Water measurement

22,098 views 191 slides Dec 30, 2016
Slide 1
Slide 1 of 191
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53
Slide 54
54
Slide 55
55
Slide 56
56
Slide 57
57
Slide 58
58
Slide 59
59
Slide 60
60
Slide 61
61
Slide 62
62
Slide 63
63
Slide 64
64
Slide 65
65
Slide 66
66
Slide 67
67
Slide 68
68
Slide 69
69
Slide 70
70
Slide 71
71
Slide 72
72
Slide 73
73
Slide 74
74
Slide 75
75
Slide 76
76
Slide 77
77
Slide 78
78
Slide 79
79
Slide 80
80
Slide 81
81
Slide 82
82
Slide 83
83
Slide 84
84
Slide 85
85
Slide 86
86
Slide 87
87
Slide 88
88
Slide 89
89
Slide 90
90
Slide 91
91
Slide 92
92
Slide 93
93
Slide 94
94
Slide 95
95
Slide 96
96
Slide 97
97
Slide 98
98
Slide 99
99
Slide 100
100
Slide 101
101
Slide 102
102
Slide 103
103
Slide 104
104
Slide 105
105
Slide 106
106
Slide 107
107
Slide 108
108
Slide 109
109
Slide 110
110
Slide 111
111
Slide 112
112
Slide 113
113
Slide 114
114
Slide 115
115
Slide 116
116
Slide 117
117
Slide 118
118
Slide 119
119
Slide 120
120
Slide 121
121
Slide 122
122
Slide 123
123
Slide 124
124
Slide 125
125
Slide 126
126
Slide 127
127
Slide 128
128
Slide 129
129
Slide 130
130
Slide 131
131
Slide 132
132
Slide 133
133
Slide 134
134
Slide 135
135
Slide 136
136
Slide 137
137
Slide 138
138
Slide 139
139
Slide 140
140
Slide 141
141
Slide 142
142
Slide 143
143
Slide 144
144
Slide 145
145
Slide 146
146
Slide 147
147
Slide 148
148
Slide 149
149
Slide 150
150
Slide 151
151
Slide 152
152
Slide 153
153
Slide 154
154
Slide 155
155
Slide 156
156
Slide 157
157
Slide 158
158
Slide 159
159
Slide 160
160
Slide 161
161
Slide 162
162
Slide 163
163
Slide 164
164
Slide 165
165
Slide 166
166
Slide 167
167
Slide 168
168
Slide 169
169
Slide 170
170
Slide 171
171
Slide 172
172
Slide 173
173
Slide 174
174
Slide 175
175
Slide 176
176
Slide 177
177
Slide 178
178
Slide 179
179
Slide 180
180
Slide 181
181
Slide 182
182
Slide 183
183
Slide 184
184
Slide 185
185
Slide 186
186
Slide 187
187
Slide 188
188
Slide 189
189
Slide 190
190
Slide 191
191

About This Presentation

it gives knowledge about water measurement method in open Channel and pipe.


Slide Content

" WATER MEASUREMENT " 1 By Hina Bhatu

2 Why water measurement is required???? To determine the amount of water to be applied to the crops. Accurate measurement of irrigation water is necessary in field experiments on soil-water-plant relationship. Required in testing wells for their yield. Measurement of runoff from particular area and measurement steam flow are required in planning suitable soil and water conservation measure.

3 Units of measurement Water at rest (as a tank, reservoir or standing water in field) are cubic metre, litre and hectare centimetre, cubic feet, gallons, acre-inch, acre-feet . Flowing water (as in a channel or pipeline) are m 3 /s, lps, ft 3 /s, gpm.

4 Fundamental equation Based on the principle of conservation of mass and energy. Considering water as an incompressible liquid,the principle of conservation of mass leads to the continuity eq n Where; Q=discharge A=c/s area V=velocity(assumed constant across the section) Q = AV

5 Conservation of energy is stated by the bernoulli’s as that along a stream line Where; P= pressure. V=velocity. z=elevation above a datum level. g=acceleration due to gravity. =sp.weight of the liquid

6 Water measurement are the flow through open channels and flow through pipes . Measurement of flow in open channels indirect discharge methods. a. velocity-area methods. Float method Current meter b. Dilution technique c. Electromagnetic method d. Ultrasonic method

7 2. Direct discharge methods. a. Hydraulic structure Orifices Mouthpieces Weirs Notchs Flumes b. slope-area method

8 a. velocity-area methods Indirect discharge methods. The velocity of flow in the channel is measured by some mean and the discharge is calculated from the velocity and area of c/s Float method A float is a small object made of wood or other suitable material which is lighter than water. criteria A small stream in flood Small steam with rapidly changing water surface Preliminary or exploratory surveys.

9

10 A simple float moving on stream surface is called surface float. affected by surface wind and easy to use. Rod float consist of a vertical wooden rod which is weighted at the bottom to keep it vertical with its top end emerging out of free water surface when floating. It will travel with a velocity equal to mean velocity of flow.

11 Velocity is estimated by timing how long a floating object takes to travel a pre-determined distance. Observed velocity is adjusted by some factor to estimate average velocity. Determine cross-sectional flow area. Use continuity equation to estimate Q.

12 Advantages economical and simple Disadvantages not very accurate gives only approximate measure of the rate of flow

13 II. Current meter It consist of a wheel having several cups or wheel, attached to a Streamlined weight and the assembly suspended by means of cables or mounted on straight rods. The wheel in current meter is rotated by the action of flowing water. The number of revolutions of the wheel per unit time are proportional to the velocity of the flowing water. It can be used for measuring velocities in irrigation channels, stream or large river.

14 Types of current meter Anemometer and propeller velocity meter Electromagnetic velocity meters Doppler velocity meters Optical strobe velocity meters 1. Anemometer and Propeller Current Meters used for irrigation and watershed measurements. It use anemometer cup wheels or propellers to sense velocity. It does not sense direction of velocity, which may cause problems in complicated flow where backflow might not be readily apparent. For irrigation needs, this problem can be avoided by proper gage station or single measurement site selection.

