Zennio HVAC Training - Slides


Slide Content

Australia
KLIC (HVAC RANGE)

AVAILABLE
Compatibility
Mitsubishi DaikinSamsung Fujitsu LG
Toshiba Panasonic IRSC

AVAILABLE
Zennio benefits:
Bi-directional (All except some IR AC units)
Analogue inputs (temp probe, motion sensor, push button or window contacts)
Free Floating Logic functions included. Zoning and aggregate temperatures
Error handling
Master / Slave option
Simplified mode (heat / cool only)

FINDING COMPATIBILITY
https://www.zennio.com/products/knx/hvac/air-conditioner
Go to Zennio webpage:
Choose brand and type (industrial / commercial / etc)
Click compatibility table

FINDING COMPATIBILITY
Find the Model
Check AC remote

DAIKIN SYSTEMS
Daikin Industrial (VRV & SKY)
VRV, SKY,
Chosen in ETS
application program
KLIC-DI v2 KLIC-DD v3
Daikin Residential (split & concealed)
May need adapter card:
(BRP067A42, OR BRP980B42)

DAIKIN FIELD SETTINGS
By others - YouTube video showing:
https://www.youtube.com/watch?v=aIMixgiSjkM
Field Settings
202-01 Sense from both wall r/c and return air
202-02 Use unit air sensor only/ return air
202-03 Sense from wall controller only
Screen share Daikin controller

MITSUBISHI SYSTEMS
Option: IT signal adapter available. KLIC-MITT CN100 (9900019)
Fits the Mitsubishi circuit board connector CN100

SEE ETS PROGRAM
Ets Screen Share
Parameters &
Group Address’s

ZONE LOGIC EXAMPLE
HVAC Zone Control
4 Zone. 1 head unit
Trigger : 1 bit data entry 1, 2, 3, 4.
Condition : Nil
Operation 1 : 1 bit data entry 1, or 1 bit data entry 2, = b1
Operation 2 : b1 or 1 bit data entry 3, = b2
Operation 3 : B2 or 1 bit data entry 4, = b3
Result : B3 no restriction, always.

ZONE LOGIC PROGRAM
Configuration : 4 x 1 bit data entries
Linking : 1 bit data entry 1, 2, 3, 4 link to zone on / off
Function result : Link to on / off of main AC unit
Group address links
HVAC Zone Control
4 Zone. 1 head unit

DESIGN EXAMPLE
Make open area a
spill zone (always open)
Take aggregate temperature
to send to main unit.
Eg 50/50, guest bed/family

AGGREGATE TEMPERATURE
Take aggregate temperature
to send to main unit. Logic
Eg 50/50,
Thirds, etc
Show in ETS Logic.
Addition,
Division by qty

END OF SESSION
Please email :
[email protected], or
[email protected]
For a copy of the ETS project.