The setup is created as shown.
Work Path A – B
Protect Path A – C – B
MPLS Labels for the Forward and Reverse path on work and protect are planned as shown.
Configure Switch MAC address.
Enable MPLS on all the NNI ports.
Test Setup
A
00:00:00:01:05:53
IN:14000 IN:15000
OUT:15000 OUT:14000
IN:16000
OUT:34000
IN:33000
OUT:16000
IN:34000
OUT:15000
IN:15000
OUT:33000
UNI UNI
B
00:00:00:01:05:54
C
00:00:00:01:05:55
1-1 1-1
1-2
1-2
1-3 1-4
Maintenance Domain Level: 1 to7 (select any one, should be unique across the MEP)
MDName Format :Character String
MD Name : User defined name
Click on Create
Maintenance Domain Level: 1 to7 (select any one, should be unique across the MEP)
MDName Format :Character String
MD Name : User defined name
Click on Create
Tunnel Group (TG1) : A – B Work Path (TG1-Work)
A – C – B Protect Path (TG1-Protect)
Tunnel Group (TG2) : A – B Work Path (TG2-Work)
A – D – B Protect Path (TG2-Protect)
Protected Pseudo Wire Service
A
C
D
B
UNI
UNI
TG1-Work
TG2-Work