The electrical installations are classified
according to the classification of voltages as
• Low voltage installation
• Medium voltage installation
• High voltage installation
• Extra High voltage installation
Size: 1.74 MB
Language: en
Added: Jul 27, 2024
Slides: 39 pages
Slide Content
Electrical Design
Classification of Voltages
Standard voltages are classified in NEC as follows
–Low voltage (less than 250 V)
–Medium voltage (250 V to less than 650 V)
–High voltage (650 V to less than 33kV)
–Extra high voltage (33 kV)
The electrical installations are classified
according to the classification of voltages as
•Low voltage installation
•Medium voltage installation
•High voltage installation
•Extra High voltage installation
Standard declared voltages
•240 V ( single phase 2 wire system)
•415 V (three phase 4 wire system)
•3.3kV, 6.6kV, 11kV, 22kV, 33kV, 66kV, 132kV,
220kV, 400kV (line to line voltage)
Voltage limits for AC system
•The voltage at any point of the system under
normal condition shall not depart from the
declared voltage by not more than the below
values
•Low and medium voltages - 6 %
•High voltage - 9 %
•Extra high voltage - 12.5 %
Difference between neutral wire and
earth wire
Classification of supply systems
•T.N. Systems
–In this system 1 point is directly earthed
–The exposed conductive parts of electrical
installations are connected to that point by
protective conductors.
T.N. – S System
•T – direct connection of one point to earth
•N –neutral of ac
•S – neutral and protective functions provided
by separate conductors
•PE – power system earth
T.N.C. – S System
T.N.C.-S system
T.T. system
•T.T. Systems
–The power system has one point directly earthed.
–The exposed conductive parts of the installations
is connected to separate earth electrode which is
electrically independent of the earth electrode of
the power system
I.T. Systems
•No direct connection between live parts and
the earth
•The exposed conductive parts of electrical
installation being directly earthed.
Electric services in buildings
•The nearness of supply point
•Position in the building
•Characteristics of supply (ac or dc)
–Number of phases, voltage levels, power ratings of
equipments and accessories.
•Maximum load demanded/anticipated
•Alternative power supply
•Guidelines of the supply authority are to be followed.
Rating of different luminaries
Number of points for building units
Recommended schedule of socket
outlets
WIRING ACCESSORIES AND ITS
SPECIFICATIONS
Wiring accessories and its
specifications
•AC Energy meter
–Phase : Single, three phase, three phase 4 wire
–Rated voltage: 240 V, 415 V
–Frequency : 50Hz
–Type: Induction type/Electronic
Ceiling fan
•Name of the firm
•Number of blades :
•Size of blade sweep : 36’’, 48’’, 56’’
•Type : AC/DC
•Rated voltage : 240V, single phase
•Frequency : 50 Hz
•Power factor : 0.8 0.9 etc
•Speed : 450 rpm
•Power consumption : 60 W, 100 W etc
•Type of regulator: resistance, eletronic
Tumbler switch
•Rating : 5A
•Control : single/two ways
•Construction material : bakelite with porcelain
base
•Type : surface
•Voltage : 250V
Main Switch: Single phase
•Make : IC (iron clad)
•Rating : 5A/15A/30A/40A/60A etc
•Voltage grade : 250V
•Fuse : one fuse with a neutral link
Main switch (3 phase)
•Make : IC (iron clad)
•No of poles : 3 poles with a neutral link
•Rating : 30A/60A100A/200A/300A
•Voltage grade : 500V
Distribution board (single phase)
•Make : IC (iron clad)
•Ways : two/three/four/five/six
•Ratings : 15A/30A/60A/100A etc
•Voltage grade: 250 V
Distribution board (3 phase)
•Make : IC (iron clad )
•Voltage grade : 500 V
•Bus bars : 3 phase/with or without neutral bus
•No of circuits: two ways to fifteen ways
Fuse carrier
•Fuse carrier : made of porcelain
•Voltage grade: 250V/500V
•Rated current : 15A/30A/60A/100A/200A
Miniature circuit breaker (MCB)
•Voltage rating: 240V/415V AC, 220V DC
•Current rating: 0.5A to 3 A
•No of poles: 1+N, 2,3,3+N,4
•Short circuit
–Breaking capacity: 9 kA
–Rated frequency : 50Hz, 60Hz
–Electrical endurance: more than 50,000 operating cycles
–Mechanical endurance: more than 100,000 operating
cycles
–Permissible ambient temp : 0.5 to +55˚C
–Connection conductor size : 35mm²
Load line Moulded Case Circuit
Breaker (MCCB)
•Voltage rating: 415V AC
•Current rating: 0.5A to 3 A
•No of poles: 2,4
•The load line G frames and A A frames MCCB’s
are available in single pole, three pole and
three pole with switched neutral
Earth leakage circuit breaker
(ELCB)
•Current rating: 25A,40A,63A for 4 pole
• 16A,25A,40A for 2 pole
•Nominal voltage: 240V/415V, 50 Hz
•Short circuit withstand capacity: 6000A
•Sensitivities : 300mA, 100mA,300mA
•Electrical life: 10,000 operations
•Mechanical life : 1 lac operations
•Ambient temperature: -5˚C to +60˚C
•Connecting terminal : 1.5 – 25 mm² condutors
•Protection class : IS – 2147
•Terminations : Flexible upto 25 mm² for 2 poles and 4 poles