Summary of NBC 2016

2,021 views 189 slides Dec 20, 2023
Slide 1
Slide 1 of 189
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53
Slide 54
54
Slide 55
55
Slide 56
56
Slide 57
57
Slide 58
58
Slide 59
59
Slide 60
60
Slide 61
61
Slide 62
62
Slide 63
63
Slide 64
64
Slide 65
65
Slide 66
66
Slide 67
67
Slide 68
68
Slide 69
69
Slide 70
70
Slide 71
71
Slide 72
72
Slide 73
73
Slide 74
74
Slide 75
75
Slide 76
76
Slide 77
77
Slide 78
78
Slide 79
79
Slide 80
80
Slide 81
81
Slide 82
82
Slide 83
83
Slide 84
84
Slide 85
85
Slide 86
86
Slide 87
87
Slide 88
88
Slide 89
89
Slide 90
90
Slide 91
91
Slide 92
92
Slide 93
93
Slide 94
94
Slide 95
95
Slide 96
96
Slide 97
97
Slide 98
98
Slide 99
99
Slide 100
100
Slide 101
101
Slide 102
102
Slide 103
103
Slide 104
104
Slide 105
105
Slide 106
106
Slide 107
107
Slide 108
108
Slide 109
109
Slide 110
110
Slide 111
111
Slide 112
112
Slide 113
113
Slide 114
114
Slide 115
115
Slide 116
116
Slide 117
117
Slide 118
118
Slide 119
119
Slide 120
120
Slide 121
121
Slide 122
122
Slide 123
123
Slide 124
124
Slide 125
125
Slide 126
126
Slide 127
127
Slide 128
128
Slide 129
129
Slide 130
130
Slide 131
131
Slide 132
132
Slide 133
133
Slide 134
134
Slide 135
135
Slide 136
136
Slide 137
137
Slide 138
138
Slide 139
139
Slide 140
140
Slide 141
141
Slide 142
142
Slide 143
143
Slide 144
144
Slide 145
145
Slide 146
146
Slide 147
147
Slide 148
148
Slide 149
149
Slide 150
150
Slide 151
151
Slide 152
152
Slide 153
153
Slide 154
154
Slide 155
155
Slide 156
156
Slide 157
157
Slide 158
158
Slide 159
159
Slide 160
160
Slide 161
161
Slide 162
162
Slide 163
163
Slide 164
164
Slide 165
165
Slide 166
166
Slide 167
167
Slide 168
168
Slide 169
169
Slide 170
170
Slide 171
171
Slide 172
172
Slide 173
173
Slide 174
174
Slide 175
175
Slide 176
176
Slide 177
177
Slide 178
178
Slide 179
179
Slide 180
180
Slide 181
181
Slide 182
182
Slide 183
183
Slide 184
184
Slide 185
185
Slide 186
186
Slide 187
187
Slide 188
188
Slide 189
189

About This Presentation

Presentation on NBC 2016


Slide Content

NATIONAL BUILDING CODE
OF INDIA 2016:
ANOVERVIEW
S. ArunKumar
Scientist ‘E’ (Civil Engg)
Bureau of Indian Standards
1

2

3

4

2030
5

NEED FOR BUILDING REGULATION AND
CONSTITUTIONAL POSITION
SubjectsrelatingtolandandbuildingsfallundertheStateList
(SeventhSchedule)
35.Works,landsandbuildingsvestedinorinthepossessionofthe
State.
49.Taxesonlandsandbuildings.
Schedule(referredtounderArticle243W)addedbythe
Constitution(74thAmendment)Act,1992(w.e.f01.06.1993),
1. Urban planningincluding town planning.
2. Regulation of land-use and construction of buildings.
3. Planning for economic and social development.
4. Roads and bridges.
5. Water supplyfor domestic, industrial and commercial purposes.
6. Public health, sanitation conservancy and solid waste
management.
7. Fire services.
6

8. Urban forestry, protection of the environment and promotion of
ecological aspects.
9. Safeguarding the interests of weaker sections of society, including
the handicapped and mentally retarded.
10. Slum improvementand upgradation.
11. Urban poverty alleviation.
12. Provision of urban amenities and facilities such as parks,
gardens, playgrounds.
13. Promotion of cultural, educational and aesthetic aspects.
14. Burials and burial grounds; cremations, cremation grounds; and
electric crematoriums.
15. Cattle ponds; prevention of cruelty to animals.
16. Vital statistics including registration of births and deaths.
17. Public amenities including street lighting, parking lots, bus stops
and public conveniences.
18. Regulation of slaughter houses and tanneries.
7
NEED FOR BUILDING REGULATION AND
CONSTITUTIONAL POSITION

AUTHORITIES HAVING JURISDICTION
1)MunicipalCorporation
2)Municipality
3)NotifiedAreaCommittee
4)TownAreaCommittee
5)CantonmentBoard
6)Township
7)PortTrust
8)SpecialPurposeAgencylike:
Town improvement trusts.
Urban development authorities.
Water supply and sewerage boards.
Housing boards.
Pollution control boards.
Electricity supply boards.
City transport boards.
8

9
Source: http://lgdirectory.gov.in/
ENTITIES UNDER THE LAND REGIONS/REVENUE,
RURAL AND URBAN LOCAL GOVERNMENTS

INSTRUMENTS FOR BUILDING
REGULATION
Town and Country Planning Act/
Development Act
Master Plan, Zonal Plans and Layout Plans
Municipality/Municipal Corporation Act
Building Bye-Laws
1
0

11
AUTHORITIES ADDITIONAL CLEARANCES
Fire Authorities High rise and special
(fire vulnerable) buildings
Chief Inspectorate of Factories Industrial buildings
Pollution Control Board Asper respective state norms
Chief Controller of Explosives,
Nagpur
Hazardous buildings
Urban Art Commission As per relevant Acts
Archaeological Survey of IndiaPlot falling within 300 m distance
from any protected monument
Railway/Metro-rail Authority Plot is falling within railway corridor
Airports Authority of India Plot is falling in proximity of airport;
etc
AUTHORITIES FOR ADDITIONAL
CLEARANCES THAT MAY BE REQUIRED

12

13
HISTORICAL
Year History
1965 Panel of Experts appointed by Planning Commission to study the whole
gamut of operations involved in construction such as:
Administrative, Organizational, Financial, Technical
1968 ‘Report on Economies in Construction Costs’ recommended:
•One of the important steps towards achieving economy is through
formulation of Unified Building Codeat national level.
•For this NBC to be brought out unifying building regulations throughout the
country
•Job entrusted to the then ISI (now BIS)
1970 NBC (first version)
1983 NBC (first revision)
1987 Amendment No. 1 & 2 to NBC 1983
1997 Amendment No. 3 to NBC 1983
2005 NBC (second revision)
2015 Amendment No. 1 & 2 to NBC 2005
2016 NBC (third revision)

Salient Features of NBC 2016
14
•Dealt by National Building Code Sectional Committee,
CED 46 of BIS
•Revision of the Code initiated in 2014
•22 Expert Panels involved in which around 1000 experts
contributed
•Around 50 Meetings of the Experts Panels were organized
•Involves stakeholder engagement and wide consultation
process
•Revised Code is a culmination of the untiring efforts of
above Experts and BIS
•A voluminous document published in two volumes

Salient Features of NBC 2016
•Substantial improvementsincorporated, particularly for
Ensuring structurally safe and disaster resistant
buildings
Accessibilityof buildings and built environment for
persons with disabilities and the elderly
Fire safety of modern complex and high-rise buildings
Use of new/innovativebuilding materials and technologies
Ensuring speedier construction through prefab
technology
Installation of modern plumbingand building services
Ensuring IT enabled buildings
Sustainabilityand conducive outdoor built environment
Managementof constructed building assets and facilities

Salient Features of NBC 2016
16
•Expected to be extensively used by,
thelocalbodiesforframingandrevampingtheexisting
localbuildingbyelaws
theGovt.andprivateconstructionagenciesintheir
constructionactivities
thebuildingprofessionalslikearchitects,engineers,
structuralengineers,townplanners,buildingservices
engineersandconsultantsinthedesignofbuildingand
builtenvironment
buildingmaterialsuppliersandtechnologyproviders
researchinstitutionsfortheirresearchpurposes
facultyandstudentsofacademicinstitutionsfor
impartingtechnicaleducationtoarchitecturaland
engineeringstudentsbyusingtheCodeaspartoftheir
curriculum