15 Anemometer type current meter

16

17 2. Electromagnetic Current Meters It produce voltage proportional to the velocity. The working principle of these meters is the same as the pipeline electromagnetic flow meter. measure crossflow and are directional. Advantage :- direct analog reading of velocity; counting of revolutions is not necessary. Limitation :- use near metallic objects

18 3. Doppler Type Current Meters It determine velocity by measuring the change of source light or sound frequency from the frequency of reflections from moving particles such as small sediment and air bubbles. Laser light is used with laser Doppler velocimeters (LDV), and sound is used with acoustic doppler velocimeters (ADV). Acoustic Doppler current profilers ADCP measurements are becoming more frequent for deep flow in reservoirs, oceans, and large rivers. Most of the meters in this class are multidimensional or can simultaneously measure more than a single directional component of velocity at a time.

19 4. Optical Strobe Velocity Meters It is developed by the U.S. Geological Survey (USGS) and the California Department of Water Resources use optical methods to determine surface velocities of streams (USGS, 1965). This meter uses the strobe effect. Mirrors are mounted around a polygon drum that can be rotated at precisely controlled speeds. Light coming from the water surface is reflected by the mirrors into a lens system and an eyepiece. The rate of rotation of the mirror drum is varied while viewing the reflected images in the eyepiece. At the proper rotational speed, images become steady and appear as if the surface of the water is still. By reading the rate of rotation of the drum and knowing the distance from the mirrors to the water surface, the velocity of the surface can be determined.

20 Advantages:- No parts are immersed in the flowing stream. it can be used for high-velocity flows and for flows carrying debris and heavy sediment. It can measure large flood flows from bridges. Limitation:- However, the meter measures only the water surface velocity. It dependent upon the selection of the proper coefficient.

21 b. Dilution technique/chemical method

22 The material balance eq n QC +q 1 C 1 = (Q+q 1 )C 2 Then rate of flow Q is Q = q 1 (C 2 -C 1 ) (C -C 2 )

23 c. Electromagnetic method It is based on faraday’s principle that an emf is induced in the conductor when it cuts a normal magnetic field.

24 Where; d= depth of flow I=current in the coil n, K 1 ,K 2 = system constant It gives the total discharge when it is has been calibrated, makes it Specially suited for field situations where the c/s properties can change with time due to weed growth in , sedimentation, etc. Specific application is in tidal channels where the flow undergoes rapid changes both in magnitude as well as in direction. Accuracy ±3% Maximum channel width is 100m,and detectable velocity 0.005m/s.

25 d. Ultrasonic method It was first reported by swengel (1955). Velocity measured by ultrasonic signals.

26 If C= velocity of sound in water Where ; L = length of path from A to B v p =component of the flow velocity in the sound path=vcosθ similarly Thus,

27 Advantages It is rapid and gives high accuracy. It is suitable for automatic recording of data. It can handle rapid changes in the magnitude and direction of flow as in tidal river . The cost of installation is independent of the size of river.

28 The accuracy is limited by the factors that affect the signal velocity and averaging of flow velocity such as Unstable cross-section Fluctuating weed growth High loads of suspended solids Air entrainment Salinity and temperature change

29 2. Direct discharge methods. a. Hydraulic structure Orifices It is a small opening of any cross section on the side or at the bottom of a tank ,through which a fluid is flowing Classification of orifice According to size Small orifice (head of liquid >5d; d=depth of orifice) b) Large orifice (head of liquid <5d; d=depth of orifice)

30 According to c/s area a) Circular orifice b) Triangular orifice c) Rectangular orifice d)Square orifice According to shape of u/s edge a) Sharp-edged orifice(minimum contact with fluid) b) Bell-mouthed orifice(saturated orifice) According to nature of discharge a) Free discharging orifice b) Drowned or sub-merged orifice Fully sub-merged orifice Partially sub-merged orifice

31 Flow through on orifice The section cc is approximately at a distance of half of dia. of the orifice. At this section, the stream line are straight and parallel to each other and perpendicular to the plane of the orifice This section is called venacontract.

32 Let the flow is steady and at a constant head H. applying Bernoulli's equation But z 1 =z 2 now and (v 1 <<< v 2 and tank area is very large compared to the area jet)

33 Hydraulic co-efficient The value c v of varies from 0.95 to 0.99 for different orifices, depending on the shape, size of the orifice and on the head under which flow take place Co-efficient of velocity (c v )

34 Co-efficient of contraction(c c ) The value c c of varies from 0.61 to 0.69 for different orifices, depending on the shape, size of the orifice and on the head under which flow take place

35 Co-efficient of discharge(c d ) The value c d of varies from 0.61 to 0.65 for different orifices,

36 Flow through large orifice Note:- in case of small orifice, the velocity in the entire c/s of the jet is consider constant then discharge can be calculated by But in large orifice the velocity is not constant Discharge through large rectangular orifice Consider a orifice in one side of the tank discharging freely into atmosphere under a constant head H. Let, H 1 = height of liquid above top edge of orifice H 2 = height of liquid above bottom edge of orifice b = breadth of orifice d = depth of orifice = H 2 - H 1 c d = co- efficient of discharge

37

38 Discharge through elementary strip Integrating above equation bet n H 1 and H 2 Now ,Total discharge = Q

39 Discharge through fully sub-merged orifice It is one which has its whole of the outlet side sub-merged under liquid. Let, H 1 = height of water above the top of the orifice on the u/s side. H 2 = height of water above bottom of the orifice H = difference in water level b = width of orifice c d = co- efficient of discharge

40 Height of water above the center of orifice on u/s side Height of water above the center of orifice on d/s side Now applying Bernoulli's eq n (z 1 =z 2 ) and And V 1 is negligible

41

42 Discharge through partially sub-merged orifice It is one which has its outlet side partially sub-merged under liquid. The upper portion behaves as orifice discharging free & lower portion behaves as a partially sub-merged orifice. Only large orifice behaves as a partially sub-merged orifice.

