Reinforced column design

Azeemiqrah 80,737 views 42 slides Dec 30, 2015
Slide 1
Slide 1 of 42
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42

About This Presentation

Reinforced concrete column design according to bs 8110


Slide Content

Reinforced concrete column Prepared by: M.N.M Azeem Iqrah B.Sc.Eng ( Hons ), C&G ( Gdip ) Skills College of Technology

Introduction to column Columns act as vertical supports to beams and slabs, and to transmit the loads to the foundations. Columns are primarily compression members, although they may also have to resist bending moment transmitted by beams. Columns may be classified as short or slender, braced or unbraced depending on various dimensional and structural factors.

Column sections Common column cross sections are: (a) square, (b) circular and (c) rectangular section. The greatest dimension should not exceed four times its smaller dimension. (h≤4b). For h>4b, the member should be regarded as a wall for design purpose.

Failure modes of columns Columns may fail in one of three mechanisms: Compression failure of the concrete or steel reinforcement; Buckling Combination of buckling and compression failure. Compression failure is likely to occur with columns which are short and stocky. Buckling is probable with columns which are long and slender.

Failure modes of columns Comp r ession failure Buckling

Short and slender columns (Clause 3.8.1.3, BS 8110) A braced column is classified as being short if :

Braced and unbraced columns (clause 3.8.1.5, BS 8110) A column may be considered braced in a given plane if lateral stability to the structure as a whole is provided by wall or bracing or buttressing designed to resist all lateral forces in that plane. It should otherwise be considered as unbraced.

Braced and unbraced columns (clause 3.8.1.5, BS 8110)

Braced and unbraced columns (clause 3.8.1.5, BS 8110)

Effective height of column (clause 3.8.1.6, BS 8110) The effective height, le of a column in a given plane may be obtained from the following equation: Where  is a coefficient depending on the fixity at the column ends and lo is the height of the columns. Effective height for a column in two plane directions may be different.

Effective height of column (clause 3.8.1.6, BS 8110)  for braced column can be obtained from Table 3.19. End condition 1 signifies that the column end is fully restrained. End condition 2 signifies that the column end is partially restrained . End condition 3 signifies that the column is nominally restrained.

End conditions (clause 3.8.1.6.2, BS 8110) End condition 1 – the end of the column is connected monolithically to beams on either side which are at least as deep as the overall dimension of the column in the plane considered. Where the column is connected to foundation, it should be designed to carry moment.

End condition 2 – the end of column is connected monolithically to beams or slabs on either side which are shallower than the overall dimension of the column in the plane considered. End conditions (clause 3.8.1.6.2, BS 8110)

End condition 3 – the end of the column is connected to members which, while not specifically designed to provide restraint to rotation of the column will nevertheless, provide some nominal restraint. End conditions (clause 3.8.1.6.2, BS 8110)

Example 3.17 classification of column (Arya, 2009) Determine if the column shown below is short.

Example 3.17 classification of column (Arya, 2009)

Short column design The short column are divided into three categories: Columns resisting axial load only, Columns supporting an approximately symmetrical arrangement of beams, Columns resisting axial loads and uniaxial or biaxial bending

B2 will resist an axial load only, as it supports beams equal in length and symmetrically arranged.

C2 supports a symmetrical arrangement of beams but which are unequal in length. If (a) the loadings on the beam are uniformly distributed, (2) the beam spans do not differ by more than 15 percent, the column C2 belongs to category 2. If the column does not meet criteria (a) and (b), then the column belongs to category 3.

Theoretical strength of reinforced concrete column The equation is derived on the assumption that the axial load is applied perfectly at the centre of the column.