4 Pillars of Safety
Structural Safety
Health Safety
Fire Safety
Public Safety
17

CONTENTSOF NBC 2016
18
Part No. Title
Part 0 Integrated Approach –Prerequisite for Applying Provisions of the code
Part 1 Definitions
Part 2 Administration
Part 3 Development Control Rules and General Building Requirements
Part 4 Fire and Life Safety
Part 5 Building Materials
Part 6 Structural Design
Part 7 Constructional Management, Practices and Safety
Part 8 Building Services
Part 9 Plumbing Services (including Solid Waste Management)
Part 10 Landscape Development, Signs and Outdoor Display Structures
Part 11 Approach to Sustainability
Part 12 Asset and Facility Management

19

20

PART 0
INTEGRATED APPROACH –PREREQUISITE
FOR APPLYING PROVISIONS OF THE
CODE
21

TEAM APPROACH
Sl. NoMajor Stages Corresponding Team
Purpose
1.
Location/siting
Design team
Proper integration of
various design inputs
Conceptualization &
planning
Designing and
detailing
2.
Construction/
execution
Project Management &
Construction
Management Teams
Accomplishment in
accordance with
designs and
specifications in a
stipulated time and cost
framework.
3.
Maintenance and
repair
Operation &
Maintenance Team or
Asset Management
Team or
Estate Management
Team
Operation, maintenance
and repairs to be
executed with least
inconvenience and
without any mismatch/
damage to structure,
finishings, fittings, etc.
22

MULTI DISCIPLINARY TEAM OF BUILDING
PROFESSIONALS
23Each team to be multi-disciplinary team of need based professionals,
depending upon type, size, magnitude, complexity in the project; such as:
Architect
Civil Engineer
Structural Engineer
Geotechnical Engineer
Electrical Engineer
Plumbing Engineer
Fire Protection Engineer
HVAC Engineer
Lift, Escalator & Moving Walk
Specialist
Acoustics Specialist
Information/Communication
Technology Engineer
Health, Safety & Environment
Specialist
Environment/Sustainability
Specialist
Town Planner
Urban Designer
Landscape Architect
Security System Specialist
Interior Designer
Quantity Surveyor
Project/Construction Manager
Accessibility & Universal
Design specialist
Asset/Facility Manager
Other subject specialists

Major Modifications inPart 1 -Definitions
VariousnewtermsaddedinvariousChaptersduring
thisrevisionoftheCodearereflectedinthisPart.
Manyoftheexistingdefinitionshavebeenmodified
basedoninternationallyaccepteddefinitions.
24

PART 1
DEFINITIONS
Lists the terms which are appearing in all the
Parts/Sections of the National Building Code of India,
along with their definitions.
Terms arranged in alphabetical order.
The Part(s)/Section(s) in which these terms are appearing, have
been indicated against the terms.
However, some common definitions are reproduced in
this Part also, the definitions being placed immediately
below the term concerned.
25

STRUCTURED APPROACH FOR ENSURING
COMPLIANCE TO PROVISIONS OF
NBC 2016 IN THE CODE
Stages in Building Permit Process
1. Submission of application by owner along with
-Building plan
-Service plan
-Specifications
-Structural design sufficiency certificateby engineer/
structural engineer and owner
-Certificate of engagement of builder/constructor(s)
-Certificate of supervisionby architect/engineer
2. Verification of building plans and specifications by the
Authority with respect to building byelaws
26

STRUCTURED APPROACH FOR ENSURING
COMPLIANCE TO PROVISIONS OF
NBC 2016 IN THE CODE….
3.Sanction by the Authority including approvals from
statutory authorities
-Two stage approval for vulnerable buildings
4. Construction activity
5.Step-wise inspection by local authority
6. Completion of construction activity
7. Notice of completion by owner along with
-Certification for execution of workas per structural
safety requirements by engineer/ structural engineer
8.Inspection by Authority
9.Issue of Occupancy Permit by Authority.
27

PART 2
ADMINISTRATION
It covers the administrative aspects of the
Code, such as applicability of the Code,
organization of building department for
enforcement of the Code, procedure for
obtaining development and building
permits, and responsibility of the owner
and all professionals involved in the
planning, design and construction of the
building.
28

29

PART 2
ADMINISTRATION Contd…
Organization of Building Department for enforcement of the
Code
Qualifications & competence of registered professionals
(Annex A)
Responsibilities of owner and professionals involved
TwelveStandard Forms
Form for first application to develop, erect, re-erect or to make
alteration in any place in a building
Form for certificate for structural design sufficiency
Form for engagementof builder/constructor
Form for supervision
Form for sanction or refusal of development/building permit
Form for notice for commencement
Form for certificate for sub-surface investigation
Form for certificate for completed structural design work as per
structural safety requirements
Form for certificate for supervisionof execution of work
Form for certificate for completed work by builder/constructor
Form for completion certificate
30

Major Modifications inPart 2 Administration
Ease of doing business through detailed and updated
provision for streamlining the approval process in respect of
different agencies in the form of an integrated approval
process through single window approach, thereby
avoiding separate clearances from various authorities.
Updated provision on computerization of approval
process.
Reinforcement of the provisions on the mechanism of
ensuring certification of structural safety of buildings by
the competent professional and peer review of design of
buildings.
Fixation of responsibility for geotechnical engineer and
contractor, where involved in a building construction project.
31

Existing buildings / development (Cl 3.8)
Alternative materials/ design/ construction & tests (Cl 5)
Building notices and orders(Cl 7.2)
Construction not according to plan(Cl 7.5)
Modification and occupancy violation(Cl 7.6 & 7.7)
Integrated approval process(Cl 11.1.4)
Pre-Code Development / Building Permit(Cl 11.2)
Building plan for high rise/special buildings (Cl 12.2.5.1)
Notice for alteration only (Cl 12.4)
Duration of sanction (Cl 12.6)
Periodic occupancy renewal (Cl 14.4)
Unsafe building (Cl 15)
Demolition of building (Cl 16)
Architectural control (Cl 18)
32

Part 2 ADMINISTRATION
Clause 3Applicability
3.8 Existing Buildings / Development
33

PART 3
DEVELOPMENT CONTROL RULES AND
GENERAL BUILDING REQUIREMENTS
This Part deals with the development
control rules and general building
requirements to ensure health and
safety of the public.
34

35

36

37
-Land use classification and uses permitted
-Cluster planning approach and provisions for housing
-Inclusion of detailed town planning norms for various amenities
such as:
Educational facilities
Health care facilities
Socio-cultural facilities
Distribution services
Police, Civil Defence& Home Guards
Fire services
Telephone, postal and banking facilities
Sports activity
Shopping
Religious
Electrical substation
Transport
Cremation/Burial Ground, etc
PART 3
DEVELOPMENT CONTROL RULES AND
GENERAL BUILDING REQUIREMENTS

PART 3
DEVELOPMENT CONTROL RULES AND
GENERAL BUILDING REQUIREMENTS (contd…)
-Parking norms for metro & mega cities
-Special requirements for low income
housing in urban areas
-Special requirements for rural habitat
planning
-Special requirements for development
planning in hilly areas
-Provision for buildings & facilities for
persons with disabilities and the elderly
38

Major Modifications in
Part 3 Development Control Rules and General
Building Requirements
Modification of land use classification.
Modification of planning norms for various amenitiesprovided
in a city/town and also inclusion of provisions for new amenities.
Barrier free built environment: Comprehensive updated
provisions for accessibility in buildings and built environment
for persons with disabilities and the elderly by adopting
universal design principles.
Provisions on new planning and development norms, such as,
Transferable Development Rights (TDR)and Accommodation
reservation (AR).
Foreword of this part also refers to Transit Oriented Development
(TOD).
39

Major Modifications in
Part 3 Development Control Rules and General
Building Requirements
Updated requirements for fire tender movement keeping in view
availability of more equipped fire tenders of higher capacity.
Provisions for undergroundor multi-storeyed parkingas also mechanized
parking of vehicles.
Updated provisions on basementskeeping in view the latest
developments.
New provisions for solar energy utilization.
Updationof special requirements for low income housing and for
development planning in hilly areas.
Incorporation of requirements for upcoming buildings on podiumfor
ensuring fire and life safety in such buildings.
40