43 Total discharge = discharge through free + sub-merged portion Discharge through sub-merged portion, Discharge through free portion,

44 B. Mouthpieces A mouthpiece is a short length of a pipe which is two to three times its diameter in length fitted in a tank or vessel containing the fluid Classification of Mouthpieces According to their position with respect to tank a) External Mouthpieces b) Internal Mouthpieces According to shape a) Cylindrical Mouthpieces b) Convergent Mouthpieces c) divergent Mouthpieces d) Convergent-divergent Mouthpieces

45 According to nature of discharge at outlet/re-entrant/borda’s (only for internal) a) Mouthpieces running full If jet of liquid after expand and fills the whole mouthpiece b) Mouthpieces running free If jet of liquid after contraction does not touch the side of mouthpiece

46 Discharge through external cylindrical mouthpiece Let, H = height of liquid above the centre of mouthpiece v c = velocity of liquid at c-c section a c = area of flow at vena- contracta v 1 = velocity of liquid at outlet a 1 = area of mouthpiece at outlet c c = co- efficient of contraction

47 Applying continuity eq n at c-c and (1)-(1) But Taking c c = 0.62

48 The jet of liquid from section c-c suddenly enlarges at section (1)-(1). Due to sudden enlargement , there will be a loss of head, h L But

49 Now applying Bernoulli's eq n to point A and (1)-(1) Where, z A = z 1 , v A is negligible

50 Theoretical velocity of liquid at outlet is = Co-efficient of velocity for mouthpiece C c for mouthpiece = 1 . area of jet of liquid at outlet = area of mouthpiece at outlet Value of C d for mouthpiece > Value of C d for orifice Discharge through mouthpiece will be more.

51 Discharge through internal or re-entrant or borda’s mouthpiece i) Borda’s mouthpiece running free If the length of the tube is equal to its dia., the jet of liquid comes out from mouthpiece without touching the sides of the tube is known as running free Let, H = height of liquid above the mouthpiece v c = velocity through mouthpiece a c = area of contracted jet in the mouthpiece a 1 = area of mouthpiece

52 Where, a = area of mouthpiece h = distance of c.g. of area a from free surface = H According to Newton's 2 nd law, net force = rate of change of momentum Initial velocity of fluid=0 & final velocity of fluid = v c ………(i) ………(ii)

53 Equating eq n (i) & (ii) Now applying Bernoulli's eq n to free surface of liquid and section (1)-(1) Taking the centre line of mouthpiece as datum, we have ………(iii)

54 Substituting the value v c in eq n (iii) There is no head loss, c v = 1

55 ii) Borda’s mouthpiece running full If the length of the tube is about 3 times its dia., the jet of liquid comes out with dia. equal to the dia. of mouthpiece at outlet is known as running full Let, H = height of liquid above the mouthpiece v c = velocity through mouthpiece a c = area of the flow at c-c a = area of mouthpiece v 1 = velocity at outlet

56 The jet of liquid after passing through c-c, suddenly enlarges at section (1)-(1).Due to sudden enlargement ,there will be a loss of head Applying continuity eq n at c-c and (1)-(1) …………..(i) Substituting the value v c in eq n (i)

57 Now applying Bernoulli's eq n to free surface of liquid and section (1)-(1) Taking the centre line of mouthpiece as datum, (Actual velocity)

58 Co-efficient of velocity c v C c for mouthpiece = 1 . area of jet of liquid at outlet = area of mouthpiece at outlet

59 Discharge through convergent – divergent mouthpiece If a mouthpiece converges up to vena- contracta and then diverge is called convergent – divergent mouthpiece. There is no sudden enlargement of the jet, the loss of energy due to sudden enlargement is eliminated. And c d =1 Let , H = head of liquid over the mouthpiece

60 Now applying Bernoulli's eq n to free surface of liquid and section c -c Taking the centre line of mouthpiece as datum, ………(i)

61 Now applying Bernoulli's eq n at section c –c & (1) – (1) From eq n (i)

62 Applying continuity eq n at c-c and (1)-(1) Where , a c = area at vena- contracta

63 C. Weirs Classification of Weirs According to shape of opening a) Rectangular Weir b) Triangular Weir c) Trapezoidal Weir( Cippoletti Weir) According to shape of crest a) Sharp–crested Weir b) Broad-crested Weir c) Narrrow-crested Weir d) Ogee –shaped Weir It is generally in the form of vertical wall ,with a sharp edge at the top , running all the way across the open channel.

64 The edge over which water flows is called the crest. The height of the weir between the crest and the channel bottom is called the crest height. The height of the discharge over the crest is called the nappe. The air space under the nappe, downstream from the weir, is called the ventilation.

65 Factors Affecting Flow over Weirs • The head • Fluid properties and Temperature Effects • Approach and tail water conditions • Weir Geometry • Measurement inaccuracies

66 Advantages Capable of accurately measuring a wide range of flows Tends to provide more accurate discharge ratings than flumes and orifices Easy to construct Can be used in combination with turnout and division structures Can be both portable and adjustable Most floating debris tends to pass over the structure

67 Disadvantages Relatively large head required, particularly for free flow conditions. This precludes the practical use of weirs for flow measurement in flat areas. The upstream pool must be maintained clean of sediment and kept free of weeds and trash, otherwise the calibration will shift and the measurement accuracy will be compromised

68 Short crested weirs In general, short-crested weirs are those overflow structures, in which the streamline curvature above the weir crest has a significant influence on the head-discharge relationship of the structure. Weir sill with rectangular control section

69 Limits of application The practical lower limit of h, is related to the magnitude of the influence of fluid properties, to the boundary roughness in the approach section, and to the accuracy with which h, can be determined. The recommended lower limit is 0.09 m; The crest surface and sides of the control section should have plane surfaces which make sharp 90-degree intersections with the upstream weir face; The bottom width of the trapezoidal approach channel should be 1.25 b,; The upstream head h1, should be measured 1.80 m upstream of the down streamweir face. Consequently, h, should not exceed half of this distance, i.e. 0.90 m; To obtain modular flow the submergence ratio h,/h, should not exceed 0.20.

