The Heart of the Compute: Understanding GPU Rig Architecture

PhilipSmithLawrence 0 views 8 slides Oct 01, 2025
Slide 1
Slide 1 of 8
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8

About This Presentation

A large-scale GPU compute infrastructure needs carefully chosen hardware and a reliable power supply to run efficiently.


These GPU rigs are built for sustained, intensive computation and must be sized and configured for high throughput and cooling demands.


A GPU is a specialized processor built ...


Slide Content

The Heart of the Compute: Understanding GPU Rig
Architecture


A large-scale GPU compute infrastructure needs carefully chosen hardware and a reliable power
supply to run efficiently.

These GPU rigs are built for sustained, intensive computation and must be sized and configured
for high throughput and cooling demands.

A GPU is a specialized processor built to move and transform memory quickly, primarily to
render images.
Originally designed for video games and visual effects, GPUs excel at parallel
processing—running thousands of calculations at the same time. That parallelism makes them
ideal not just for graphics but for scientific simulations, data analytics, and machine learning.
Think of a GPU as a calculator engineered to solve many problems simultaneously instead of
sequentially.

A complete GPU rig is a system of interdependent components, not just the GPU.
The CPU coordinates system tasks, manages I/O, and feeds data to GPUs. The motherboard
links CPU, GPUs, memory, storage, and power delivery while determining expandability and
bandwidth. RAM offers fast temporary storage for data and instructions the CPU and GPUs use;
modern rigs typically use DDR4 or DDR5 depending on platform and workload.

GPU rigs produce a lot of heat, so thermal management is essential for stability and hardware
life.
Without adequate cooling, GPUs will throttle, crash, or suffer permanent damage. Solutions
include high-airflow fans and heatsinks, and for dense or sustained loads, liquid cooling or
direct-to-chip cooling to keep temperatures in safe operating ranges.

For a single-node build, pick an NVIDIA A100 for raw GPU throughput and an AMD EPYC for
many CPU cores and PCIe lanes.
Use a server-grade motherboard that exposes those lanes and supports ECC memory. Install 256
GB of DDR4 ECC to protect long-running workloads from memory errors. Cool the system with
a custom liquid loop sized for continuous operation—multiple radiators and reliable pumps—to
keep GPU and CPU temperatures stable under sustained load.


Scaling Up: Co-located Rigs and Network
Infrastructure

Scaling from one powerful GPU rig to around 60 dramatically increases complexity.
Space layout, power distribution, and cooling needs grow nonlinearly compared to a single
system. Every added rig amplifies strain on floors, electrical panels, HVAC, and networking,
quickly exceeding typical office or small server-room capabilities.
Design must treat the fleet as a single integrated system rather than many independent
machines.

Businesses scale GPU compute by using co-location data centers—secure, purpose-built facilities
that host large computing fleets.
These centers deliver industrial-grade power, high-capacity cooling, and carrier-grade network
connectivity so you can deploy hardware without building your own facility. They’re engineered
for high-density racks, redundant systems, and strict physical and cyber security to support
continuous, heavy workloads.
GPU rigs are usually mounted in standard 42U racks, with about 10 rigs per rack in dense
setups.
Rack layout must prioritize airflow: use hot-aisle/cold-aisle containment so cool air reaches
intake fans and hot exhaust is kept separate. Proper spacing, cable management, and
containment reduce recirculation, improve cooling efficiency, and raise overall cluster
performance.
Large GPU farms draw massive, continuous power and require solid distribution hardware.
Power Distribution Units (PDUs) are indispensable for delivering power safely and predictably
to every rack. Modern PDUs provide multiple outlets, remote switching, and per-outlet current
monitoring so you can manage loads and avoid tripping breakers.

Accurate metering from PDUs lets you spot rising consumption, balance circuits, and protect
GPUs and supporting equipment from overload and brownouts.

Cable management is not cosmetic; it's essential for uptime and safety. Tidy cables keep airflow
clear, which directly affects cooling efficiency. They also reduce accidental disconnects and
signal interference. Color-coding and clear labels speed troubleshooting and maintenance,
making the whole system more reliable.
Effective communication between dozens of GPU rigs requires a network built for high
bandwidth and low latency.
High-throughput, low-latency switches (100GbE or higher) and
fiber-optic interconnects are commonly used to aggregate and route the large data flows of
distributed workloads.
Proper topology and switch capacity prevent the network from becoming
the bottleneck that limits GPU performance.

A 42U rack typically holds about ten GPU rigs, each consuming substantial power.
Power is supplied by two redundant 30A or 50A PDUs mounted at the rack rear. Network access
is provided by a 100GbE top-of-rack switch, with fiber uplinks to the core network for fast links
to other racks and external storage.
Power and network cabling are neatly routed and bundled to preserve airflow and simplify
maintenance, keeping the cluster efficient and serviceable.

