Friability test ppt

16,408 views 11 slides Feb 13, 2018
Slide 1
Slide 1 of 11
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11

About This Presentation

Friable: “ A friable substance is any substance that can be reduced to finer particles by the action of a small pressure or friction, such as rubbing or inadvertently brushing up against the substance”.
Friability test: Defined as the % of weight loss by tablets due to mechanical action during ...


Slide Content

TOPIC: FRIABILITY

Hello!
Healthy People...

IPN

Sharing Knowledge

FRIABILITY

Eriable : “ A friable substance is any substance that can be reduced to finer
Particles by the action of a small pressure or friction, such as rubbing or
inadvertently brushing up against the substance”.

Eriability Test : Defined as the % of weight loss by tablets due to mechanical action
duringthe test. Tablets are weighing before & after testing & friability is expressed as
a percentage loss on pre test tablet weight.

& Friability testis done to check the ability ofthe compressed tablet to avoid fracture
& breaking during the transport

FRIABILITY

EA]

ROCHE FRIABILATOR (2)

This testing involves repeatedly dropping a sample of tablets over a fixed
time, using a rotating wheel with a baffle. The result is inspected for
broken tablets, and the percentage of tablet mass lost through chipping.

FRIABILITY

Applicable for compressed uncoated tablets & intended to determine the strength of tablet
during transportation & storage the tablets should retain its shape & size.

Method:

Drum diameter : 283 -29imm

Depth: 36-40mm

Inner radius of the curve projection : 75.5mm - 85,5mm
Outer diameter of the central ring : 24.5mm—25,5mm
Rotation Speed : 25+/_ 1 cycle

Time Set: 4 min

ROCHE FRIABILATOR (2)

To determine the friability

1. ifthe average weight of the tablet is 0.65gm or less Take 10 timesof the whole
weight i.e,6.5gm

2. Carefully deducts thetablets
& weight required numbers oftablets.

Initialweight=6.536gm

3. Setthe Time duration for 4min

4. Set number of countsto 100

5. Make surethedrum iscleanedwithno contaminates,
add the initial weightedtablescarefully & closethe lid

6. Click Start button

Drum diameter : 283 -291mm

Depth: 36-40mm

Inner radius of the curve projection: 75.5mm
—85.5mm

Outer diameter of the central ring: 24.5mm—
25.5mm

Rotation Speed :25+/_1 cycle

Time Set: 4 min

7. After 4min automaticaly it stops,
Take out thetablets & take out the dust from the tablets using brush /crumps

8. Take the After weight of thetablets

Total weight of after rotation=6.443gm

Calculation of friability

Interpretation :

¥ Walueoffriability should not bemorethan 1% for most of tablets.
¥ ifthe value of friability for the first is greater than 1%, then repeat the test twice&
mean ofthreevalues istaken.

Y Ifthe mean value of three tests is less than 1% tablets passes the friability test,

Y otherwisetablet fais thetest.

Ifthe tablets are broken , chipped or cracked during thetest, thetablets fails.
the friability test.



QE,
Pr €

9

O

os
Arcim Bio Clinica

Kir - Better Health... Better Life...