70 V-Notch Weir it is also called Thomson Weir or Gourley Weir. This weir features a weir plate standing vertical to the flow direction with a sharp-edged triangular cutout . The backwater level in front of the weir is directly proportional to the flow volume. Due to its special cutout the V-Notch weir is especially suitable for small volume measurement (0.05 l/s - 30 l/s; 0.79 - 475.59 gpm ). it is primarily suitable for the evaluation of clean media like spring water, small sewage plant’s drains or partially even for volume measuring of percolating waters in dumps

71 Prerequisites no backwater low oncoming flow velocity no sedimentation clean media without slubs , fibers or similar

72 Limits of application The head over the weir crest should be at least 0.03 m and should be measured a distance of 3.00 m upstream from the weir. The notch should be at least O. 15 m from the bottom or the sides of the approach channel. The approach channel should be reasonably straight and level for 15.0 m upstream from the weir. To obtain modular flow the submergence ratio h2/h1 should not exceed 0.30.

73 Advantages low costs for the needed measurement technique accurate measurement results (even at low volumes) easy to verify Disadvantages partially high mechanical expenses needed to realize the necessary hydraulic conditions no measurement in polluted or sediment carrying media no measurement of very high volumes

74

75 D. Notchs It may be defined as an opening in the side of a tank or a small channel in such a way that the liquid surface in the tank or channel is below the top edge of the opening. Classification of Notch According to shape of opening a) Rectangular Notch b) Triangular Notch c) Trapezoidal Notch d) Stepped Notch According to the effect of the sides on the nappe a) Notch with end contraction b) Notch without end contraction or suppressed

76 Big in size. Small in size. Made of concrete or masonary structure. Made of metallic plate. Weirs Notchs

77 Discharge over a rectangular notch or weir Let , H = head of water over the crest L = length of the notch or weir Consider an elementary horizontal strip of water of thickness dh and length L at a depth h from the free surface of water. Are of strip =L * dh

78 The discharge dQ through strip is Now total discharge Q

79 Discharge over a triangular notch or weir Let , H = head of water above v-notch θ = angle of notch Consider a horizontal strip of water of thickness dh at a depth of h from the free surface of water. From fig. we have,

80 Discharge ,dQ through the strip is

81 Total discharge Q is

82 For a right angled V- notch , if c d =0.6

83 Advantages of triangular notch or weir over rectangular notch or weir The expression for discharge for V- notch or weir is very simple . For measuring low discharge, a triangular notch gives more accurate results than a rectangular notch. In triangular notch , only 1 reading i.e. H is required for computation of discharge. Ventilation of triangular notch is not necessary.

84 Discharge over a trapezoidal notch or weir Total discharge = discharge through rectangular notch or weir + discharge through triangular notch or weir Let , H = height of water over the notch L = length of crest of notch = co –efficient of discharge for rectangular portion = co –efficient of discharge for triangular portion

85 Discharge through rectangular portion ABCD Discharge through 2 triangular notches FDA & BCF = discharge through single triangular notch Discharge through trapezoidal notch or weir = Q 1 + Q 2

86 Discharge over a stepped notch Discharge through stepped notch = sum of discharge through different rectangular notch Let , H 1 = height of water above the crest of notch (1) L 1 = length of notch (1) H 2 , L 2 & H 3 , L 3 are corresponding value for notch (2) &(3) respectively. c d = co –efficient of discharge for all notch

87

88 Cipolletti weir or notch Cipolletti weir is trapezoidal weir, which has side slopes of 1:4(H:V)

89 The discharge through a rectangular weir with two end contractions is Let the slope is given by θ/2, now discharge through V- notch is

90 The discharge through cipolletti weir is If velocity of approach , v a is to be taken in to consideration

91 Discharge over a broad –crested weir A weir have wide crest is known as broad –crested weir Let , H = height of water over the crest L = length of the crest h = head of water at the middle of weir which is constant v = velocity of flow over the weir If 2l > H , the weir is called broad –crested weir

92 Now applying Bernoulli's eq n to the still water surface on the u/s side and running at the end of weir The discharge over weir is ………….(i)

93 The discharge will be max m , if (Hh 2 –h 3 ) max m Substituting value of h in eq n (i)

94

95 Discharge over a narrow –crested weir If 2l < H , the weir is called narrow –crested weir . It is similar to Rectangular weir or notch

96 Discharge over a ogee weir In which the crest of the weir rises up to max m height of 0.115 * H where H = height of water above inlet of weir The discharge through ogee weir is same as that of rectangular weir

97 Discharge over submerged weir or drowned weir When the water level on the d/s side of weir is above the crest of the weir ,then the weir is called to be submerged weir drowned weir Divided in to two portion. the portion bet n u/s and d/s water surface may be treated as free weir and portion bet n d/s water surface and crest of weir as a drowned weir Let , H = height of water on the u/s of the weir h = height of water on the d/s of the weir

98 Then , Total discharge,

99 E. Flumes Flumes are shaped open channel flow sections in which flow is measured DESCRIPTION 1. Flumes force flow to accelerate Converging sidewalls Raised bottom Combination 2. Flumes force flow to pass through critical depth Unique relationship between water surface profile and discharge

100 Advantages Minimal drop in pressure. Enables measurement in a large range of flow. The flow rate in flumes is usually high enough to prevent sedimentation; they are therefore self-cleaning. Provides a reliable measurement in free flow and submerged flow conditions.

101 Disadvantages Installation is usually expensive. Installation requires extremely careful work. Requires a secure watertight base. Flow at the entrance must be evenly distributed, with little turbulence, to produce accurate measurements.

102 Two basic classes of flumes 1. Long throated flumes Parallel flow lines in control section Accurately rate with fluid flow analysis 2. Short throated flumes Curvilinear flow in control section Calibrated with more precise measurement devices Types of flume

103 Long throated flumes ( Replogle flume ) Long-throated flumes have one-dimensional flow in the control section -- Long-throated means long enough to eliminate lateral and vertical contraction of the flow at the control section…streamlines are essentially parallel Can be calibrated using well-established hydraulic theory No laboratory testing needed Calculations are iterative, so computer models that do the calculations have made long-throated flumes reasonable to implement in recent years

104 Classified under the term ‘long-throated flumes’ are those structures which have a throat section in which the streamlines run parallel to each other at least over a short distance. Because of this, hydrostatic pressure distribution can be assumed at the control section. This assumption allowed the various head-discharge equations to be derived, but the reader should note that discharge coefficients are also presented for high H1/L ratios when the streamlines at the control are curved. Long-throated flumes are the measurement device of choice for most open channel applications, having significant advantages over Parshall flumes and other traditional devices.

