Introduction to High Performance Liquid Chromatography (HPLC)

rajaindian1 68,644 views 37 slides Sep 03, 2014
Slide 1
Slide 1 of 37
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37

About This Presentation

This presentation provides a brief introduction to HPLC and its parts. The technique has found immense scope of applications in both academic and industrial laboratories requiring identification and quantification of mixtures of organic compounds.It is essential for scientists working in any field t...


Slide Content

Introduction to High Performance Liquid Chromatography and its parts 1

Chromatography equipment looks rather intimidating to anyone who has not handled it before, but on a closer look and as you get familiar with the equipment you realize that behind the network of wires, complex plumbing and circuitry is a simple machine with only a few major parts. 2

Different combinations of these parts namely : Pumps Detectors Injectors yield an infinite number of configurations based on the application. 3

Just like an understanding of human anatomy makes you conscious of the vital role of each and every body organ towards your well being and vitality. Similarly you need to have a good understanding of the parts of your HPLC system to generate data of highest reliability. 4

A conceptual understanding of the function of each component will add to your comfort level with your HPLC system. You will ensure long time usage with high reliance on output data. 5

What is HPLC? 6

7

HPLC is a technique for separation, identification and quantification of components in a mixture. It is especially suitable for compounds which are not easily volatalised , thermally unstable and have high molecular weights. 8

Mobile Phase 9

The liquid phase is pumped at a constant rate to the column packed with the stationary phase. Before entering the column the analysis sample is injected into the carrier stream. 10

On reaching the column the sample components are selectively retained  on the basis of physico -chemical interactions between the analyte molecules and the stationary phase. 11

Mobile Phase 12

13

Mobile phase serves to transport the sample to the system. Essential criteria of mobile phase are inertness to the sample components. Pure solvents or buffer combinations are commonly used. The mobile phase should be free of particulate impurities and degassed before use. 14

Mobile Phase Reservoirs 15

16

These are inert containers for mobile phase storage and transport. Generally transparent glass bottles are used so that so as to facilitate visual inspection of mobile phase level inside the container. Stainless steel particulate filters are provided inside for removal of particulate impurities in the mobile phase if any. 17

Pumps 18

19

Variations in flow rates of the mobile phase effect elution time of sample components and result in errors. Pumps provide constant flow of mobile phase to the column under constant pressure. 20

Injectors 21

22

Injectors are used to provide constant volume injection of sample into the mobile phase stream. Inertness and reproducibility of injection are necessary to maintain high level of accuracy. 23

Column 24

25

A column is a stainless steel tube packed with stationary phase. It is a vital component and should be maintained properly as per supplier instructions for getting reproducibility and separation efficiency run after run. 26

Column Oven 27

28

Variation of temperature during the analytical run can result in changes of retention time of the separated eluting components. A column oven maintains constant column temperature using air circulation. This ensures a constant flow rate of the mobile phase through the column 29

Detector 30

31

A detector gives specific response for the components separated by the column and also provides the required sensitivity. It has to be independent of any changes in mobile phase composition. Majority of the applications require UV-VIS detection though detectors based on other detection technique are also popular these days. 32

Data Acquisition & Control 33

Modern HPLC systems are computer based and software controls operational parameters such as mobile phase composition, temperature, flow rate, injection volume and sequence and also acquisition and treatment of output. 34

Specialized Versions 35

Specialized HPLC Systems might also have solvent selection valves, vacuum degasser, auto samplers, column switches, pre or post column  derivatization and fraction collectors. These are all covered at length in our online certificate program on HPLC. Certificate Course on HPLC 36

What Next? Keep Learning to Keep Succeeding – visit www.lab-training.com/hplc to learn more about HPLC Get online certificate training on HPLC – www.lab-training.com/product/join-our-certificate-course-on-hplc/ Subscribe to our newsletter and get free training delivered straight to your inbox – www.lab-training.com Don’t have a HPLC? Need samples to be tested visit www.testing-lab.com and get a proposal! 37