3_DANFOSS turbocore compressor presentation

JohnMaulana1 73 views 15 slides Jul 13, 2024
Slide 1
Slide 1 of 15
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15

About This Presentation

Danfoss


Slide Content

INTRODUCTION TO DANFOSS
TURBOCOR COMPRESSORS David Williamson Sales Manager – Europe & Middle East region
April 14, 2016

12-4-2016 2
Danfoss Turbocor Compressors
•Agenda
–Introduction
–The Turbocor portfolio
–Chiller design considerations
–Typical chiller EER/ESEER
–Danfoss Turbocor with HFO refrigerants
–Summary
–Question and answer session

Introduction to Danfoss Turbocor
Inverter speed
control
Synchronous brushless
DC motor
Motor and
bearing control
Inlet guide
vanes
2-stage centrifugal
compressor
Soft-Starter
Pressure/temperature
sensors

Typical compressor maps
30
50
70
90
110
130
150
10 20 30 40 50 60 70
Saturated Suction Temperature SST [F]
Saturated Discharge Temperature SDT [F]
-1
9
19
29
39
49
59
-12 -7 -2 3 8 13 18
Saturated Suction Temperature SST [C]
Saturated Discharge Temperature SDT [C]
Turbocor TT300 Turbocor TT350 Turbocor TT400 Turbocor TT500 Turbocor TT300 MT
Air cooled or water cooled
Water cooled

Refrigeration Capacity (Tons)
Danfoss Turbocor Compressor family
0 200
400
600
800
1000
1200
1400
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400
TG520 90-15- TR
TG390 70-120 TR
TG310 60-90 TR
TG230 40-70 TR
TT700 130-200 TR
TT400 90 150 TR
TT350-70 120TR
TT300-60 90 TR
VTT1200 Up to 350 TR
VTT880 Up to 250 TR
VTT1000 Up to 300 TR
TG Series
Refrigeration Capacity (kw)
Danfoss Turbocor Compressor Portfolio

Typical screw chillerTypical oil-free chiller
•Simple
•Fewer connections
•Higher efficiency
•Less maintenance
•Higher reliability Oil free reduces complexity

Heat exchanger technology
•Evaporator
–Shell and tube flooded –low
approach temperature. Multiple
compressors. Up to 2 circuits.
–Falling film –reduced
refrigerant charge
–New technology spray plate
exchanger. Very low refrigerant
charge. Single compressor
application suitable for modular
design.

Heat exchanger technology
•Condenser
–Shell and tube (water cooled).
Multi compressors. Single or dual
circuit.
–Spray plate (water cooled). Single
circuit, single compressor for
modular chiller design
–Fin and tube (air cooled)
–Micro channel (air cooled)

Economiser options
•Plate heat exchanger
•Open flash tank
–Choice between increasing cooling capacity or
increasing efficiency (or mixture of both)
–Most OEMs offer chillers with or without
economiser

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Chiller Efficiency [kW/Ton]
Chiller Load [%]
Single Oil Centrifugal VSD Single Oil Free Centrigufal VSD Multiple Oil Free Centrifugal VSD
Oil free enables multiple compressor
benefit
Multiple oil-free compressors improve energy efficiency at low load
operation

Typical chiller EER and ESEER
•Typical EER for air cooled chillers 3.45 to 3.84
•Typical ESEER 5.55 to 5.82
•Available with free cooling option
•Typical EER for water cooled 5.25 to 5.5
•Typical ESEER >8.0

Danfoss Turbocor with HFO
refrigerants

Danfoss Turbocor with HFO
refrigerants

Extremely lightweight and compact

Soft startup with low in-rush current

Available for 380 – 460 Volt applications

Nominal capacity: 230kW, 310 kW,
390kW, and 520 kW

Fastest restart time in the industry of
less than 30 seconds without the use of
an external universal power supply.

High efficiency at full load and
extraordinarily high efficiency at part
load conditions

Summary
•Industry leading part load efficiency
•Low maintenance
•Overall life cycle cost savings compared to
other compressor technologies
•Options for ultra low GWP refrigerants
•Suitable for data centre cooling, commercial
building air conditioning and industrial
applications.

•Questions?