105 These older devices were laboratory-calibrated, because the flow through their control sections is curvilinear. In contrast, streamlines are essentially parallel in the control sections of long-throated flumes, making them ratable using straightforward hydraulic theory. The crest level of the throat should not be lower than the dead water level in the channel, i.e. the water level downstream at zero flow. The throat section is prismatic but the shape of the flume cross-section is rather arbitrary, provided that no horizontal planes, or planes that are nearly so, occur in the throat above crest (invert) level, since this will cause a discontinuity in the head-discharge relationship.

106 The flume comprises a throat of which the bottom (invert) is truly horizontal in the direction of flow. Advantages Minimal head loss required , Economical construction techniques Adaptable to existing control sections Variety of construction materials Rating table accuracy of ±2% Choice of various shapes and configurations Calibration based on the as-built dimensions User-friendly software WinFlume Proven track record Accurate over the entire flow range Minimal problems with trash and debris Ability to pass sediment

107

108 Long-Throated Flumes (Ramp Flumes)

109 Limits of application The practical lower limit of h, is related to the magnitude of the influence of fluid properties, boundary roughness, and the accuracy with which h, can be determined. The recommended lower limit is 0.07 L. To prevent water surface instability in the approach channel the Froude number Fr = v1/(gA1/B1)² should not exceed 0.5. The upper limitation on the ratio H1/L arises from the necessity to prevent streamline curvature in the flume throat. Values of the ratio H1/L should be less than 1.0 The width B, of the water surface in the throat at maximum stage should not be less than L/5. The width at the water surface in a triangular throat at minimum stage should not be less than 0.20 m.

110 Trapezoidal Replogle flume Rectangular Replogle flume

111 Other flumes a) H-Flumes H flumes are a hybrid between flumes and weirs. H flumes can measure a wide variety of flows, from very low to extremely high volumes.  H flumes were designed in the mid-1930s by the USDA Agricultural Research Service The measuring point of the H flume, selected during development, is in the draw down effect, this means that H flumes are very sensitive to slight errors in measuring point position.   A straight uniform approach must be provided that matches the inlet width of the H flume.  H flumes require a non-impeded discharge so that there can be no submergence.

112 H flumes are capable of monitoring flows that vary over wide ranges with a high degree of accuracy. H flume is capable of providing accurate measurement for applications with flow ranges of 100:1 or more. On natural streams where it is necessary to measure a wide range of discharges, a structure with a V-type control has the advantage of providing a wide opening at high flows so that it causes no excessive backwater effects, whereas at low flows its opening is reduced so that the sensitivity of the structure remains acceptable.

113 To serve this purpose the U.S. Soil Conservation Service developed the H-type flume, of which three geometrically different types are available HS flumes H flumes HL flumes

114 Operating principle An H flume operates according to the Venturi principle. Due to lateral restrictions, the flume restricts the flow area, causing the water level upstream from the throat to rise. The flow can be obtained by simply measuring the water depth, because this depth varies proportionally with flow. Applications An H flume was developed to measure the flow of irrigation water from small catchment areas and surface water. it is generally used to measure the flow of irrigation water, slow- flowing watercourses and water in sewer systems.

115 The geometry and operating principle of an H flume make it a very useful tool for measuring the flow of water that contains solids. This type of flume can measure a variety of different flows and provides good precision. Ranges of measurement H flumes can be used to measure flowrates between 0.3981 m3 per day, for an Hs flume 122 mm (0.4 ft) high, and 286,251 m3 per day, for an HL flume 1219 mm (4 ft) high.

116 HS flumes Of this ‘small’ flume, the largest size has a depth D equal to 0.305 m (1 ft) and a maximum capacity of 0.022 m ³ /s. HS flumes are typically recommended for lower flows not exceeding 0.8 cfs.

117 2. H flumes Of this ‘normal’ flume, the largest size has a depth D equal to 1.37 m (4.5 ft) and a maximum capacity of 2.36 m ³ /s. Fiberglass H flumes are available in a variety of sizes and can be used to measure flows ranging from zero to 80 cfs.

118

119 HL flumes The use of this ‘large’ flume is only recommended if the anticipated discharge exceeds the capacity of the normal H- flume. The largest HL-flume has a depth D equal to 1.37 m (4.5 ft) and a maximum capacity of 3.32 m ³ /s. The 4.0’ HL flume may be recommended for larger flows up to 111 cfs.

120

121 Advantages of H flumes Three types of flumes—HS, H, and HL—are available for small-, medium-, and high-discharge rates, respectively. They have different specifications to suit various ranges of water flow. The shape of flume provides the following distinct advantages that favor its use under a variety of flow conditions (USDA 1979):  The increase of throat opening with the rise of stage facilitates accurate. 2. Measurement of both low and high flow of water.  3. The converging section of flume makes it self-cleaning because of increased velocity.

122 Consequently, the flume is suitable for measuring flows having sediment in suspension and low bed-loads.  4. It is simple to construct, rigid and stable in operation, and requires minimal maintenance for retaining its rating.  5. Its installation is simple and is generally not affected by the steepness of the channel gradient.

123 Submergence of H flume Flumes should be installed with free outfall or no submergence wherever possible. If submergence occurs, the free discharge head (H) can be computed by using the following equation, presented in non-metric units to be consistent with those given in USDA (1979): H = d 1 /{1 + 0.00175[exp (d 2 /d 1 ) 5.44 ]} Where, H is the free flow head (in ft) d 1 is the actual head with submergence (in ft) d 2 is the tail water depth (in ft) above flume zero head and 0.15 < d 2 /d 1 < 0.90.