ACCESSIBILE BUILT ENVIRONMENT
Includes ease of independent –
approach,
entry,
evacuation, and/or
use of a building and its services and
facilities,
by all of the building’s potential users,
particularly including the elderly and
persons with disabilities, with an assurance
of individual health, safety and welfare during
the course of those activities.
41

REQUIREMENTS APPLY TO
•All buildings and facilities open to and used by the
public
•All forms of public housing by the government/civic
bodies or private developers.
•Private residences.
42
DOES NOT APPLY TO

43

44

Ugly implication of non compliance to building Codes

46
Year Major Fire Incident in the past No. of
Lives lost
No. of
Injured
1981 Bangalore circus fire > 92 > 300
1995 Dabwalifire accident, Haryana > 400 > 160
1997 UphaarCinema fire, New Delhi 59 103
1997 Religious congregation, Odisha 206
1997 Brihadeeswarartemple fire,
Thanjavur, T.N.
48 200
2001 Asylumat Erwadi,T.N. > 28
2002 Footwear factory, Agra > 42
2004 Kumbakonamschool fire, T.N. 94
2004 Srirangammarriage hall fire, T.N. 57 > 50
2005 Fireworks factory building,
Khusrupur, Bihar
32 >24
2006 Kolkata leather factory fire > 10

47
Year Major Fire Incident in the past No. of
Lives lost
No. of
Injured
2006 Consumer Electronicsfair, Meerut 65 > 150
2009 Jaipur oil depot fire 12 > 300
2010 Stephen Court fire, Kolkata > 43 > 20
2011 AMRI Hospital,Kolkata > 90
2011 Annual Convention, NewDelhi > 12 33
2012 Sivakasicracker factory,T.N. 54 78
2013 Kolkata market fire > 19 > 17
2015 Parliament complex, New Delhi
2016 National Museumof Natural History,
New Delhi
2016 Puttingaltemple fire, Kerala 111 > 350
2017 Kamala Mills Restaurant, Mumbai 14 55
2019 Commercial complex Fire, Surat 22 19

48
FIRE PREVENTION
LIFE SAFETY
FIRE PROTECTION
PART 4
FIRE AND LIFE SAFETY
Approach towards Fire and Life safety

49
SCOPE OF PART 4
ThisCode(Part4)coverstherequirementsforfireprevention,lifesafetyinrelationtofire
andfireprotectionofbuildings.ThisCode(Part4)specifiesoccupancy-wise
classification,constructionalaspects,egressrequirementsandprotectionfeaturesthat
arenecessarytominimizedangertolifeandpropertyfromfire.
The provisions of this Part are applicable to, all high rise buildings; and special buildings,
those are,
•hotel, educational, institutional, business, mercantile, industrial, storage,
hazardous and mixed occupancies, where any of these buildings havefloor
area more than 500 m
2
on any one or more floors;
•educationalbuildings having height 9 m and above;
•institutionalbuildings having height 9 m and above;
•all assemblybuildings;
•buildings, having area more than 300 m
2
of incidental assembly occupancy
on any floor; and
•buildings with two basements or more, or with one basement of area more
than 500 m
2
.
unless otherwise mentioned specifically in the provisions.
NOTE —The owner of the building and parties to agreement, may however, decide to
apply the provisions of this Part to buildings other than those given above.

50CONTENTS

51

52

53
65Terminologies 28Tables 16Figures 11Annexes
Part 4 to be read along withthe provisions in:
Readwith
Part
Title of the Part Reference
made in
Clause
Part 2 Administration 3.1.4, 3.2.7
Part 3 Development Control Rules and General Building
Requirements
3.4.4
Part 6/ Sec 8Structural Design: Glass and Glazing 3.4.10
Part 8/ Sec 1Building Services: Lighting and Natural Ventilation3.4.8
Part 8/ Sec 2Building Services: Electrical and Allied Installations3.4.6
Part 8/ Sec 3Building Services: Air Conditioning, Heating and Mechanical
Ventilation
3.4.8
Part 9/ Sec 4Plumbing Services: Gas Supply 4.8
Part 12 Asset and Facility Management 4.9,5.3

BUILDING OCCUPANCY CLASSIFICATION Clause 3.1
Group A Residential
Lodging or rooming houses (A-1)
One or two family dwelling (A-2)
Dormitories (A-3)
Apartment houses (flats) (A-4)
Hotels (A-5) & Starred hotels (A-6)
Group B Educational
Schools up to senior secondary level (B-1)
Others/training institutions (B-2)
Group C Institutional
Hospitals and Sanatoria (C-1)
Custodial institutions (C-2)
Penal & mental institutions (C-3)
Group D Assembly
D-1 to D-6 (Theatrical performances, auditoria, motion picture houses, concert halls,
stadia, amusement park, external swimming pool)
D-7 Underground and elevated MRTS
Group E Business
E-1 to E-5 (offices, banks, labs, computer, telephone exchanges, broadcasting
stations)
Group F Mercantile
F-1 to F-3 (shops, departmental stores, markets & underground shopping
centres)
Group G Industrial
Low hazard (G-1)
Moderate hazard (G-2)
High hazard (G-3)
Group H Storage
Group J Hazardous

MIXED OCCUPANCY
Fire Protection –most restrictive of the individual occupancies
applies to entire building
Life Safety –as per respectiveoccupancy
Exits–Size of egress should not decrease in the direction of travel
Occupancies to be separated by 240 min fire resistance rating
CHANGE IN OCCUPANCY
Building to be designed to comply with requirements of the new group/
sub-division
If new occupancy type is less hazardous –it need not conform to
requirements of the new Group/ sub-division
Certificate of occupancy before making change as per Part 2 (Annex P)
Alteration permit

FIRE PREVENTION
56
Building classification
Fire zones –Zone no. 1, 2 & 3 (used in Land Use Development
Plan)
Types of construction –Type 1, 2, 3 & 4
(based on fire resistance rating
of building elements)
Surface interior finishes -Classes 1, 2, 3 & 4
(Very Low, Low, Medium and
Rapid surface flame spread)
False ceiling, suspension fixtures -non-combustible
material
Fire ZonesOccupancy Group Type of
Construction
No. 1 A, B, C, D, E-1 (small offices), F
(including temporary buildings & structures)
1, 2, 3, or 4
No. 2 E-2 to E-5, G-1, G-2
(includingtemporary buildings & structures)
1, 2 or 3
No. 3 G-3, H, J 1 or 2

LIFE SAFETY
Requirements specified for: Reference at
Exit requirements Clause 4.2
Occupant load Table 3
Egress components Clause 4.4
Exit capacities and arrangement Table 4
No. of exits
Max. travel distance Table 5
Doorways, corridors & passageways
Staircases –pressurization Table 6
Ramps
Compartmentation Clause 4.5
Smoke control Clause 4.6
Illumination/escape lighting
Fire detection & alarm system Clause 4.9
Fire fighting shaft Fig. 2
57

General Requirements for All Individual Occupancies
Buildings under construction
Maximum height, FAR, open spaces (Part 3)
Openings in fire resistant walls, floors (Clause 3.4.5)
Service ducts and shafts
Refuse chutes
Vertical opening
Electrical installation (Clause 3.4.6)
Escape lighting, exit signage (Clause 3.4.7)
Air conditioning, ventilation, smoke control (Clause 3.4.8)
Heating (Clause 3.4.9)
Glazing (Clause 3.4.5)
Fire Command Centre (Clause 3.4.12)
58

FIRE PROTECTION
59Fire Fighting Installation
Fire extinguisher
First aid hose reel
Wet riser
Down comers
Yard hydrant
Automatic sprinkler system
Manually operated electric fire alarm system
Automatic detection and alarm system
Underground static water storage tank
Terrace tank over respective tower terrace
Pump near underground tank
Pump at terrace tank level
Dry riser (for hilly areas or industrial areas)
Fire protection requirements for high rise
buildings
Fire drill & evacuation procedures