Clause 3.8.4.3 Nominal eccentricity of short columns resisting moments and axial force To allow for nominal eccentricity, BS 8110 reduce the theoretical axial load capacity by about 10%. Design maximum axial load capacity of short column is:

Clause 3.8.4.4 Short braced columns supporting an approximately symmetrical arrangement of beam The column is subjected to axial and small moment when it supports approximately symmetrical arrangement of beams: • The design axial load capacity:

Column resisting an axial load and uniaxial bending For column resisting axial load and bending moment at one direction, the area of longitudinal reinforcement is calculated using design charts in Part 3 BS 8110. The design charts are available for columns having a rectangular cross section and symmetrical arrangement of reinforcement.

Column resisting an axial load and uniaxial bending Design charts are derived based on yield stress of 460 N/mm 2 for reinforcement steel. They are applicable for reinforcement with yield stress of 500 N/mm 2 , but the area of reinforcement obtained will be approximately 10% greater than required. Design charts are available for concrete grades – 25, 30, 35, 40, 45 and 50. The d/h ratios are in the range of 0.75 to 0.95 in 0.05 increment.

Design chart for column resisting an axial load and uniaxial bending moment, (Part 3, BS 8110)

Column resisting an axial load and biaxial bending The columns are subjected to an axial and bending moment in both x and y directions. The columns with biaxial moments are simplified into the columns with uniaxial moment by increasing the moment about one of the axes then design the reinforcement according the increased moment.

Column resisting an axial load and biaxial bending (clause 3.8.4.5, BS 8110)

Reinforcement details: longitudinal reinforcement (clause 3.12.5, BS 8110) Size and minimum number of bars – bar size should not be less than 12 mm in diameter. Rectangular column should reinforced with minimum 4 bars; circular column should reinforced with minimum 6 bars. The area of longitudinal reinforcement should lie in the limits: 3. Spacing of reinforcement – the minimum distance between adjacent bars should not be less than the diameter of the bar or hagg + 5 mm.

Reinforcement details – links (clause 3.12.7, BS 8110) The axial loading on the column may cause buckling of the longitudinal reinforcement and subsequent cracking and spalling of concrete cover. Links are passing round the bars to prevent buckling.

Reinforcement details – links (clause 3.12.7, BS 8110) Size and spacing of links – the diameter of the link should be at least one quarter of the largest longitudinal bar size or minimum 8 mm. The maximum spacing is 12 times of the smallest longitudinal bar. Arrangement of links

Example 3.20 axially loaded column (Arya, 2009) Design the longitudinal and links for a 350mm square, short braced column based on following information.

Example 3.20 axially loaded column (Arya, 2009)

Example 3.21 Column supporting an approximately symmetrical arrangement of beam ( Arya, 2009) An internal column in a braced two-storey building supporting an approximately symmetrical arrangement of beams (350mm wide x 600 mm deep) results in characteristic dead and imposed loads each of 1100 kN being applied to the column. The column is 350 mm square and has a clear height of 4.5 m. Design the longitudinal reinforcement and links.

Example 3.21 Column supporting an approximately symmetrical arrangement of beam ( Arya, 2009)

Example 3.21 Column supporting an approximately symmetrical arrangement of beam ( Arya, 2009)

Example 3.21 Column supporting an approximately symmetrical arrangement of beam ( Arya, 2009) Links  link = diameter of largest longitudinal bar/4 = 32/4 = 8 mm (equal to minimum bar size of 8 mm) The spacing of the links = the lesser of (12 smallest longitudinal bar or the smallest cross sectional dimension of column) = the lesser of (12x25 = 300 mm or 350 mm) = 300 mm

Example 3.22 Columns resisting an axial load and bending moment Design the longitudinal and shear reinforcement for a 275 mm square, short braced column which supports either (a) An ultimate axial load of 1280 kN and a moment of 62.5 kNm about the x-x axis (b) An ultimate axial load of 1280 kN and bending moment of 35 kNm about the x-x axis and 25 kNm about the y-y axis

Example 3.22 Columns resisting an axial load and bending moment

Example 3.22 Columns resisting an axial load and bending moment

Example 3.22 Columns resisting an axial load and bending moment

Example 3.22 Columns resisting an axial load and bending moment

Example 3.22 Columns resisting an axial load and bending moment