Powering the Future: Renewable Energy Integration

Sixty high-performance GPU rigs create a continuous, large electricity demand and a significant
energy footprint.
Such scale requires a power supply that is both robust and sustainable, reducing reliance on the
conventional grid. Controlling and planning for this consumption is the first step to a
responsible, efficient compute infrastructure.

Solar PV and wind power can supply the large energy loads of a GPU compute facility while
cutting emissions compared with fossil fuels.
Both generate electricity directly from sunlight or wind, avoiding combustion-related
greenhouse gases. Designing the site to integrate on-site solar and wind reduces grid reliance
and lowers carbon footprint for sustained computational workloads.

Designing renewable capacity for a large GPU cluster means ensuring continuous, 24/7 power
availability.
Start by mapping the site’s resource profile: solar irradiance, wind speeds, seasonal swings, and
local weather patterns. Translate those inputs into realistic annual and hourly energy yields, not
idealized output.
Size generation so average and peak production plus storage cover the cluster’s load during
worst-case periods, including prolonged low-sun and low-wind stretches.

Specify reserve margin and redundancy to handle maintenance, equipment failures, and forecast
errors. Match generation and battery storage to the cluster’s load profile—covering nightly
demand, ramp rates, and startup surges—so operations remain uninterrupted.

Developing on-site generation means your GPU facility produces electricity where it’s used.
That cuts dependence on the grid, increases energy independence, and can lower long-term
operating costs by avoiding volatile utility rates. It also reduces transmission losses by keeping
power local, improving overall energy efficiency.

Grid interconnection is essential even when you generate power on-site.
It lets the facility draw backup power from the grid when on-site renewables and batteries fall
short. It also allows exporting surplus renewable energy back to the grid, improving economics
and reducing curtailment.
Implementing this requires meeting local utility rules, interconnection agreements, and
protections like anti-islanding.
You’ll also need bidirectional power electronics and controls to manage flows between on-site
generation, battery storage, and the grid.
Net metering credits facilities for surplus electricity they export to the grid from on-site
renewables.
When generation exceeds GPU load, the excess is sent to the grid and the facility receives a
credit. When load exceeds generation, the facility draws from the grid and uses those credits to
reduce its bill.
Net metering effectively lets the grid act as a virtual battery for short-term excess, but it does not
replace dedicated on-site battery storage for reliability or long-duration backup.

If 60 GPU rigs draw 300 kW continuously, size the solar array around 500 kW peak to cover
average daylight production and weather variability.
Add wind turbines or battery storage to
cover low-sun periods and nighttime, creating a renewable baseline that meets 24/7 compute
demand.
That hybrid setup keeps the site running reliably while maximizing clean-energy use
even on cloudy days or at night.

Ensuring Uptime: Battery Storage and Power
Stability

Renewable energy is intermittent: the sun sets and wind strength varies.
That variability makes it hard to guarantee the steady power demanding GPU compute clusters
require. Solving that gap—so compute runs continuously despite supply swings—is essential to
using renewables for critical infrastructure.
An Uninterruptible Power Supply (UPS) buffers renewable intermittency and grid outages.
It switches to backup power instantly when the primary source fails, keeping GPUs running
without interruption. A UPS prevents data loss and hardware damage from brief dips or full
power losses.

Battery storage is the core of a UPS that keeps GPU clusters running without interruption.
Advanced lithium‑ion banks store the energy needed to power racks when the grid or
renewables drop. We pick lithium‑ion for high energy density, round‑trip efficiency, and lifecycle
performance suited to large compute loads.

Depth of Discharge (DoD) is the percent of a battery’s capacity removed during use.
Deep discharges (high DoD) shorten battery cycle life. Keeping DoD shallower — avoiding
frequent near‑full drains — extends lifespan and improves long‑term reliability and economics
of the storage system.

A Battery Management System (BMS) is essential for safe, reliable operation of large battery
banks.
It monitors charge state, discharge rate, temperature, and cell health in real time. It controls
charging and discharging to maximize performance and lifespan, preventing overcharge,
overdischarge, thermal stress, and cell imbalance.
It also provides fault detection, state-of-charge/state-of-health reporting, and protection triggers
to avoid catastrophic failure.
Sizing battery capacity is essential to keep GPU infrastructure running through outages or low
renewable output.

Calculate total energy needed by multiplying the facility’s aggregate power draw (kW) by the
required backup duration (hours) to get kWh or MWh. Include inverter, transformer, and
battery system inefficiencies and minimum state-of-charge limits when converting power draw
to usable stored energy.
Factor in load diversity, planned maintenance, and potential future expansion so the battery
meets both current and near-term needs.