Major Modifications in
Part 4 Fire and Life Safety
The scope of application of provisions of this Part for different
occupancies has been clarified.
FIRE PREVENTION
Table 1on fire resistance ratings of structural and non-structural
elements has been updated.
Detailed provisions on fire separating walls, fire separating
floors andfire partitions
Separate comprehensive clause on electrical power supply
distributionfor fire and life safety systems
Detailed provisions on air conditioning systems towards safety
and smoke control integration
Glass façade requirements have been detailed towards fire
protection and smoke exhaust aspects
Comprehensive clause on Fire Command Centre (FCC)
60

Major Modifications in
Part 4 Fire and Life Safety
LIFE SAFETY
Componentsof means of egress -exit access, exitandexit
discharge
Table on capacity factors -modified based on the aspect of
width per person approach used globally
Requirement for displaying the occupancy load for
assembly buildings and call centres.
Well integrated provisions on firefighting shaft to access the
floor on fire and also allows egress/evacuation of the
occupants with simultaneous use of refuge area.
Updated provisions on compartmentationwith fire barrier
and its passive fire safety requirements for respective
occupancies.
61

Major Modifications in
Part 4 Fire and Life Safety
FIRE PROTECTION
Erstwhile Table 23 on minimum requirements for fire fighting
installations (now Table 7) comprehensively updated.
Detailed provisions have been included on fire water storage, fire
pump room, sprinkler system and various alternative fire
suppression systems.
Detailed provisions on the concept ofprogressive evacuation in
case of hospital buildings.
Provisions on refuge area have been updated including for D-6
occupancy and introduced for apartment buildings of height 60
m and above.
Provisions specific to atrium, commercial kitchen and car
parking facilities.
Provisions specific to Metro Stations and Metro Trainways
62

63
FOR EXISTING BUILDINGS

Part 4 FIRE AND LIFE
SAFETY
Cl 3.1.12 –Change in Occupancy (of existing buildings)
64

Part 4 FIRE AND LIFE
SAFETYCl 3.2.7 Restrictions on Existing Building
65

66
CATEGORIES OF MATERIALS
AluminiumAnd Other Light
Metals And Their Alloys
Bitumen And Tar Products
Builder’s Hardwares
Building Chemicals
Building Limes
Cement And Concrete (Including
Concrete Reinforcement)
CememtMatrix Products
Clay Products For Building
Conductors And Cables
Doors And Windows
Electrical Wiring Fittings And
Accessories
Fillers, Stoppers And Putties
Floor Covering, Roofing And
Other Finishes
Glass
Gypsum Building Materials
Lignocellulosic Building Materials
(Including Timber, Bamboo And
Products Thereof)
Paints And Allied Products
Polymers, Plastic And Geosynthetics/
Geotextiles
Sanitary Appliances And Water
Fittings
Steel
Stones
Structural Sections
Thermal Insulation Materials
Threaded Fasteners And Rivets
Unit Weights Of Building Materials
Waterproofing And Damp-proofing
Materials
Welding Electrodes And Wires
Wire Ropes And Wire Products

67
NEW / ALTERNATIVE BUILDING
MATERIALS
Suitability for End Application
Strength Properties
Durability
Fire Resistivity
Thermal Properties
Acoustical Properties
Ease of Working/Handling
Energy Conservation/Environment Sustainability

Major Modifications in
Part 5 Building Materials
Updated provisions for ensuring utilization of
number of new/alternative building materials to
provide for innovationin the field of building
construction.
Examples of some potential new/alternative
materials.
New clause giving broad aspects relating to
sustainable materials.
Categories reclassified for ease of reference.
68

CERTIFICATION
BISoperatesathirdpartycertificationunder
theBIS(Certification)Regulations,1988
whichplaysaveryimportantroleinquality
assurance.Thethirdpartycertificationnot
onlyencouragestheproducers/beneficiating
agencybutalsoguidesthemforin-process
qualitycontrolincludingregardingthe
beneficiation,segregationandprocessing,
etc.
69

RMC CERTIFICATION
70

71

72

•https://www.thehindubusinessline.com/
bline/2001/04/19/stories/141967sk.htm
•https://www.tribuneindia.com/2001/200
10205/nation.htm#5
Buildings which complied with Codes
withstood Bhuj quake. Those which
were non compliant were total write off.
No Central Govt. building suffered any
major loss

PART 6
STRUCTURAL DESIGN 74
Section Title
Section 1 Loads, Forces and Effects
Section 2 Soils and Foundations
Section 3 Timber and Bamboo
Subsection 3ATimber
Subsection 3BBamboo
Section 4 Masonry
Section 5 Concrete
Subsection 5APlain and Reinforced Concrete
Subsection 5BPrestressedConcrete
Section 6 Steel
Section 7 Prefabrication, Systems Building and Mixed/ Composite
Construction
Subsection 7APrefabricated Concrete
Subsection 7BSystems Building and Mixed/Composite Construction
Section 8 Glass and Glazing (New)

75
2016 Wind Map

76

77

78
2016 Seismic
Zoning Map

79

80

81

82

83

84

85

86

Multi-Hazard Risk
in Various
Districts in India
Earthquake
Cyclone
Windstorm
Floods
Landslides
Liquefaction of soils
Extreme winds
Cloud bursts
Failure of slopes
87

139 Districts
6Districts
29Districts
16Districts
88

Major Modifications in
Part 6/Sec 3A Timber
Updated design provisions for timber connector joints, lamella
roofing, trussed rafters, etc.
The permissible lateral strength (in double shear) of mild steel
common wire for different new species of timberhave been
added and also strength values for some of the existing species
have been modified based on latest research.
Data on block shear test results of glued timber joints and on
strength properties of glued finger joints based on the indigenous
work, has been included for guidance in design.
Illustrations added for possible orientation of planks in glue
laminated beams(Glulam).
Designoutline for horizontally laminated beams has been added.
89

Major Modifications in
Part 6/Sec 3B Bamboo
Updated design provisions for
•bamboo trusses, and
•bamboo foundations.
Inclusion of provisions relating to use of
•bamboo as reinforcement in concrete,
•bamboo based materials/panel products as
walling/roofing material, and
•reconstituted wood from destructuredbamboo.
90

Major Modifications in
Part 6/Sec 4 Masonry
Inclusion of provisions relating to
•reinforced masonry,
•confined masonry building construction, and
•masonry wall construction using rat-trap bond.
New provisions related to durability criteria for selection of
masonry mortars.
Stabilized soil blocks have been included as masonry unit.
Number of storeysof masonry construction has been limited
to 4, in line with the seismic design standards.
91

Major Modifications in
Part 6/Sec 5A Concrete
Elaborated provisions relating to use of mineral admixtures,
their effects on properties of fresh and hardened concrete,
including precautions associated therewith.
Incorporation of permission to use aggregates from other
than natural sources, including iron slag aggregate, steel
aggregate, copper slag aggregate, bottom ash from thermal
power plant, and aggregate derived from construction and
demolition waste, through cross reference to revised IS 383.
Inclusion of stripping time required in case of concrete made
using cement other than OPC or using cementitiousmaterials
like fly ash and slag.
92

Major Modifications in
Part 6/Sec 5A Concrete
Provisions relating to self compacting concrete (SCC) and
high performance concrete (HPC).
Design provisions relating to steel fibre reinforced concrete
(SFRC) as part of special concretes.
Inclusion of provisions relating to shear stress for coupled
shear walls.
Inclusion of comprehensive provisions on ductile detailing
from IS 13920 : 2016 to help extensive implementation of
ductile detailing provisions in all relevant structures.
93

Coverage of
Ductile Detailing
94

95

Major Modifications in
Part 6/Sec 5B PrestressedConcrete
Updated design provisions for prestressedconcrete in line
with revised IS 1343:2012and latest practices.
Section on materials, workmanship, inspection and testing
has been completely modified in line with IS 456 as
applicable to prestressing.
Provisions related to bearing stress in the end zone in post-
tensioned members have been updated.
Provisions related to ultimate shear resistance of a section
uncrackedin flexure and also for that cracked in flexure have
been updated.
Test on wall thickness of the duct of corrugated HDPE
sheathing duct has been updated.
96

