20-2-2025 supplier line rejection at TitanX Saltillo Tanque Autoplastek.pptx
AxelMata3
82 views
11 slides
Feb 26, 2025
Slide 1 of 11
1
2
3
4
5
6
7
8
9
10
11
About This Presentation
ttt
Size: 23.21 MB
Language: en
Added: Feb 26, 2025
Slides: 11 pages
Slide Content
Line Rejection On TitanX Saltillo Line Rejection On TitanX Saltillo.
Incident description: Line rejection information Part Name : Tank Autoplastek Part Number : Issue : Leakage of valvule
Incident description: What happened? Leakage of Valvule Why is it a problem? Tank position When is it detected? February 20, 2025 Who detected it: Axel Mata Where is it detected? Production area How is it detected? Leak Tester
Incident description: Leakage of valvule
Incident description: Tank assembly and accommodation
Incident description: Fixture not suitable for that part number
Incident description: Before fitting the tank . After fitting the tank .
Incident description: There is no specific quality alert for this part number. There is no specific manufacturing instruction for this part number.
Incident description: Tank autoplastek fixture for two different suppliers and references, does not meet the specifications of one.
Incident description: There is no specific manufacturing instruction for this part number.