620693379-Distribution-Line-Protection-1.pptx

MohamedAbdirizak14 56 views 108 slides Oct 11, 2024
Slide 1
Slide 1 of 108
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53
Slide 54
54
Slide 55
55
Slide 56
56
Slide 57
57
Slide 58
58
Slide 59
59
Slide 60
60
Slide 61
61
Slide 62
62
Slide 63
63
Slide 64
64
Slide 65
65
Slide 66
66
Slide 67
67
Slide 68
68
Slide 69
69
Slide 70
70
Slide 71
71
Slide 72
72
Slide 73
73
Slide 74
74
Slide 75
75
Slide 76
76
Slide 77
77
Slide 78
78
Slide 79
79
Slide 80
80
Slide 81
81
Slide 82
82
Slide 83
83
Slide 84
84
Slide 85
85
Slide 86
86
Slide 87
87
Slide 88
88
Slide 89
89
Slide 90
90
Slide 91
91
Slide 92
92
Slide 93
93
Slide 94
94
Slide 95
95
Slide 96
96
Slide 97
97
Slide 98
98
Slide 99
99
Slide 100
100
Slide 101
101
Slide 102
102
Slide 103
103
Slide 104
104
Slide 105
105
Slide 106
106
Slide 107
107
Slide 108
108

About This Presentation

Distribution line protection


Slide Content

Distribution Line Protection and Maintenance Presented By MD GOLAM MOWLA Executive Engineer( Grid, System Protection and Energy Audit)

Session-1 Mechanical Protection Push Pole Guy wire H-Pole B . Electrical Protection DOFC FUSE MCB ACR/OCR LA CAPACITORBANK Automatic Voltage Regulator

Session-2 Over Current and earth fault Protection connection diagram of O/C & E/F Relay ( 3PO/C+EF) , ( 2P O/C+EF) Under and over voltage protection Directional protection protection of radial Feeder Parallel feeder Ring main system Time graded Over current and earth fault protection Characteristic curve plug setting multiplier time setting multiplier Relay co-ordination 'distribution

Session-3 Transformer Grounding Pole Grounding Equipment Grounding Types of Faults Remedy of Fault Fault current Calculation Fault Clearing time and safety Margin

Session-4 A. Maintenance Procedure Schedule Maintenance Preventive Maintenance . Breakdown or Emergency Maintenance B . Right of way

Session-5 Necessary Testing and Maintenance tools for Line Maintenance Megger (High Insulation Tester ) Earth Tester Clip on Meter Multi meter Chain Block 2 ton Ratchet I ton Conductor cutter Hot Stick Wrench set Insulated pliers Allen key set Tree Trimming Saw Safety belt, Helmet o Safety Gloves etc.

Mechanical Protection of Distribution line Push Pole

Mechanical Protection of Distribution line Guy Wire

Mechanical Protection of Distribution line H-Pole

Mechanical Protection of Distribution line H-Pole

B. Electrical Protection of Distribution line ACR/OCR In  electric power distribution ,  automatic circuit reclosers  ( ACRs ) are a class of  switchgear  which is designed for use on overhead electricity distribution networks to detect and interrupt momentary  faults . Also known as  reclosers  or  autoreclosers , ACRs are essentially  high voltage  rated  circuit breakers  with integrated current and voltage sensors and a  protection relay , optimized for use as an overhead network distribution protection asset. Commercial ACRs are governed by the ANSI/IEEE C37.60, IEC 62271-111 and IEC 62271-200 standards. The three major classes of operating voltage are 15.5 kV, 27 kV and 38 kV.

B. Electrical Protection of Distribution line ACR/OCR

B. Electrical Protection of Distribution line ACR/OCR

B. Electrical Protection of Distribution line ACR/OCR Recloser interrupting mediums Oil interrupters Reclosers using oil for current interruption use the same oil for basic insulation. Some reclosers with hydraulic control also utilize the same oil for timing and counting functions Vacuum interrupters Vacuum interrupters provide fast, low-energy arc interruption with long contact and interrupter life, low mechanical stress, and maximum operating safety. With arc interruption taking place in a vacuum, contact and interrupter life far exceeds other interrupting media. Depending on type, a vacuum recloser may use oil, air, or epoxy as the insulating medium.