Major Modifications in
Part 6/Sec 6 Steel
The chapter has been modified in line with IS 800:2007 and latest
developments.
The table on tensile properties of structural steel products has
been updated by including yield stress values of bolts of sizes 3.6
to 6.8 mm as per IS 1367 (Part 3) and aligning the corresponding
provisions of the table with those given in IS 2062:2011.
Elaborated provisions for mechanical properties of structural steel.
Provisions related to effective wind pressure on exposed circular
tube members have been included.
Provisions related to requirement of temperature stress analysis
have been updated.
97

Major Modifications in
Part 6/Sec 7A Prefabricated Concrete
Inclusion of emulative system of prefabricated concrete with
detailed provisions in respect of its definition, analysis,
design, detailing, etc.
Detailed provisions on diaphragm action of floor systems
have been included.
Design considerations have been updated where accidental
impact due to vehicles has been included.
Provisions and testing procedures for water tightness of joints
have been included.
Some of the typical precast joint detailshave been illustrated.
98

Major Modifications in
Part 6/Sec 7A Prefabricated Concrete
Provisions relating to fire resistance testing of prototypes
under sustained load has been provided for.
Connection between adjacent prefabricated members only
through frictional resistance has been removed and
suggestions for resistance using shear has been included.
Provisions on site prefabrication have been updated.
Guidelines (restriction on the number of components) on
vertical stacking on ground have been included.
Provisions for tolerances in erectionand associated design
considerations have been included.
99

Major Modifications in
Part 6/Sec 7B Systems Buildings and
Mixed/Composite Construction
Updated provisions in respect of the following aspects of
systems building and mixed/composite construction:
•definition,
•analysis,
•design,
•detailing, etc.
Aspects relevant to devising systems and structural schemes
have been updated.
100

New Chapter
Part 6/Sec 8 Glass and Glazing
This new chapter on structural use of glass covers
•different types of glass, their requirements and associated
glazing materials;
•selection and application of glass in buildings,
•provision for glazing w.r.t. their effect on energy, visual
(light) and solar environments in the building;
•selection of glass in buildings, subject to wind loading,
seismic loading and special considerations for fire rated
glass and related materials;
•provisions for the selection and manifestation of glass in
buildings, subject to safety with respect to human impact of
the occupants; and
•provisions relating to selection, design, fabrication and
installation of glazing systems.
101

SELECTION OF GLASS
102

Application
Doors and Windows
Facade
Semi-Partitions (In-fill panels)
Mirrors
Atrium
Balusters
Railings
Greenhouses
Shop fronts
103

Types of Glass
Annealed Glass
‘A’ quality or ‘Selected Quality’ (SQ)
‘B’ quality or ‘Ordinary Quality’(OQ)
‘C’ quality or ‘Greenhouse Quality’ (GQ)
Float Glass
Tempered Glass (or Toughened Glass)
Heat strengthened glass
Laminated Glass
Reflective Glass
Wired Glass
Insulating Glass Unit (or Double Glass Unit)
104

Associated Glazing Materials
Setting Blocks
Location Blocks
Distant Pieces
Gaskets
Structural Sealants
Putty
Preformed Tapes
Glazing Beads
105

Factors to be considered in the
Selection of Glass
Location of glazed area (size, shape)
Implications of usage
Influence on performance
Security
Maintenance (access for cleaning and Reglazing)
Initial cost (capital cost)
Method of glazing (fixing the glass units)
Access for initial glazing
Protection during construction
106

Factors to be considered in the
Selection of Glass Contd..
Natural light
Glare
Fading
Privacy
Thermal consideration
Solar transmission
Heat absorption
Thermal insulation
Frame
107
Wind loading
Safety
Fire
Durability
Running cost
Maintenance cost
Life expectancy
Sound absorption

108

ENERGY AND LIGHT
109

110

111
EXTERNAL SHADING DEVICES

112
INTERNAL SHADING DEVICES

FIRE & LOADING
113

Loading Criteria
Calculation of Appropriate Glass Thickness (e.g. @ Annex D )
Net Design Wind Pressure as per IS 873 (Part 3), P
d
Decide Type and Size of Glass
General Check (Max. of pane area, span, AR), Table 16
Find effective wind pressure as per the type of glass, P
net& Table
15
Select trial thickness of glass (from Tables 19 to 27)
Calculate deflection at centreof glass panel, Annex C
Deflection to be less than allowable deflection, Cl 6.3.6.2
Check if selected thickness is safe from stress perspective, Table
14 & Empirical relation
Seismic Load as per IS 1893 (Part 1)
Design seismic force on the non-structural element, F
p
Seismic relative displacement
Structural bite for IGU
Handling, transportation, storage at site
114

Fire Safety
Part 4 ‘Fire and Life Safety’ of NBC 2016
ISO 834-Fire resistance tests --Elements of building
construction(Parts 1 to 13)
ISO 3009-Fire-resistance tests --Elements of building
construction --Glazed elements
115
TYPEOFGLASSFORFIRERESISTANCE
Wired glass
Annealed fire resistant glass (AFG)
Tempered fire resistant glass (TFG)
Gel laminated fire resistant glass (LFG)
Double glazed fire resistant glass (DFG)

SAFETY RELATED TO HUMAN
IMPACT
116

117

118
PART 3 OF NBC 2016

119
Manifestation

Test Requirements
Requirements Laminated Safety GlassToughened Safety
Glass
Impact/ Resistance to shock YES YES
Fragmentation test – YES
Warp test – YES
Boil test YES –
Fracture and Adhesion test YES –
Light stability test YES –
UV light test YES (for glass used in the
exterior portions and subject
to natural light)

Shot bag impact test YES YES
120

Glazing System (Guidelines)
Design and selection
Fabrication
Installation
Testing
Maintenance and durability
Minimum performance requirement of glazing in the building
exterior
Test requirements for coated glass
Shot bag impact test
Performance test
121

Important Standards utilized in
Part 6/Sec 8
IS No. Title
IS16231 Codeofpracticeforuseofglassinbuildings:
(Part1):2016General methodology and selection
(Part2):2016Energy and light
(Part3):2016Fireandloading
(Part4):2014Safetyrelatedtohumanimpact
122
All the above standards have been revised and are published as
IS 16231 (Part xx):2019

123
IS No. Title Current Stage
IS 15883 Construction Project Management-Guidelines:
Part 1:2009Part 1 General Published
Part 2:2013Part 2 Time Management Published
Part 3:2015Part 3 Cost Management Published
Part 4:2015Part 4 Quality Management Published
Part 5:2013Part 5 Health & Safety Management Published
Part 6:2015Part 6 Scope Management Published
Part 7 Part 7 Procurement Management Draft being prepared
Part 8:2015Part 8 Risk Management Published
Part 9:2018Part 9 Communication Management Published
Part 10 Part 10 Human Resource Management Draft being prepared
Part 11 Part 11 Sustainability Management Draft being prepared
Part 12:2016Part 12 Integration Management Published
IS 16416:2016Guidelines for Construction Project
Formulation and Appraisal
Published
IS 16601:2016Guidelines for Habitat and Welfare
Requirements for Construction Workers
Published
Construction Project Management

124
-Safety guidelines during different construction operations
such as during:
•excavation
•drilling and blasting
•piling and deep foundations
•tunneling
•road making
•at floor and wall openings
•demolition
•steel erection
•in construction of concrete framed structure
•during material handling
•while working in compressed air
•in use of tools
•in use of construction machinery
•from common hazards
-Concept of safety committees/management
-Maintenance management
SAFETY GUIDELINES

PART 7CONSTRUCTION
MANAGEMENT, PRACTICES AND
SAFETY

Major Modifications in
Part 7 Construction Management, Practices
and Safety
Updatedprovisionsforensuringutilizationofnumberof
new/alternativebuildingtechnologiestoprovidefor
innovationinthefieldofbuildingconstruction.
Incorporationofconstructionmanagementguidelinestoaid
intimelycompletionofbuildingprojectsinasafemannerwith
desiredqualityandwithinthebudgetedcost.
Inclusionofrequirementsforhabitatandotherwelfare
requirementsforworkmenatconstructionsite.
Updatedprovisionsonsafetyinconstruction.
126

