Piping & Instrument Diagram

pankkaj 5,019 views 21 slides Jul 04, 2015
Slide 1
Slide 1 of 21
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21

About This Presentation

P & I Diagram is an engineering drawing


Slide Content

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
M
Reactant ‘A’
PID-1 FA
From 01P001A/B 25NB
Drain
XV
0301
80-FA-03-01-XA1
I
03.1
80-FA-01-12-XA1
N1 N4 N5
50NB
50NB
50NB
N8
LT
0301
25NB
Drain
LI
0301
LAL
0301
LAH
0301
LSH
0301
I
03.1
N7
80NB
N6
Reactant ‘A’
PID-1 FA
To 01T001
N2
N3
25NB
Drain
25NB
Drain
XV
0302
50-FB-03-06-XB1
I
03.3
Reactant ‘B’
PID-2 FB
From 02P001A/B
50-FB-02-21-XB1
N8
LT
0302
25NB
Drain
LI
0302
LAL
0302
LAH
0302
LSH
0302
I
03.3
80NB
Reactant ‘A’
PID-4 FA
To 03R001B/C/D
25NB
Drain
FCV
0301
50-FA-03-03-XA1
FT
0301
FIC
0301
FAH
0301
FAL
0301
FY
0301
I
03.2
CR50X25CR50X25
CR50X40
CR50X40
25
-
FA
-
03
-
12
-
XA1
100-FA-03-09-XA1
50-FA-03-02-XA1
Waste Gases
PID-9 FG
To 05C001
100-FG-03-10-XG1
Process Water
PID-8 PW
From 08P002A/B
40-PW-12-15-XP1
25
-
PW
-
03
-
08
-
XP1
N1
N2
N7
N6
N4
N5
Cooling Water
PID-7 CW
From 07P001A/B
N10
50-CW-10-17-XC1
N9
Cooling Water
PID-7 CW
To 07U001
15NB
Vent
TI
0302
TE
0302
CR80X50
CR80X50
50-CW-03-07-XC1
Product Slurry
PID-4 FP
To 04T001
N3
Hose
25NB
100-FP-03-11-FP1
TI
0301
TE
0301
TW1
TAL
0301
TAH
0301
TSHH
0301
I
03.2
EL +19.300M
EL + 6.300M
03T001
03R001A
03R001AN01
50NB
50
-
FA
-
03
-
05
-
XA1
50
-
FA
-
03
-
04
-
XA1

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Symbolic Representation
for Communication

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Symbolic Representation

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Symbolic Representation

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Symbolic Representation

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Symbolic Representation

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Symbolic Representation

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Legend List

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Symbolic Representation

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Symbolic Representation
•Equipment
•Piping
•Instrument
•Electrical
•Structure
•Civil
•Equipment
•Piping
•Instrument

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Chemistry
A + B P + G+ Heat
Block Diagram

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Block Diagram
Reaction
Cooling
Filtration Drying
Distillation
Filtrate
Wet
Cake
Pulverizing
Dried
Cake
Product
‘P’
Water
G
To ETP
‘B’
‘A’
Scrubbing
Water
Waste
‘P’
+
‘A’
‘W’ + ‘A’
‘W’
A + B = P + G + Heat

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Block Diagram
Reaction
Cooling
Filtration Drying
Distillation
Filtrate
Wet
Cake
Pulverizing
Dried
Cake
Product
‘P’
Water
G
To ETP
‘B’
‘A’
Scrubbing
Water
Waste
‘P’
+
‘A’
‘W’ + ‘A’
‘W’
A + B = P + G + Heat
Flow Sheet

M
01T001 02T001 04T00101P001A/B 02P001A/B 04P001A/B
03T001
03R001A/B/C/D
CWR
CWS
Slurry
To Filter
Reactant ‘B’
From Bulk Storage
Reactant ‘A’
From Bulk Storage
Recovered ‘A’
From Recovery
[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Flow Sheet

M
01T001 02T001 04T00101P001A/B 02P001A/B 04P001A/B
03T001
03R001A/B/C/D
CWR
CWS
Slurry
To Filter
Reactant ‘B’
From Bulk Storage
Reactant ‘A’
From Bulk Storage
Recovered ‘A’
From Recovery
[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Flow Sheet
P & I D

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
P & I D
T-201 P-201 A P-201 B
W EF1
W EF1
W EF1
N
1
N
2
N
3
N
4 N
5
N
6
100 NB
From P-101 A/B
To T-301
L1006-100-FA-XA1
PID-1
PID-6
L2001-100-FA-XA1
L2002-100-FA-XA1
L2003-80-FA-XA1
L2004-80-FA-XA1
ER100x80 ER100x80
CR80x65 CR80x65
PW PW
N
7
D
SP
PI
201B
PI
201A
LI
201
50 NB
FT
201
L2005-80-FA-XA1
FCV
201
FIC
201
FAH
201
FAL
201
FSHH
201
I.1
I.1
I.1
L2006-65-FA-XA1

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Liquid Storage P & I D
T-201 P-201 A P-201 B
W EF1
W EF1
W EF1
N
1
N
2
N
3
N
4 N
5
N
6
100 NB
From P-101 A/B
To T-301
L1006-100-FA-XA1
PID-1
PID-6
L2001-100-FA-XA1
L2002-100-FA-XA1
L2003-80-FA-XA1
L2004-80-FA-XA1
ER100x80 ER100x80
CR80x65 CR80x65
PW PW
N
7
D
SP
PI
201B
PI
201A
LI
201
50 NB
FT
201
L2005-80-FA-XA1
FCV
201
FIC
201
FAH
201
FAL
201
FSHH
201
I.1
I.1
I.1
L2006-65-FA-XA1