Single-phase reclosers  are used to protect single-phase lines such as branches or taps of a three-phase feeder. They can also be used on three-phase circuits where the load is predominantly single-phase. When a permanent phase-to-ground fault occurs, one phase can be locked-out while service is maintained to the remaining two-thirds of the system.  Due to the lighter weight of the single-phase recloser compared to larger three-phase reclosers , single-phase reclosers are typically mounted directly to the pole or substation steel structure individually by the built-in mounting hanger bracket which eliminates the need for an additional mounting frame. Single-phase reclosers can be controlled with a hydraulic control (integrated within the recloser tank), or an electronic control (housed in a separate enclosure) based upon the recloser design.

Automatic Voltage Regulator

Under Voltage Protection(27) Over Voltage Protection(59) What causes over voltages? Power system surges. Due to poor regulation of the power source or power utility company, voltage fluctuations either over or under may occur. ... Insulation Failure. ... Arcing Ground. ... Resonance. ... External causes . Over voltage protection  is a power supply feature which shuts down the supply, or clamps the output, when the voltage exceeds a preset level. Most power supplies use an  over-voltage protection  circuit to prevent damage to the electronic components.

What is Over Voltage Protection(59) Over voltage protection  is a power supply feature which shuts down the supply, or clamps the output, when the voltage exceeds a preset level. Most power supplies use an  over-voltage protection  circuit to prevent damage to the electronic components. What Is  Under voltage ?   Under voltage  conditions are usually be caused by undersized or overloaded utility and facility transformers. During peak demand periods and/or when the utility is experiencing problems, the demand for power exceeds the capability of the transformer and as a result the  voltage  drops .

Under Voltage Protection(27) Over Voltage Protection(59) Under voltage protection  is commonly used to.  protect  motors from damage during abnormal conditions and to prevent breaker-fed motors from re-accelerating after a restoration of bus  voltage Example :-Under Voltage Protection settings Characteristics-Definite time Operation Mode-1/3,2/3,3/3 U1<90% of 11 KVolt T1-5 sec-Alarm U1<85% of 11KV T2=1 sec

Example-Over Voltage Protection(59) Parameter settings of over voltage Characteristics-Definite time Operation Mode-1/3,2/3,3/3 U1>110% of 11 KVolt T1-5 sec-Alarm U1<120 % of 11KV T2=1 sec

Over current and earth fault protection 10/28/2019 56 50/51 I R IY IB IN 50N/51N 50/5 1 IR IY IB IN 50 N /51N

Protection Metering Differential Protection Main Bus Protection Reserve Bus Protection 1S1 1S3 1S2 2S2 2 S1 3 S1 2 S3 3S3 3S2 4S2 4 S1 5 S1 4S3 5S3 5 S2

ANSI TYPE OF PROTECTION APPLICATION VOLTAGE LEVEL 51P OVER CURRENT Line and Transformer(1p,2p,3P),IDMT ALL 51N Earth fault Line and Transformer(1P-E,,PP-E,3P-E)IDMT 50/50N High speed OC/EF Line and Transformer(all O/C and E/F)-DMT 67P/67N Directional OC/EF Line and Transformer(all O/C and E/F 87T Trans.DIFF Transformer(HV-LV,ALL,2 ND Harmonic,5 th harmonic,cross - blocking,over -excitation)DMT 87L Line DIff UG CABLE, Short Dist,Line charging current, 87N REF Star side of TR 87B Bus Differential 25 Synch Check Parallel line & TR 27 Under Voltage Line 59 Over Voltage Line and Transformer 49 Thermal Over Load Line

21 Distance( Zone of protection-z1 to z4,load encroachment, phase selection, Power swing blocking,PUT,POT,DTT,EFCOM,ZCOM,1P-ARC,3P-ARC,67,67N) 79