PART 8
BUILDING SERVICES
127
Section Title
Section 1 Lighting and Natural Ventilation
Section 2 Electrical and Allied Installations
Section 3 Air Conditioning, Heating and Mechanical Ventilation
Section 4 Acoustics, Sound Insulation and Noise Control
Section 5 Installation of Lifts and Escalators and Moving Walks
Subsection 5ALifts
Subsection 5BEscalators and Moving Walks (New)
Section 6 Information and Communication Enabled Installations
(New)

Major Modifications in
Part 8/Sec1 Lighting and Natural Ventilation
Updated provisions relating to efficientartificial light source
and luminairesand photocontrolsfor artificial lights.
Inclusion of modern lighting techniques such as LED and
induction light vis-à-vis their energy consumption.
Reference to SP 41:1987 for obtaining coefficient utilization
for determination of luminous flux has been included.
Enabling provisions for lighting shelves and light pipes have
been included.
128

The provisions related to thermal comfort clause have been
elaborated including therein indices such as effective
temperature, adaptive thermal comfort along with
elaborations on tropical summer index.
Design guidelines for natural ventilation have been
elaborated with illustrations.
Provisions related to determination of rate of ventilation
particularly on combined effect of wind and thermal actions
have been elaborated.
Provision on colour rendering has been included in line with
that in SP 72 : 2010 ‘National Lighting Code 2010’.
129
Major Modifications in
Part 8/Sec1 Lighting and Natural Ventilation

Major Modifications in
Part 8/Sec 2 Electrical and Allied Installations
Updationof the chapter for ensuring alignment with The
Indian Electricity Act, 2003 and various CEA Regulations
framed thereunderparticularly Central Electricity Authority
(Measures Relating to Safety and Electric Supply) Regulations,
2010.
Updated provisions on location and other requirements
relating to layout, environmental and safety aspects for
different substation apparatus/equipment and generating
sets.
Inclusion of provisions relating to location of compact
substations.
Updated provisions for reception and distribution of supply
and wiring installations and for installation of energy meters
with due cognizance to the Indian Standards formulated.
130

Revised provisions for earthing/grounding.
Comprehensive revision of provisions relating to lightning
protectionof buildings.
Inclusion of provisions relating to renewable energy sources
for building, such as solar PV system; aviation obstacle lights;
electrical supply for electric vehicle charging and car park
management; etc.
New provisions relating to electrical installations for
construction sites and demolition sites.
Inclusion of provisions relating to protection of human
beings from electrical hazards and protection against fire in
the building due to leakage current.
131
Major Modifications in
Part 8/Sec 2 Electrical and Allied Installations

Major Modifications in
Part 8/Sec 3 Air conditioning, Heating and
Mechanical Ventilation
Modified provisions on refrigerants for air conditioning to
include new refrigerants with zero ODP and ultra-low GWP
including natural refrigerants.
Inclusion of other available options of HVAC such as, VRF
system, inverter technology, district cooling system, and
hybrid central plant using chilled beams, radiant floor
components, geo-thermal cooling and heating, etc.
Thrust on envelope optimization using energy modelling, day
lighting simulation, solar shade analysis and wind modelling
software to optimize the air conditioning load.
Indoor design conditions for comfort HVAC now based on
adaptive comfort conditions for the specific climatic zone.
132

Updated provisions on HVAC requirements for data centres
and healthcare facilities and inclusion of such requirements
for underground metro stations.
Incorporation of refrigeration for cold stores.
Inclusion of most efficient strategies for winter heating, using
reverse cycle operation, solar heating systems, electric heat
pump, and ground source heat pump.
Coverage of modern system of mechanical ventilation for
industries, commercial kitchen, underground car parking, and
for open tunnels connecting underground metro stations.
Updated provisions on building automation system to
include the latest practices for web-based monitoring and
control of performance parameters.
133
Major Modifications inPart 8/Sec 3

Major Modifications in
Part 8/Sec 4 Acoustics, Sound Insulation and Noise Control
Updated provisions on sound insulation and noise control
measures in buildings.
New clause on construction noise.
The provision relating to noise control in open plan schools
has been deleted, owing to the changed scenario.
Reverberation times of classrooms and assembly halls in
schools have been modified.
Requirement of insulation (Rw) for walls or partitions between
rooms in hospitals have been modified.
Recommended maximum reverberation time for very large
offices and for canteens have been modified.
134

Requirement of insulation (Rw) for walls or partitions between rooms
in hospitals have been modified.
Green belts & public garden acts as buffer zone to separate traffic
noise from hospital s
Honking is prohibited
Acceptable indoor noise levels –35-40 dBA
Clause 7 for HOSPITAL BUILDINGS
Source: Outdoor noise
Indoor noise
Recommendation: Site planning,
Detailed planning,
Reduce noise at source
Use resilient material
Sound insulation
Sound absorption
ACOUSTICS, SOUND INSULATION & NOISE CONTROL

Major Modifications in
Part 8/Sec 5A Lifts
Inclusion of requirements for high speed lifts and lifts for tall
buildingsincluding elaboration of lifts for fire-fighting and
emergency evacuationand inclusion of considerations for
machine room less (MRL) lifts.
Updation of preliminary design provisions for lifts to cover the
requirements for various building functions.
Inclusion of provisions for seismic resistance aspects in lifts.
136

New Chapter
Part 8/Sec 5B Escalators and Moving Walks
This new chapter on escalators and moving walks covers all
aspects relating to their
•Planning;
•Installation;
•Operation, maintenance; and
•Inspection
for ensuring safe movement of people with satisfactory
performance.
137

New Chapter
Part 8/Sec 6 Information and Communication Enabled Installations
This new chapter on information and communication enabled
installationscovers
•essential requirements for ICT installations;
•technology systems and cabling installations in a building;
•general guidelines required for planning and providing ICT
services in the building at the planning and execution
stages;
•basic design and integration requirements for
telecommunication spaces within building/buildings along
with their cabling infrastructure, their pathway components
and passive connectivity hardware; and
•general requirements relating to installation of different
communication equipment, cable terminations and power
connections.
138

PART 9
PLUMBING SERVICES
Section 1 Water Supply
Section 2 Drainage and Sanitation
Section 3 Solid Waste Management(New)
Section 4 Gas Supply
139

Major Modifications in
Part 9/Sec 1 Water Supply
Water supply requirements for buildings based on estimated
occupancy in the chosen type of building.
Updation of water requirements for non-residential buildings
with separate domestic and flushing requirements.
Updation of number of various water supply fixture unit and
probable simultaneous demand, with demand values up to
10,000 fixture units.
Updated provisions for water supply distribution systems in
multi-storeyed buildings with illustrations therefor.
Inclusion of provisions relating to swimming pools.
140

14
1

Major Modifications in
Part 9/Sec 2 Drainage and Sanitation
Various additional requirements relating to layout of drainage
and sanitation system have been added.
Inclusion of provisions on venting system for high rise
buildings.
Updationof number of various drainage fixture unit.
Revised sizes of rainwater pipes for efficient roof drainage.
Updated provisions on rainwater harvesting and artificial
ground water recharge.
142

New Chapter
Part 9/Sec 3 Solid Waste Management
This new chapter on solid waste management covers
•various solid waste management systems,
•assessment of per capita solid waste quantities, and
•treatment of solid waste within the building, building complexes
and their built environments.
References to latest applicable statutory Rules and Regulations
have been included.
An informative Annex relating to municipal solid waste generation
has been included, covering quantity,type, description and
sources of solid waste generation.
An Annex relating to treatment of food waste has also been
included.
143

Infected waste –Pre-treat, sterilise
Pre-wash soiled linen in dirty utility room & sterilized before
regular wahing
Neutralize liquid waste to prevent cross contamination
Radioactive Wastes
14
4
DRAINAGE & SANITATION
SOLID WASTE
Radioactive Wastes
Pathological Wastes
Toxic Wastes
Bio-medical Wastes
-Anatomical,
-Micro-biological
-Biotechnology
-Waste sharps
-Discarded medicine
-Soiled waste
-Incineration ash
-Chemical waste

Major Modifications in
Part 9/Sec 4 Gas Supply
Revised provisions on LPG supply in buildings
Detailed provisions on PNG supply in buildings
New provisions on medical gas pipeline system
145

PART 10
LANDSCAPE DEVELOPMENT,
SIGNS AND OUTDOOR DISPLAY
STRUCTURES
Section 1 Landscape Planning, Design and
Development
Section 2 Signs and Outdoor Display Structures
146