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
T-201 P-201 A P-201 B
W EF1
W EF1
W EF1
N
1
N
2
N
3
N
4 N
5
N
6
100 NB
From P-101 A/B
To T-301
L1006-100-FA-XA1
PID-1
PID-6
L2001-100-FA-XA1
L2002-100-FA-XA1
L2003-80-FA-XA1
L2004-80-FA-XA1
ER100x80 ER100x80
CR80x65 CR80x65
PW PW
N
7
D
SP
PI
201B
PI
201A
LI
201
50 NB
FT
201
L2005-80-FA-XA1
FCV
201
FIC
201
FAH
201
FAL
201
FSHH
201
I.1
I.1
I.1
L2006-65-FA-XA1
Details Included
Identification Numbers for
•Equipment (T-201)
•Pipeline (L2001-100-FA-XA1)
•Instrument (PI-201A)
•Special Parts (PSV, RO)

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
T-201 P-201 A P-201 B
W EF1
W EF1
W EF1
N
1
N
2
N
3
N
4 N
5
N
6
100 NB
From P-101 A/B
To T-301
L1006-100-FA-XA1
PID-1
PID-6
L2001-100-FA-XA1
L2002-100-FA-XA1
L2003-80-FA-XA1
L2004-80-FA-XA1
ER100x80 ER100x80
CR80x65 CR80x65
PW PW
N
7
D
SP
PI
201B
PI
201A
LI
201
50 NB
FT
201
L2005-80-FA-XA1
FCV
201
FIC
201
FAH
201
FAL
201
FSHH
201
I.1
I.1
I.1
L2006-65-FA-XA1
Details Included
Critical Details
•Minimum Distance
•Elevation
•Slope

[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
T-201 P-201 A P-201 B
W EF1
W EF1
W EF1
N
1
N
2
N
3
N
4 N
5
N
6
100 NB
From P-101 A/B
To T-301
L1006-100-FA-XA1
PID-1
PID-6
L2001-100-FA-XA1
L2002-100-FA-XA1
L2003-80-FA-XA1
L2004-80-FA-XA1
ER100x80 ER100x80
CR80x65 CR80x65
PW PW
N
7
D
SP
PI
201B
PI
201A
LI
201
50 NB
FT
201
L2005-80-FA-XA1
FCV
201
FIC
201
FAH
201
FAL
201
FSHH
201
I.1
I.1
I.1
L2006-65-FA-XA1
Details Included
Others
•Battery Limit
•Pipe Class Break
•Special Notes

M
Reactant ‘A’
PID-1 FA
From 01P001A/B 25NB
Drain
XV
0301
80-FA-03-01-
XA1
I
03.1
80-FA-01-12-
XA1
N1 N4 N5
50NB50NB
50NB
N8
LT
0301
25NB
Drain
LI
0301
LAL
0301
LAH
0301
LSH
0301
I
03.1
N7
80NB
N6
Reactant ‘A’
PID-1 FA
To 01T001
N2
N3
25NB
Drain
25NB
Drain
XV
0302
50-FB-03-06-
XB1
I
03.3
Reactant ‘B’
PID-2 FB
From 02P001A/B
50-FB-02-21-
XB1
N8
LT
0302
25NB
Drain
LI
0302
LAL
0302
LAH
0302
LSH
0302
I
03.3
80NB
Reactant ‘A’
PID-4 FA
To 03R001B/C/D
25NB
Drain
FCV
0301
50-FA-03-03-
XA1
FT
0301
FIC
0301
FAH
0301
FAL
0301
FY
0301
I
03.2
CR50X25CR50X25
CR50X40
CR50X40
25
-
FA
-
03
-
12
-
XA1
100-FA-03-09-
XA1
50-FA-03-02-
XA1
Waste Gases
PID-9 FG
To 05C001
100-FG-03-10-
XG1
Process Water
PID-8 PW
From 08P002A/B
40-PW-12-15-XP1
25
-
PW
-
03
-
08
-
XP1
N1
N2
N7
N6
N4
N5
Cooling Water
PID-7 CW
From 07P001A/B
N10
50-CW-10-17-XC1
N9
Cooling Water
PID-7 CW
To 07U001
15NB
Vent
TI
0302
TE
0302
CR80X50
CR80X50
50-CW-03-07-
XC1
Product Slurry
PID-4 FP
To 04T001
N3
Hose
25NB
100-FP-03-11-
FP1
TI
0301
TE
0301
TW1
TAL
0301
TAH
0301
TSHH
0301
I
03.2
EL +19.300M
EL + 6.300M
03T001
03R001A
03R001AN01
50NB
50
-
FA
-
03
-
05
-
XA1
50
-
FA
-
03
-
04
-
XA1
Rev.
No.
0
PROJECT
05001
DRAWING NUMBER
PID –05001 –01 -101
P & I Drawing
For Reaction System
Code No.
03T001
03R001A
03R001AN01
Description
Reactant ‘A’ Overhead Tank
Reactor
Agitator for Reactor 03R001A
R Description Drn Chkd Appd Dt.
Client : M/s ABC Co.
Plant : 30 TPD of Product ‘P’
Location : Pune (Maharashtra)
Notes:
1)
2)
3)
[email protected]
Building up Confidence
Koncept Learning Center
P & I Diagram
Tags