StartOff ACCL [Automatic Source Changeover cum Current Limiter

zkodiyathur 254 views 3 slides Jun 18, 2016
Slide 1
Slide 1 of 3
Slide 1
1
Slide 2
2
Slide 3
3

About This Presentation

StartOff ACCL Series are designed to connect mains supply to load till mains is present. On mains failure and receiving generator power, it connects the load to DG supply. During DG operation, load drawn is monitored. If the load exceeds the allotted limit, it disrupts the supply and rechecks in int...


Slide Content

cÜxáxÇàá
100%  
Reliable Power Sharing System
another technology leap from
Series
TM 
AUTOMATIC SOURCE CHANGEOVER
j|à{ CURRENT LIMITER [ACCL]

AUTOMATIC SOURCE CHANGEOVER j|à{ CURRENT LIMITER
[Digital] Series
TM 
Features

ƒMicro-Controller based design
ƒAutomatic Source Change Over
ƒBreak before make change-over system
ƒNeutral isolation for all models
ƒCurrent Limiting function
ƒCounter for number of interruptions, thereby
protecting your valuable equipment
ƒPrevents over loading of the Generator
ƒLED / Digital indication of Status
ƒSaving in wiring and wall space
ƒEnergy Saving... Reduction of CO2 Emission
Functions

When the Mains Supply is available
¾The load is connected to the Mains supply (after initial delay) and the consumer can draw the full load as per the Sanctioned rating.
When the Mains Supply fails and Standby Generator Supply is available
¾The consumers are connected to the generator in a sequence depending upon the pre-set ‘
Initial Delay’* timing, in order to limit the sudden load on
the Generator. The Unit Monitors the Current at factory
“Set Limit”. *
¾If the Current exceeds the limit, the load is disconnected 5 times in 1 second intervals as a warning and then, automatically reconnects it after 5
minutes *. This cycle of interruptions and warning repeats 2 times and unless the load is reduced to the set limit the power supply will permanently
disconnected. The supply will be re connected only by an operator manually or when the Main / Dg supply restarts. During this period, the Consumer
is expected to switch off the non-essential loads and reduce it to within the limit.
¾When the load is within the
‘Set Limit’, the Generator continues to supply the load.
¾The supply from the Generator to the load can be restored after the Generator connection is reset by switching OFF/ON the Gen MCB. Or by pushing
the reset button on the StartOff unit.
When the Mains supply is restored
¾The Load is automatically transferred to the Mains supply after pre-set time.

LED Indicators: Over Voltage, Under Voltage, Over Load, Mains On, Generator On
Digital display: 2 line /4 line digital display : All the above status.

*
These Parameters can be Pre-Programmed depending upon requirements of Customers and also can be Re-programmed at any time.
Automatic Load Changeover Relay is a high precession system for efficient distribution
of generator power in multi-storied apartments, commercial complexes etc.

StartOff ACCL Series are designed to connect mains supply to load till mains is
present. On mains failure and receiving generator power, it connects the load to DG
supply. During DG operation, load drawn is monitored. If the load exceeds the allotted
limit, it disrupts the supply and rechecks in intervals. On reducing the load and keeping
it within the limit, load is connected to DG supply. For different applications, we have
specific models. They are with load limiter, without load limiter, transfer of load from
one phase to other phase and many additional functions.
Special Features

ƒOver Voltage (OV) / Under Voltage (UV) protection by intelligent
sensing technology.
This feature provide maximum protection to consumer’s electrical
equipment caused by voltage fluctuations or Over Voltage or
Under Voltage problems from EB and DG sides.
ƒIn both events, the StartOff ACCL automatically turn itself off and
protect the entire power supply system.
ƒUnder Voltage protection system save the Generator from
possible damages.
ƒStartOff ACCL can with-stand high voltage fluctuations up to 300v
without any damage to the unit and thereby its life is very long
compared to any other brands.
ƒBecause of the high quality of components and the quality
controlled workmanship, StartOff ACCL unit is almost maintenance
free.
The Ultimate Solution for your power distribution needs…
Maintenance Service within 24 hours!
StartOff Products are engineered to provide you
uninterrupted hassle free performance. The product
is almost maintenance free for years. Even though,
StartOff service team is equipped to provide faster
service within 24 hours in case of any trouble.

Series
TM 
SPECIFICATIONS 
Technology  Microprocessor Based 
Frequency  50 Hz 
EB  Load Current  16 A, 32 A, 40 A , 63 A, 80 A, 100 A, 125 A   * 
DG Load Current  16 A, 32 A, 40 A 63 A, 80 A, 100 A, 125 A   * 
DG Max Current Range [Limiter]  (Factory 
Set) 0.1 A to 30A   *  
Models 
 
1 Phase EB & 1 Phase DG   
3 Phase EB & 3 Phase DG 
3 Phase EB & 1 Phase DG 
Product Warranty  18 Months   ** 
Enclosure  Powder Coated Cabinet 
Display  LED / Digital 

**  
Specifications can be changed upon customer requirements.
 
12 months Replacement + 6 Months Service. 
Product Specifications
…A leap ahead
Model Range
MODEL   SPECIFICATIONS  PHASE  [EB]  PHASE [DG] MOUNTING 
SOP16LX  EB16A/DG LIMITER 200W‐1500W  SINGLE/THREE  SINGLE  PANEL 
SOP1616  EB16A/DG 16A  NON LIMITER  SINGLE/THREE  SINGLE/THREE PANEL 
SOD16LX  EB16A/DG LIMITER 200W‐1500W  SINGLE/THREE  SINGLE  DB 
SOP30LX  EB30A/DG LIMITER 200W‐5000W  SINGLE/THREE  SINGLE  PANEL 
SOP3030  EB30A/DG 30A  NON LIMITER  SINGLE/THREE  SINGLE/THREE PANEL 
SOD30LX  EB30A/DG LIMITER 200W‐5000W  SINGLE/THREE  SINGLE  DB 
SOP40LX
  EB40A/DG LIMITER 200W‐5000W  THREE  SINGLE  PANEL 
SOP4040  EB40A/DG NON LIMITER   THREE  THREE  PANEL 
SOD40LX  EB40A/DG LIMITER 200W‐5000W  THREE  SINGLE  DB 
SOP60LX  EB60A/DG LIMITER 200W‐5000W  THREE  SINGLE  PANEL 
SOP6060  EB60A/DG NON LIMITER   THREE  THREE  PANEL 
SOP80LX  EB80A/DG LIMITER 200W‐5000W  THREE  SINGLE  PANEL 
SOP8080  EB80A/DG 
NON LIMITER   THREE  THREE  PANEL 
SOP100LX EB100A/DG LIMITER 200W‐5000W  THREE  SINGLE  PANEL 
SOP100100 EB100A/DG NON LIMITER   THREE  THREE  PANEL 
SOP125LX EB125A/DG LIMITER 200W‐5000W  THREE  SINGLE  PANEL 
SOP125125 EB125A/DG NON LIMITER   THREE  THREE  PANEL 
Panther Techno Labs
Karassery [P.O], Mukkam, Pin: 673602
Calicut, Kerala, India.
Tel: +91 9447950498, +91 9744212586
Email: [email protected]
™ 
Division 
For enquiries: 
All Specifications and settings can be customized as per the requirement of specific needs