Validate the calculation with real-world load profiles and worst-case scenarios rather than
relying on nameplate ratings alone.

A 300 kW GPU cluster needs about 600 kWh of battery to run two hours without grid power.
Two hours gives time for orderly shutdown of workloads or starting backup generators if an
outage lasts longer. Each battery module must be managed by a Battery Management System
(BMS) that controls charge/discharge, monitors cell health, and enforces safe
depth-of-discharge limits (for example, keeping state-of-charge above ~20% to extend cycle
life).
Sustaining Performance: Monitoring, Maintenance,
and Efficiency

Sophisticated monitoring is essential to keep a large GPU cluster reliable and performant.
These tools deliver real-time metrics across hardware, power, network, cooling, and workloads
so you can see the facility’s health at a glance. Proactive monitoring detects anomalies—thermal
spikes, power draw shifts, failing GPUs, or network congestion—before they become outages.

That early detection preserves uptime, prevents cascading failures, and keeps performance
predictable over the long term.

For GPUs, monitor utilization, clock speeds, memory usage, and per‑rig temperatures.
These metrics show how efficiently GPUs handle workloads, reveal bottlenecks, and confirm
thermal safety. Detecting sudden spikes or drops early flags failing hardware or degraded
performance so you can investigate before outages occur.
Monitor energy use continuously, measuring each rig and the whole cluster in kilowatt-hours
(kWh).
Use that data to calculate actual operating costs and spot inefficient machines or configurations.
Compare consumption patterns to renewable generation and battery discharge to verify how
much load is served by on-site clean energy.
Together these metrics reveal the facility’s true power demand and how reliably the energy
system meets it.
Thermal monitoring tracks temperatures across every component and the data center
environment.
GPUs produce intense heat, so accurate temperature readings in °C are essential to prevent
overheating and keep systems stable. Monitoring tools trigger alerts when temperatures exceed
set thresholds so operators can act immediately to protect hardware and maintain uptime.

Routine maintenance is essential to keep the GPU compute facility reliable and efficient over
time.

Inspect GPUs, CPUs, motherboards, and power delivery components on a fixed schedule for
wear, overheating signs, loose connectors, and physical damage. Clean fans, heatsinks, filters,
and dust-prone areas regularly to preserve airflow and thermal performance.

For liquid cooling, check coolant levels, pump operation, tubing integrity, and heat-exchanger
surfaces for corrosion or leaks. Replace coolant and service seals per manufacturer intervals.
Test and log UPS and battery bank health regularly, using BMS telemetry and manual discharge
tests to verify runtime, charge acceptance, and cell balancing. Record findings, corrective
actions, and trends in a maintenance system to spot recurring issues and plan proactive
replacements.
Maximizing energy efficiency requires targeted optimization beyond picking efficient hardware.
Focus on workload placement, power-aware scheduling, and dynamic voltage and frequency
scaling to cut consumption without hurting throughput. Shift flexible workloads to times of
abundant renewable generation and use predictive models to avoid curtailment and reduce
costs.
Improve utilization with container orchestration, GPU sharing, and right-sizing so resources run
nearer to peak efficiency.

Combine these measures with power monitoring and automated feedback loops to continuously
find and close energy waste. Efficiency is the single biggest lever for lowering operating costs
and carbon impact in a large-scale GPU deployment.

Dynamic load balancing reallocates compute tasks across GPU rigs in real time.
It spreads work so no rigs sit idle while others are overloaded. That even distribution raises
cluster throughput and cuts energy waste. Implemented correctly, it boosts overall efficiency
and operational resilience.
Schedule non-urgent, compute-heavy tasks to run when on-site renewables are producing the
most power.

Queue batch jobs for peak solar hours or high wind periods instead of running them
continuously. This reduces draw from the grid during low-renewable times and avoids peak
energy prices, cutting costs and emissions.
Monitoring shows a sudden temperature spike in Rack 3 and a concurrent drop in GPU
utilization across several rigs.

Energy meters report higher-than-expected grid draw even though the solar array is producing
strongly. An integrated operations platform should immediately flag these anomalies and open a
maintenance ticket for Rack 3’s cooling system.

It should live-migrate or rebalance affected GPU workloads to healthy rigs to preserve compute
availability.

It should also prioritize charging battery storage with the surplus solar energy. Finally, it should
postpone non‑critical jobs until Rack 3 is fixed and renewable generation is being fully used,
keeping the site resilient and minimizing grid dependence.



For more information, please contact Philip Smith-Lawrence [email protected]