Major Modifications in
Part 10/Sec 1 and 2
Updated provisions on landscape planning, design and
development and signs and outdoor display structures.
New clause on landscape site planning requirements.
A new clause relating to roof landscape has been added.
New provisions related to materials and finishes plan have
been included as part of the landscape development
documents required for statutory approvals.
Part 10/Sec 2 has been linked with Part 3 of the Code for
ensuring appropriate controls of signs as applicable for the
purpose of accessibility for persons with disabilities
147

Major Modifications in
Part 11 Approach to Sustainability
Updation of the new Part 11 ‘Approach to Sustainability’
which was added to NBC 2005 through its Amendment No. 1
for covering guidelines for making buildings and built
environment energy efficient and environmentally compatible.
Covers all aspects of energy conservation such as electrical
energy conservation, water conservation, use of low
embodiedenergy materials, renewable energy utilization, etc.
The chapter is intended to help in meeting relevant
sustainable development goals (SDG)laid down by the
United Nations.
148

OUTLINE OF
PART 11APPROACH TO SUSTAINABILITY
1 SCOPE
2 TERMINOLOGY
3 APPROACH TO SUSTAINABILITY
4 APPLICAPABILITY OF THIS PART OF THE CODE
5 SITING, FORM AND DESIGN
6 EXTERNAL DEVELOPMENT AND LANDSCAPE
7 ENVELOPE OPTIMIZATION
8 MATERIALS
9 WATER AND WASTE MANAGEMENT
10BUILDING SERVICES OPTIMIZATION
11CONSTRUCTIONAL PRACTICES
12COMMISSIONING, OPERATION, MAINTENANCE AND
PERFORMANCE TRACKING
149

Conceptualization
SUSTAINABILITY ISSUES IN BUILDING ACTIVITY
(Contd…)
Location/Siting
Environment and ecological concerns of site
Landslide hazard vulnerability (IS 14496)
Seismic hazard vulnerability (IS 1893)
Potential environmental impact of building occupancy
Recycle and reuse of wastes

Planning
SUSTAINABILITY ISSUES IN BUILDING
ACTIVITY
(Contd…)
Orientation
Natural lighting and ventilation (SP 41)
Use of shading devices and vegetation cover
Efficient supplementary lighting and ventilation
Open spaces in and around building
Thermal insulation
External Development

Selection of Building Materials
SUSTAINABILITY ISSUES IN BUILDING ACTIVITY
(Contd…)
Impact during production, haulage, construction and
deconstruction
Industrial and agricultural waste based materials
-Fly Ash (IS 3812) & fly ash based materials, Slag (IS 12089),
GGBS (IS 16714), Ultrafine GGBS (IS 16715),
Sintered Aggregates (IS 9142),
Lignocellulosic Panel Products
Plantation timber
Bamboo (IS 15912)
Renewable natural materials of low gestation period
Efficient manufacturing technologies
Aggregates from other than natural sources (IS 383)

Structural Design
SUSTAINABILITY ISSUES IN BUILDING
ACTIVITY
(Contd…)
Structural safety as environmental saviour of embodied
energy
Limit State Design –exploitation of material potential
Flyash / Slag concrete
Durability (IS 456 & IS 800)
Prefabrication and systems building approach
(IS 15916, 15917)

Constructional Practices and Management (IS 15883)
SUSTAINABILITY ISSUES IN BUILDING
ACTIVITY
(Contd…)
Minimizing adverse environmental impact of activities.
Limiting any adverse impact within the laws/prescribed norms
and their monitoring.
Safety of environment while working with hazardous materials
and maintaining Material Safety Data Sheets.
Management of disposal of waste from construction sites.
Considering positive environmental contribution.
Mechanism to review concerns of interested parties.
Best construction management / practices.

Building Services
SUSTAINABILITY ISSUES IN BUILDING
ACTIVITY
(Contd…)
Lighting and ventilation
Electrical Installations
HVAC
Sound Insulation and Noise control
Lifts and Escalators
Information & Communication Enabled Installations

Plumbing Services
SUSTAINABILITY ISSUES IN BUILDING
ACTIVITY
(Contd…)
Water Supply
Dual Water Supply Systems
Recycle and Reuse of wastes
Drainage and Sanitation
Rain Water Harvesting
Special Wastes

COMPREHENSIVEAPPROACH
Dealswithallaspectsrelatingto:
•Siting, Form and design;
•External development and landscape;
•Envelope optimization;
•Selection of appropriate materials;
•Water and waste management;
•Building services optimization;
•Constructional practices including selection of
appropriate technologies;
•Commissioning, operation, maintenance and
building performance tracking.

SITING, FORM AND DESIGN
•Protection of natural resource areas like
floodplains; forests; water bodies; public
parks; and agricultural land.
•Least disturbance to existing soil at site
and hydrology and preserving top soil
•Removal of existing invasive vegetation
on site and ensure none such planted
post completion

EXTERNAL DEVELOPMENT AND
LANDSCAPE
•Ensure proper landscape design including:
a.microclimatic conditions,
b.barrier free external landscape,
c.noise reduction/mitigating practices,
d.pervious paving design,
e.avoiding heat-island effect,
f.preserving top soil,
g.rain water harvesting
•Reduce environmental impacts from parking
facilities
•Promote mass rapid transit systems, provide
for bicycle lanes and pedestrian access

ENVELOPEOPTIMIZATION
•Building envelope to
•conserve energy substantially.
•maximise daylight,
•maximise natural ventilation (access to fresh air)
•modulate solar heat gain and control
•integrate systems for renewable and rainwater
harvesting
•Proper selection of components of
•walls,
•roof,
•fenestration (openings with or without glazing),
•floor,
•surface finishes
•screens (jalli)

MATERIALS
•Environmental Concerns and Human Health and Safety
•depletion of non-renewable natural resources due to
extraction of raw materials,
•disposal of the wastes generated,
•transportation of materials,
•Volatile Organic Compounds (VOCs) released during
manufacture or processing of certain materials,
•Minimizing Green House Gas (GHG) Emission
•Selection of Building Materials
•Life Cycle Assessment (LCA) of Building Materials
involving
•Embodied energy
•Resource reuseand upgradation
•Recycled content
•Materials compliant with clean air and clean water, etc

LIFE CYCLE ASSESSMENT
Embodied Energy
Resource Reuse and Upgradation
Recycled Contents
Reusablity / Recyclability
Natural and Plentiful
Indigenous / Locally Available
Rapid Renewability
Non-Polluting / Non-Hazardous

WATERANDWASTE
MANAGEMENT
•Integrated approach to water supply, water
waste and solid waste management in
•Conceptualization, planning and design stage
•Construction stage
•Performance during use and corrective action,

BUILDINGSERVICESOPTIMIZATION
•Optimization of electro-mechanical services
•Solar passive techniques suiting different climate zones
•Key target issues to be addressed
•Building orientation
•Building envelope
•Design assumptions and internal load assessment
•Maximize efficiency
•Energy efficient design of electrical installations in
buildings
•Minimizing losses in the power distribution system,
•Reduction of losses and energy wastage in the utilization of electrical
power,
•Reduction of losses due to the associated power quality problems
•Appropriate metering and energy monitoring facilities.

