 feet wide corridor connects the east block corridor and the stair case. Also connects the Front and South block through the 10 feet wide Skywalk. Connected by skywalk from from the West Block(Canteen) first floor, third flight landing. For comparison, the existing library described is 5186 square feet.
Skywalk running from North Block to South Block. 10 feet wide, two floors, excluding the ground, supported by two sets of columns. The existing pathway in the ground floor to be raised, to avoid steps in the corridors. The elevated ground after the pathway towards the central garden needs to be removed to provide more space for the open-air theatre. The existing garden between the Front entry room and the Pathway has to be redesigned. Skywalk connecting the South Block to the West Block Connected through a skywalk 10 feet wide. Single - storied, centrally supported by 1 round column. Extra Circulation area of 10' X 10' at the canteen joining point.
Second floor Conference room size 142'X 54' including a Dias 20 feet wide. Total area is 7668 square feet, suitable for an audience of 750 nos. at the rate 10 sq. feet per person. Reception area of 54' X 30'. A 10 feet wide corridor running along the whole length. 4 large - sized doors, open into the corridor Corridor connected to the staircase on east side & to the Front Block and the North Block by a 10 feet wide sky corridor. For comparison, the existing conference hall is 30 feet by 66 feet (1980 square feet )
Ground floor, Central Corridor, one side 30 feet wide rooms, and another side 22 feet wide rooms 1 st floor, 54 feet wide hall to be used for the Library, 10 feet wide corridor to one side 1 st floor, 54 feet wide Conference hall, 10 feet wide corridor to one side