3_Networking and configuration of ZXJ10.ppt

ssuser49005f 7 views 18 slides Oct 08, 2024
Slide 1
Slide 1 of 18
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18

About This Presentation

Networking and Configuration


Slide Content

Agenda
•Networking Mode
•Traffic Calculation

Networking Mode
SM
Single Module
CM
SM SM
SM
SM SM
Networking with SM as central
SM SM
Networking with CM as central
Note:
SM can be used independently. But CM can not.
SM carries RSU, but CM does not.
PSM (Peripheral Switching Module) : uses FBI
board as the uplink to the upper module
RSM (Remote Switching Module): uses DTI/ODT
board as the uplink to upper module
FBI DTI/ODT
DTI/ODTFBI

Networking Mode
•Single Module
–SM16, SM8, SM4C, SM4I
•SM as central
–SM16, SM8
•CM as central
–CM256, CM128, CM64, CM32
•PSM
–SM16, SM8
•RSM
–SM16, SM8, SM4C

Inter-office Trunks
–SDT board
•STM-1 interface:
•Bandwidth: 63 E1
–E1
•DTI: 4 E1 ports; MDT: 16 E1 ports
•Bandwidth : n*E1

Inter-module Trunks
–FBI board
•Used between PSM and its host module
•Inter-module trunks: 16 * 8M =16*128=2048DT, 8 of them for
inter-module communication
–ODT board
•Used between RSM and its host module
•Inter-module trunks : 4*8M=4*128=512DT
–E1
•Used between RSM and its host module
•DTI: 4 E1 ports; MDT: 16 E1 ports
•Inter-module trunks : n*2M= n* 30 DT

Agenda
•Networking Mode
•Traffic Calculation

Traffic Calculation (1)
SM
Single Module
Formula: N
L*T
1*x%<N
T*T
2
N
L
: Subscribers
T
1
: Traffic per subscriber
N
T
: Trunks
T
2
: Traffic per trunk
X: percentage of out-going calls
Example:
How many trunks are needed for
an office which has 5000 lines a
nd 80% calls are out-going calls?
In addition, the traffic is 0.1 Erl
per line, 0.8 Erl per trunk?
Answer:
Trunks = 5000*0.1*0.8/0.8=500
E1s= ceiling( 500/30,1) =17

Traffic Calculation (2)
2. For PSM/RSM at the bottom
N
L
*T
1
+N
T
*T
2
< N
B
*T
3
N
L
: Subscribers
T
1
: Traffic per subscriber
N
D
: Trunks
T
2: Traffic per trunk
N
B
: Inter-module trunks
T
3
: Traffic per inter-module trunk =1
3. For PSM/RSM in the middle
N
L
*T
1
+N
T
*T
2
+ ∑SM
i
< N
B
*T
3
N
L
: Subscribers
T
1
: Traffic per subscriber
N
D
: Trunks
T
2
: Traffic per trunk
N
B
: Inter-module trunks
T
3
: Traffic per inter-module trunk =1
SM: the traffic of the lower-level module, i=1,2,3…
CM
SM SM
SM
SM
DTI/ODTFBI
Multiple modules
SM
1. For office
N
L*T
1*X%<N
T*T
2
N
L
: Subscribers
T
1
: Traffic per subscriber
N
T
: Trunks
T
2
: Traffic per trunk
X: percentage of out-going calls

Example
A
C
E
B
D
Question:
There is a project including 5 sites. Accordi
ng to their geographical location, a 3-level n
etworking is proposed as shown in the pictu
re. The capacity of each sites are:
Site A: 5000L
Site B: 3000L plus 20 E1 trunks for inter-o
ffice connection
Site C, D: each having 2000L.
Site E: 800L
Traffic: 0.1Erl per line; 0.8Erl per inter-offic
e trunk; 1 Erl per inter-module trunks
70% calls are out-going calls
Plz, calculate how many inter-office trunks a
re increased in site A and how many inter-m
odule trunks are needed between modules.
Answer:
1. Total inter-office trunks = (5000+3000+2*2000+800)*0.1/0.8*70%/3
0 = 1120/30 =38 E1
So, another 38-20=18 E1 should be increased in site A for inter-office co
nnection.
2. Inter-module trunk between A and C, D and B
Trunks = 2000*0.1/1=200
So, 1 ODT or 7 E1 are used
3. Inter-module trunk between E and B
Trunks = 800*0.1/1=80
So, 1 ODT or 3 E1 are used
3. Inter-module trunk between B and A
Traffic of B = 3000*0.1+20*30*0.8= 780 Erl
Inter-module trunks = (780+200+80)/1 = 1060
So, 1 pairs of FBI are selected

SM4I
•Application
–Only used in single-module networking
•Typical configuration
•Subs. + trunks: 720L+720DT

SM4C
•Application
–Used in single-module networking
–Used as RSM in multi-module networking
•Typical configuration
–In single-module networking
•Single rack: 2400L+600DT
•Two racks: 5280L+600DT
–As RSM in multi-module networking
•Subs.+ trunks:

SM8
•Application
–Used in single-module networking
–Used as PSM/RSM in multi-module networking
•Typical configuration
–In single-module networking
•Subs.+ trunks: 12480L + 2760DT
•Only trunks: 6240DT
–As PSM/RSM in multi-module networking
•Subs.+ trunks:
•Only trunks:

SM16
•Application
–Used in single-module networking
–Used as PSM/RSM in multi-module networking
•Typical configuration
–In single-module networking
•Subs. + trunks: 15360L + 9600DT
•Only trunks: 14400 DT or 7 STM-1
–As PSM/RSM in multi-module networking
•Only trunks:

Multi-module Networking
Model Capacity
Lines/Trunks
CM256 1,000K/250K
CM128 800K/120K
CM64 605K/60K
CM32 298K/30K
SM16 148K/14K
SM8 70K/7K

Model Selection
•The capacity of office: 12800 Lines + 1120DT
•Site B: 3K lines + 600DT(Inter-office) + 280DT (Inter-
module)
•Site C, D: 2K lines + 200DT (Inter-module)
•Site E: 800 lines + 80 DT (Inter-module)
If the future expansion is not considered in this project, the
equipment model for each site is:
Site A: SM8
Site B: SM8
Site C, D: SM4C
Site E: SU960/SU960N

A Complete Configuration
•Equipments
•Software
•O&A computers
•MDF, DDF, Rectifier, Battery
•Summary