124 H flumes Discharge equations FLUME SIZE EQUATION HS-Type 0.4' Q=294.50*H^2.23815 0.6' Q=322.569*H^2.2405 0.8' Q=345.10*H^2.23173 1.0' Q=366.13*H^2.22258 H-Type 0.5' Q=767.5*H^2.31 0.75' Q=830.3*H^2.31 1.0' Q=875.2&H^2.31 1.5' Q=947.0*H^2.31 2.0' Q=1000.8*H^2.31 3.0' Q=1081.6*H^2.31 4.5' Q=1166.9*H^2.31 HL-Type 4.5' Q=1156.46&H^2.31716

125

126 Evaluation of discharge All three types of H-flumes have a rather arbitrary control while an upstream piezometric head ha is measured at a station in the area of water surface drawdown. Under these circumstances, the only accurate method of finding a head-discharge relationship is by calibration in a hydraulic laboratory. Based on this calibration, an empirical formula, expressing the discharge in m ³ /s as a function of the head ha in metres, could be established of the general form log Q = A + B log h a + C[log h a ]² ……………(1) Values of the numbers A, B, and C appear in Table

127

128 Modular limit The modular limit is defined as the submergence ratio h2/ha which produces a 1% reduction from the equivalent modular discharge as calculated by Equation …..(1) Results of various tests showed that the modular limit for HS- and H-flumes is h2/ha = 0.25, for HL-flumes this limit is 0.30. Rising tail water levels cause an increase of the equivalent upstream head ha at modular flow. Because of the complex method of calculating submerged flow, all HS- and H-flumes should be installed with a submergence ratio of less than 0.25 (for HL-flumes 0.30).

129 Limits of application a. The inside surface of the flume should be plane and smooth while the flume dimensions should be in strict accordance with Figure. b. The practical lower limit of ha, is mainly related to the accuracy with which ha, can be determined. For heads less than 0.06 m, point gauge readings are required to obtain a reasonably accurate measurement. The lower limit of ha for each type of flume can be read from Tables 7.13 to 7.15. c. To obtain modular flow the submergence ratio h2/ha should not exceed 0.25. d. To prevent water surface instability in the approach channel, the Froude number Fr, = v1/(gA1/B)^1/2 should not exceed 0.5.

130 b) Parshall flume The Parshall flume was designed in the later 1920s to measure the flow of irrigation water. It is often used to measure the flow of wastewater, for permanent or temporary installations DESCRIPTION A Parshall flume consists of a converging section, a throat section and diverging section. The crest of the throat section is tilted downstream. In other words, there is a sill between the horizontal crest and converging section and the crest of the throat section.

131 For channels smaller than 2.44 m (8 ft), the inlet of the converging section may be rounded, and larger channels may have vertical walls at a 45° angle. To prevent erosion due to water fall, the diverging section is usually extended by means of vertical walls, and the angle of these walls will be steeper than the angle of the walls of the diverging section Dimensions are standardized for each flume Not hydraulic scale models of each other A 12 ft flume is not simply 3 multiply by a 4 ft flume Designated by throat width Measure 0.01 cfs with 1 inch flume Measure 3000 cfs with 50 foot flume

132 Relate H a (or H a and H b ) to discharge with rating equation, or consult appropriate chart Flow rate through the critical section is a function of the upstream head, acceleration of gravity, and the control section size Operating principle A Parshall flume operates according to the Venturi principle. Due to lateral restrictions, the flume restricts the flow area, causing the water level upstream from the throat section to rise. A sudden or steep drop in water level at the throat section creates an increase in flow velocity.

133 The flowrate can be obtained simply by measuring the water depth, because it has been established that depth varies proportionally with flow. Applications initially developed to measure flow in natural open channels such as rivers, streams, drainage ditches, etc., widely used to measure flow in man-made open channels, such as storm and domestic drainage systems, sewage treatment plant inlets and outlets, etc. Because of its geometry and operating principle, a Parshall flume is extremely effective for measuring the flow of water that contains solids. Because it creates little loss of depth, it can be easily adapted to existing sewer systems.

134

135 Dimensions The dimensions of a Parshall flume are defined by the width of constriction

136 CLASSES OF PARSHAL FLUMES On the basis of the throat width, Parshall flumes have been classified into three main groups. Very small - 25.4 mm to 76.2 mm. (ii) Small 152.40 mm to 2438.4 mm. (iii) Large 3048 mm to 15240 mm.

137 1. VERY SMALL FLUMES Discharge capacity ranges from 0.09 l/s to 32 l/s. Turbulence makes difficult to read H b – gauge H c – gauge included downstream end of diverging section to provide readings during submergence H c – gauge readings are converted to H b – gauge by using a graph & used to determine discharge .

138 2. SMALL FLUMES Discharge capacity ranges from 0.0015m 3 /s to 3.95 m 3 /s Length of side wall of converging section, A, of (1ft -8ft) throat width (m) is given as; Where; b c = throat width (m) H a – gauge located at distance of a = upstream from the end of the horizontal crest H b – gauge location is the same in all small flumes (X = 2inch upstream from the low point in the sloping throat floor ) & (Y= 3 inch above it)

139 3. LARGE FLUMES (10 ft up to 50 ft) Discharge capacity ranges from 0.16m 3 /s to 93.04 m 3 /s Length of side wall of converging section is longer than in small flumes H a – gauge located at distance of m upstream from the end of the horizontal crest H b – gauge location is the same in all large flumes (X = 12inch upstream from the floor at downstream edge of the throat ) & (Y= 9 inch above it)

140

141 ADVANTAGES Relatively low head loss (1/4 of sharp crested weir) Handle some trash and sediment Well accepted May be mandated Many sizes are commercially available DISADVANTAGES Complicated geometry for construction Tight construction tolerances Aren’t amenable to fluid flow analysis BoR does not recommend for new construction

142 Range of measurements Parshall flumes can measure flows varying from 70.7 m3 per day, for a 76 mm (3 in) channel, to 8,038,656 m3 per day, for a 15.24 m (50 ft) channel. For the purposes of this document, only data that apply to channels with dimensions between 76 mm (3 in) and 36.57 m (12 ft), have been included.

143 c) Palmer-Bowlus Flume A Palmer-Bowlus flume was designed in the 1930s for use as a flume that can be inserted in an existing channel with a slope of less than 2 %. Description This flume is rounded to create a restriction and produce a greater flow velocity in the throat of the flume. It is a Venturi type flume with a uniform throat. The length of the throat is equal to the diameter of the corresponding flume. Different types of restrictions have been developed, but the restriction most frequently used is trapezoidal in shape.

