Slide Content

Viscosity Measurement Rotation Viscometer

VISCOSITY A fluid flow property. Internal property of a fluid that offers resistance to flow. It is a measure of how easily a fluid can flow. It can also be viewed as viscosity is a resistance to shear force Formula : Viscosity   Introduction

There are two types of Viscosity: 1. Dynamic/Absolute Viscosity ( Units: 1 Pa.s = 1 kg/(m.s) = 1 N.s/ 1 Poise = 100 cP = 0.1 Pa.s 2. Kinetic Viscosity ( : Units: 1 stoke = 1 /s = 0.0001 /s Relation between Dynamic and Kinetic viscosity :  

Newtons law of Viscosity : Newton’s law of Viscosity states that, the shear stress between adjacent fluid layers is proportional to the velocity gradients between the two layers.   Where , = Shear stress = = Dynamic Viscosity = Rate of Shear strain Shear strain  

Methods of Viscosity Measurement Viscometers A Viscometer is an instrument used to measure the viscosity of a fluid. It is also known as Viscosimeter. Viscometers only measures under one flow condition. Based on working principle, viscometers are divided into three categories: Drag experienced by a falling ball through a fluid ( Falling ball viscometer ) Drag experienced by one of the concentric cylinders carrying fluid between them when the other cylinder is rotating ( Rotating concentric cylinder viscometer ) Flow through a capillary tube ( Capillary tube viscometer, Ostwald viscometer )

Rotating Viscometers These viscometers are suitable for both Newtonian and non-Newtonian systems. Amongst the most widely used viscometer Very simple construction

Eg. MacMicheal viscometer Searle type viscometer (Upper cylinder rotates) Couette type viscometer (Lower cylinder rotates) Eg. Brookfield viscometer Rotation Viscometer Eg. Stormer viscometer Types :

Construction Lower cylinder (cup) revolving Upper cylinder (bob) Liquid under test Pulley Torsion wire Scale and pointer Lower cylinder revolving at constant angular velocity. To get constant angular velocity, motor is connected to pulley

Working Principle: Newton’s law is the basis of the Rotating viscometer. Based on the principle that the fluid whose viscosity is being measured is sheared between two surfaces. In these viscometer one of the surface is stationary and other is rotated by an external drive and fluid fills the space in between. The measurements are conducted by Appling either a constant torque and measuring the changes in the speed of rotation or applying a constant speed and measuring the changes in the torque.

Initially, Lower cylinder rotates at and upper cylinder rotates at . After some time, torsion wire get rotated by and angular velocity of upper cylinder becomes zero. At equilibrium condition, torque due to sheared liquid and due to torsion wire will be equal. No slip condition will be obtained at the equilibrium. Equating both torque, we get coefficient of viscocity .  

Derivation Velocity gradient = Here angular velocity gradient = Considering any layer at distance x from centre line, Force on second layer due first layer is given by, Where , – coefficient of viscosity A – area of cylindrical layer (negative due to sig Now , torque is given by = Therefore , Integratinng from x=R2 (bob), =0 to x=R1 (cup) , = O  

Finally, we get For torsion string, = c = (torsional rigidity) (angle rotated) Equating both torque , we get value of coefficient of viscosity. Final equation can be reduced to the form η= K/w Where , K - instrument constant  

Advantages : Can measure viscosities of opaque, settling, or non-Newtonian fluids. Useful for characterizing shear- thinning and time dependent behavior. Speed of the rotating part easily adjusted. Often linked to computers for semiautomated measurement. Disadvantages : Can be relatively expensive. Often large and not portable.