NBC2016recommendseffortsforutilizingtherenewable
energyavailableinvariousformslike,
Solarenergyutilization
1)Solarwaterheatingsystems
2)Solarsteamsystemsforcooking,laundry,etc.
3)Solarassistedrefrigeration/airconditioningsystems
4)Solarphotovoltaicsystems
Windenergyutilization
WasteUtilization
1)Wasteheatutilization
2)SolidWasteUtilization
Bio-Fuels
Hydropower
OtherRenewableEnergySources
16
5
BUILDINGSERVICESOPTIMIZATION

NBC2016:Part3‘DevelopmentControlRulesandGeneral
BuildingRequirements’coversdetailedadministrative
provisionsforsolarenergyutilization.
PrescribesinstallationofSolarPhotovoltaicPower
GenerationSystemforallplotshavingsize500m
2
and
above.
Alsoencouragessuchinstallationsforplotssmallerthan
500m
2
.
16
6
BUILDINGSERVICESOPTIMIZATION

OtherprovisionsinthisrespectinPart3oftheCode:
a)Installationofeithersolarpanelsonrooftops,orintegrated
photovoltaicpanelsonwalls/windows,orsolarphotovoltaic
(PV)banksonopenareas.
b)Utilizationofpowersogeneratedforeitherin-houseorfor
transfertothegrid.
c)TheAuthoritiestohaverequiredprovisionsinthebuilding
bye-lawsandmechanismforrequiredclearancesand
approvals.
d)TheAuthoritytoalsospecifyminimumgeneration
requirement.
e)TheCodealsoprovidesguidanceforminimum
generationrequirements.
16
7
BUILDINGSERVICESOPTIMIZATION

TheCodealsoprescribesrequirementofinstallationof
SolarWaterHeatingSystemforthefollowingbuilding
occupanciesforsupplyinghotwater:
a)Residentialbuildings(excepthostelsofeducational
buildingsandplottedhouses)havingplotarea4000m
2
andabove;
b)Plottedhouseshavingplotareaof250m
2
andabove;
c)Hostelsforschools,collegesandtrainingcentresfor
morethan100students;
d)Institutionalbuildings;and
e)Assemblybuildings.
16
8
BUILDINGSERVICESOPTIMIZATION

OtherprovisionsinthisrespectinPart3oftheCode:
i)TheAuthorityshallhaverequiredprovisionsinthe
buildingbye-lawsandmechanismforrequired
clearancesandapprovals.
i)TheAuthority,consideringtheavailabilityofsolarenergy
forharnessing,shalldecidetheminimumcapacitytobe
installedsubjecttoaminimumof25litreperdayhot
wateryieldforeachbathroomandkitchen.
16
9
BUILDINGSERVICESOPTIMIZATION

Forsolarwaterheatingsystemandtheirinstallation,
referencetofollowingIndianStandardsshouldbemade:
IS12933Solarflatplatecollector—Specification
(Part1):2003Requirements(secondrevision)
(Part2):2003Components(secondrevision)
(Part3):2003Measuringinstruments(firstrevision)
(Part5):2003Testmethods(secondrevision)
IS12976:1990Solarwaterheatingsystems—Codeof
practice
17
0
BUILDINGSERVICESOPTIMIZATION

NBC2016initsPart9/Section1coversprovisionsrelatingto
installation(includingpiping)forsolarassistedwater
heatingsystems.
NBC2016initsPart8/Section2recommendstoplan
buildingselectricalservicesinamannertointegratewith
alternatesourcesofenergysuchassolarenergy.
TheCodeinitsabovechapteralsocoversprovisionsrelatingto
electricalinstallationsofSolarPhotovoltaicPowerGeneration
System.Lightningprotectionforbuildingswithroof-topsolar
PVsandwaterheatingsystemsandlargesolarPVpower
plants/farmsisalsocoveredinthischapteroftheCode.
17
1
BUILDINGSERVICESOPTIMIZATION

NBC2016initsPart8/Section3‘BuildingServices,Air
Conditioning,HeatingandMechanicalVentilation’covers
provisionsrelatingtoutilizationofsolarheatenergyfor
heatingbuildings.
Also,variouspassiveheating(likesolarchimneys,trombe
walls,etc)andpassivecoolingtechniques(nocturnalcooling,
courtyards,etc)havebeendiscussedinPart11oftheCode.
NBC2016initsPart11alsoprescribesuseofSolar
PhotovoltaicSystemsforlightingpurposeinremotenon-
gridareas.TheuseofcommonSPVlightingsystems,a)Solar
lantern,b)Fixedtypesolarhomelightingsystem,andc)Street
lightingsystemhasbeenprescribed.Guidingprovisionsontheir
usehavebeenprovided.
17
2
BUILDINGSERVICESOPTIMIZATION

CONSTRUCTIONALPRACTICES
The framework for sustainable construction practices includes
the following issues:
•Pre-construction pre-requisites
•Planning for sustainable construction
•Preparation of sustainable construction management plan
•Planning, monitoring and control of environmental descriptors
•Sustainable work execution procedures
•Effective use of water
•Construction waste management
•Post-construction closeout
•Construction methodology for heritage buildings
•Alternative use, de-construction, dismantling, demolition.

COMMISSIONING, OPERATION, MAINTENANCE
AND BUILDING PERFORMANCE TRACKING
•Formationofcommissioningteamcomprisingowner,users,occupants,O&M
staff,anddesignprofessionalsandowners.
•Projectdesigndocumenttoincludeacommissioningplan.
•O&Mprogrammestofocusonimprovingenergyefficiencyofbuildingsystems.
•Goodmaintenancepracticestobeimplementedforsubstantialsavingsin
consumptionofenergyandwater.
•Regularmonitoringoftheperformancetobecarriedoutwhichwillprovide
informationonwhetherthesetenvironmentalperformanceandtargetshave
beenmetornot.
•Measurementandverification(M&V)processtocovermonitoringoftheenergy
andwatersystemstoensureongoingaccountabilityofenergyandwater
consumptionduringthelifeofbuilding.

17
5
SOMEPOINTSREGARDING
SUSTAINABILITY
-To get the maximum benefit from the building and its services in
terms of quality, timely completion and cost-effectiveness.
-The aim is to maximize the efficiency of the total system through
appropriate optimization of each of its sub-systems.
-In the team, the inputs from each of the professional disciplines
have to be so optimized that the total system’s efficiency becomes
the maximum.
-It may be re-emphasized that maximizing the efficiencies of each
sub-system may not necessarily assure the maximization of the
efficiency of the total system.

PART 12 ASSET AND FACILITY
MANAGEMENT
17
6

17
7

New Chapter
PART 12 ASSET AND FACILITY MANAGEMENT
This new chapter on asset and facility management covers
•provisions relating to management of building assets and
associated services;
•provisions to deal with issues relating to maintenance of all
types of facilities and fixed assets such as buildings and
building services (includes both hard and soft services such
as building fabric maintenance, roads and pathways,
security, MEP services including fire safety
installations, housekeeping, etc;
•Provisions for identifying critical activities and critical
assets which need to be focused upon by facility managers;
and
•responsibilities of occupants for maintenance of facilities,
such as, structures, equipment and exterior property.
178

ADOPTION OF NBC -WAY FORWARD
Mega Cities (8)
Population of over 50 Lakhs–Delhi,
Mumbai, Kolkata, Chennai, Bangalore,
Hyderabad, Ahmedabad, Pune
Metro Cities (45) 10 to 50 Lakhs
Municipal
Corporations (121)
5 Lakhs and above
City Municipalities
(A class)
1 Lakhand above
Town Municipalities
(B &C class) / Town
Panchayats
5,000 –1,00,000
Rural Areas
179
53 million plus cities/urban agglomerations –70 by 2021

18
0

18
1

18
2

https://ndma.gov.in/images/policyplan/dmplan/National%20
Disaster%20Management%20Plan%20May%202016.pdf
18
3

ENFORCEMENT
184
Building Byelaws
Building Rules
Planning Standards
Development Control Rules
Fire Regulations
Town Planning Rules
Hazard Mapping Rules
Water Supply Byelaws
Drainage Byelaws
These regulatory
documents have
to be brought in
line with
NBC 2016
The Building Regulatory Media consist of

THEPUBLICATION
Volume
1 and 2
Comprehensive version (Parts 0 to 12 –all
sections included)
Rs. 13,760/-
Group 1For Planning,
Building/ Land
Development work
(Parts 0, 1, 2, 3, 4, 5,
10 –Sections 1 & 2
and Part 11)
Rs. 4,650/-
Group 2For Structural Design (Part 0, 6 –Sections
1 to 8 and Part 11)
Rs. 6,020/-
Group 3For aspects relating to
Construction
Management, Practices
and Safety and Asset and
Facility Management
(Part 0, 7, 11 and
Part 12)
Rs. 2,380/-
Group 4For Building Services (Part 0, 8 –Sections
1 to 6 and Part 11)
Rs. 4,300/-
Group 5For Plumbing Services (Part 0, 9 –Sections
1 to 4 and Part 11)
Rs. 2,710/-
185

18
6

18
7

18
8

BIS Website: www.bis.gov.in
Contact us: [email protected]
189
THANKS FOR YOUR KIND
ATTENTION