144 It is usually made of prefabricated fibreglass that is reinforced with plastic. Although rare, also made of stainless steel. A Palmer-Bowlus flume is manufactured in sizes ranging from 102 mm (4 in) to 1067 mm (42 in). Operating principle Vertical and lateral restrictions on the flume reduce the flow area, causing the water level upstream from the throat section to rise, which is followed by a drop in water level in the throat section, resulting also in an increased flow velocity. Flowrate can be determined simply by measuring water depth upstream from the flume, since it has been established that variations in depth are proportional to flow.

145 Applications it is designed to measure flow in sewer systems and existing channels, a Palmer-Bowlus flume is not a temporary device. In fact, the difference in measurement between a minimum and maximum flow is relatively small if a system is expanded, the size of the flume must also be changed. Like all flumes, a Palmer-Bowlus flume is an effective tool for flow measurement of water that contains solids. It is also relatively easy to install because it does not require a crest differential upstream or downstream.

146 Dimensions Dimensions of a Palmer-Bowlus flume depend on the diameter of the channel in which it is installed. SHAPE OF A PALMER-BOWLUS FLUME ACCORDING TO LUDWIG

147 Ranges of Measurement Palmer-Bowlus flumes can measure flows varying between 2.4 m3 per day, in the case of a 102 mm (4 in) flume, and 49,200 m3 per day, in the case of a 762 mm (30 in) flume. d) Leopold-Lagco flume The Leopold-Lagco flume was developed in the early 1960s and introduced on the market in 1965 by F.B. Leopold Company Inc. of Pennsylvania.

148 Description It has a round shape. The purpose of its rounded shape is to create a restriction in the conduit, which causes a greater flow velocity in the throat of the flume. This flume operates according to the Venturi principle. The throat is uniform and its length is equal to the diameter of the channel for which it was designed. its throat section has a rectangular shape. It consists of three sections: a converging section, throat section and diverging section

149 There are three models: permanent installation model: there is a slight extension of the converging and diverging sections; insertion model: outer radius of the flume corresponds to the inner radius of the channel in which it is to be installed; cutthroat model: the diverging section is not as high. This flume is used on a temporary basis only. The inner surface of the flume must be made of material that is smooth and free of irregular edges. The outer surface is made of a material that facilitates adhesion to a concrete surface.

150 The flume is made of fiberglass in standard sizes varying between 152 mm (6 in) and 1219 mm (48 in). Operating principle Due to vertical and lateral restrictions, a Leopold-Lagco reduces the flow area, causing the water level upstream from the throat section to rise, followed by a drop in water level and an increased flow velocity. Flow can be determined by simply measuring the water level upstream from the flume, since it has been established that depth varies according to flow. Literature provides no information about use of this flume in submerged flow conditions and no correction formula. Use in only free flow conditions is therefore recommended.

151 Applications It is used as a main measuring device on a temporary or permanent basis. Like all flumes, it is an effective tool for measuring the flow of water that contains solids. Due to their relatively small volume, flumes with a diameter of 381 mm (15 in) or less can be inserted in a standard sewer manhole, without the need to modify access. It is relatively easy to install because there is no need for a required distance from the bottom of the channel in which it is inserted.

152 Dimensions The dimensions of a Leopold-Lagco flume are a function of the diameter of the conduit in which it is installed.

153 Range of measurements Leopold-Lagco flumes can measure flows varying between 84.2 m3 per day, for a 152 mm (6 in) flume, and 108,445 m3 per day, for a 1219 mm (48 in) flume. e) Cutthroat flume It was developed in the mid-1960s by Utah State University Water Resources Laboratory. It is used to measure flow in locations where there is no slope or very little slope.

154

155 Description A cutthroat flume consists of a converging section and diverging section. The control section (W) does not have parallel sides because the flume consists only of a converging and diverging section. The bottom of the entire length of the flume is flat. For flumes that are less than 1.37 m (4.5 ft) long (L) and 15.2 cm (0.5 ft) wide in the control section (W), the inlet of the converging section may be rounded. For larger flumes, the inlet of the converging section may have vertical walls at a 30° angle. To prevent erosion due to water fall, the diverging section is usually extended by means of vertical walls, and the angle of these walls is steeper than the angle of the walls in the diverging section.

156 Operating principle Cutthroat flumes operate according to the Venturi principle. Due to the lateral shape of its walls, the flume restricts the flow area, which causes the water level upstream from the control section to rise, followed by a sudden and significant drop of the water level in the control section, accompanied by an increase in flow velocity. The flow can be determined by simply measuring the water depth, because depth varies proportionally with flow. Although this flume can be used in submerged flows, use in free flow conditions is strongly recommended

157 Applications It was developed to measure flow in open natural channels, such as rivers, streams, drainage ditches, etc. with a small slope. It has been the subject of several studies that demonstrate its effectiveness as a measuring device in sewer systems and water treatment plants. The geometry and operating principle of a cutthroat flume make it an effective device for measuring flow in water that contains solids. Because this flume causes only a small loss of head and requires no difference in height between the bottom of the channel and base of the flume, it is relatively easy to adapt to existing sewer systems.

158 A cutthroat flume is simple and inexpensive to manufacture. It is also perfectly suited to a temporary measurement system. Dimensions The dimension of a cutthroat flume is defined by the total length of the flume (L) and the width of the control section (constriction) (W).

159

160

161 Range of measurements Cutthroat flumes can measure flows varying between 32 m3 per day, for a flume 457 mm (1.5 ft) long with a constriction of 25 mm (0.083 ft), and 210,555 m3 per day, for a flume 2,743 mm (9 ft) long with a constriction of 1,829 mm (6 ft). Disadvantages when it compared with long-throated flumes: The discharge coefficient C d is rather strongly influenced by H 1 and H 2 ; The modular limit varies with H 1 and has a lower value; The control section can only be rectangular; C d value has high error of about 8 percent.

162 f) Trapezoidal Flumes These are some what similar to Parshall flumes but different in shape. These were originally developed in Washington State College and as such are referred to WSC flume . Advantages 1) A large range of flows can be measured with a comparatively small change in head ; 2) Sediment deposits in the approach does not change the head discharge relationship noticeably ; 3) Extreme approach conditions seem to have a minor effect upon head discharge relationship;

163 4) The flumes will operate under greater submergence than rectangular shaped ones without corrections for submergence; 5) The trapezoidal shape fits the common channel sections more closely than a rectangular one.

164 Schematic view of truncated flume for earthen channel. Shortening of the full length structure is possible by deleting the diverging section and the tailwater section if the head loss over the section exceeds 0.4 times the head causing the flow, as measured from the crest of the throat section. Such a structure is called a truncated flume. g) Truncated Flume

165 Triangular throated flumes are adapted to measure a wide range of discharges, including low flows like return flows to drainage system operational spillage from irrigation systems. It also permits wide variations in the flow rate. The ratio between the maximum and minimum flow is high in case of triangular throated flume. h) Triangular Throated Flume

166 Schematic view of triangular throat flume .`

167 b. Slope-Area Method This consists of using the slope of the water surface in a uniform reach of channel and the average cross-sectional area of that reach to give a rate of discharge. The discharge may be computed from the Manning formula: where: Q = discharge (m 3 /s) A = mean area of the channel cross section (m 2 ) Rh = mean hydraulic radius of the channel (m) S = energy slope of the flow n = a roughness factor depending on the character of the channel lining

168 Measurement of flow in pipe measuring the time required for the flow to fill a container of known volume. Volumetric measurement Advantages It is very simple and requires little equipment. Disadvantages where the flow rate is not uniform over a period of time, frequent measurements are to be taken to get accurate data

169 FLOW RATE MEASUREMENTS The different methods used for measuring the rate of flow in pipes are: Venturimeters Orifice plate Pitot tube Elbow meter Co –ordinate method

170 1. Venturi Meters. It consists of converging and expanding section of short length. It is useful for measuring the flow of water in pipes under pressure. It utilises the principle that the flow passing through a constricted section of pipe is accelerated and the pressure head lowered. The drop in the pressure head is measured by providing openings in the Venturi meter at the points shown in the figure and connecting these openings to a U-tube manometer. Considering points (1) and (2) with cross-sectional areas A 1 and A 2 respectively and assuming horizontal pipe, from Bernoulli theorem, neglecting friction

171

172 The pressure head difference is indicated by the manometer reading, h, hence, where, ρ M is the density of the gauge fluid. Q = V 1 A 1 = V 2 A 2 By continuity,

173 Substituting for V 2 in terms of V 1 yields Solving for V 1 Hence, = coefficient of discharge

174 2.Orifice plate Its function is similar to the venturi meter. major difference between the devices lies in the fact that, downstream of the orifice piate , the flow area expands instantaneously while the fluid is unable to expand at the same rate. This creates a 'separation zone' of turbulent eddies in which large energy losses occur. C d is considerably lower than that for the Venturi meter. Advantages its lower cost and its compactness.

175 The orifice can be put at the end of the pipe (Fig.) and is known as pipe orifice. The ratio of the orifice diameter to the pipe diameter should be between 0.5 and 0.8 and is selected in such a way that the pipe flows full.

176 The discharge is computed using the equation. Where a = area of orifice h = head of flow measured from center of pipe

177 3.Pitot tube The pitot tube is an open L shaped tube useful for measuring velocity of flows in an open channels as well as in pipes. The velocity at point 2 immediately at the nose of the tube is zero as water is at rest here. The Pitot tube gives the velocity at the point at which the open end is placed

178 The use of the Pitot tube for measuring flow when the pipe is flowing under pressure the static pressure of the water is to be taken into consideration. Fig. 4.18 illustrates how this is done using an inverted U- tube.

179 The velocity of flow is given by the equation. Where, C is known as the Pitot tube coefficient (usually 0.95 to 1.0). 4. Elbow meter Pressure differences between the outside and inside walls of an elbow are related to volumetric flow rate. Q = C e KA (P o -P i ) l/2 where, Q = discharge (l/min); C e = elbow meter flow coefficient A = c/s area of elbow (cm 2 ); P o = pressure on outside of elbow ( kPa ); P i = pressure on inside of elbow ( kPa ); k = unit constant(k=8.49)

180

181 5. Co –ordinate method measurements are taken of the jet of water issuing from the end of the pipe and these are used for calculating the rate of discharge.

182 The formula to be used is obtained by combining the following equations : Q = AV………………( i ) Substituting in Eq.( i ) and introducing C, the coefficient of discharge Where, Q = discharge (l/s) X = horizontal distance Y = vertical distance A = area (square centimeter) g = 980 cm/sec 2

183

184 METERS FOR MEASURING CUMULATIVE FLOW Propeller Meters Deathridge Meter Water Meter 1. Propeller Meters record the cumulative flow of water. widely used in USA in the farm irrigation systems at the canal outlets. The flow from the canal outlet is allowed to pass through a pipe into a basin. A propeller which rotates due to the flow of water is installed at the pipe outlet.

185 The number of rotations indicated by a counter will give the cumulative water flow. Calibration and maintenance are important to get accurate readings.

186 Advantages Commercially available Totalizing meter Can achieve good accuracy Disadvantages Operating conditions different from manufacturer’s calibration conditions will affect accuracy Only tolerate small amount of weeds and debris Moving parts operating underwater Can require a good deal of maintenance and inspection

187 used in Australia operates on the same principle as the propeller meter but the construction is different The size of the rotating wheel depends upon the discharges to be measured. The number of rotations are recorded on a counter. The device is to be calibrated in situ to obtain accurate readings. 2. Deathridge Meter

188

189 3. Water Meter designed for measuring pipe flow. generally used for measuring municipal water supplies and are rarely used for measuring water on the farm. These consist of a| multiblade propeller made of metal, plastic or rubber, connected to a counter by means of a gear system. The counter readings are calibrated to give the volumetric flow in the desired units. Water meters are made in different sizes to suit the different pipe diameters and ranges of flow.

190 The basic requirements for using the water meters are : (1) the rate of flow should be within the designed range. (2) The pipe must always flow full. (3) the water should not contain any debris.

191 References R. K. Bansal, A Text Book Of Fluid Mechanics And Hydraulic Machines. P. N. Modi & S. M. Seth, Hydraulics And Fluid Mechanics. K. Subramanya, Engineering Hydrology. V. V. N. Murthy & M. K. Jha, Land And Water Management Engg.. M.G. Boss, Discharge measurement structure.
Tags