cconfined space.onfined space. confined space.ppt

ahmedsidahmed6 28 views 27 slides Sep 18, 2024
Slide 1
Slide 1 of 27
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27

About This Presentation

Confined


Slide Content

1
Confined Space
Module 9

2
DISCLAIMER
This material was produced under grant
number SH-22248-1 from the Occupational
Safety and Health Administration, U.S.
Department of Labor. It does not
necessarily reflect the views or policies of
the U.S. Department of Labor, nor does
mention of trade names, commercial
products, or organizations imply
endorsement by the U.S. Government.

3
Objectives
•After this module you should be able to
–identify the most common confined space
hazards
–take the necessary steps to avoid those
hazards

4
What is a Confined Space?
•A confined space is a space that
–is large enough for a person to enter and
work
–has limited or restricted means of entry and
exit
–is not designed for continuous occupancy

5
Permit-Required Confined Space
•A permit-required confined space has at
least one of the following characteristics
–contains or has the potential to contain a
hazardous atmosphere
–contains a material that has the potential to
engulf an entrant
–has an internal configuration such that an
entrant could be trapped or asphyxiated
–contains any other recognized serious safety
and health hazard

6
Confined Space Hazards
•Oxygen deficiency
•Flammable/combustible gases and vapors
•Toxic gases
•Engulfment in solid or liquid
•High noise levels
•Grinding, crushing, or mixing mechanisms
•Configuration
•Extreme temperatures
•Chemicals
•Lack of lighting

7
this is one example of a permit-
required confined space
always follow your company’s permit procedures,
even if you are going in for just a second

8
this confined space may be oxygen deficient or
contain flammable, combustible, or toxic gases or
vapors
test the atmosphere in this order: oxygen content,
then flammables, then toxics, then other hazards

9
test the atmosphere at all levels of the confined space; good
air near the opening doesn’t mean good air at the bottom
Good Air
Deadly Air

10
the atmosphere inside a confined
space may not be suitable for entry
forced-air ventilation may be used, but you are not
permitted to enter until the atmosphere is suitable

11
atmospheric conditions may change
while you are in the confined space
periodically monitor the atmosphere
within the confined space

12
Get Out!
•If a hazardous atmosphere is detected
while a worker is in the confined space
–all activities should stop
–the worker(s) should exit immediately
–the hazard should be evaluated
–protective measures should be taken

13
if a worker must wear a respirator, remember that an air-
purifying respirator will do nothing in an oxygen deficient
atmosphere
these workers are wearing air-supplying
respirators due to a lack of oxygen

14
adequate illumination should be
provided where lighting is limited
in some cases, explosion-proof
lighting may be necessary

15
some confined spaces can contain mixing or crushing mechanisms
or other hazards that can be turned on and injure a worker
use lockout/tagout on all hazardous items

16
Duties of Attendants
•Knows the hazards
•Maintains an accurate count of entrants
•Remains outside the permit space until
relieved by another attendant
•Maintains regular communication with
entrants
•Monitors conditions inside and outside of
the permit space

17
Duties of Attendants
•Summon rescue services when needed
•Ensures unauthorized personnel do not
enter permit space or affect operations
•Performs non-entry rescues
•Performs no other duties that might
interfere with primary duty to monitor
and protect the entrant(s)

18
it is possible for a worker to be overcome by
a sudden change in atmospheric conditions
ensure that a rescue procedure is in place in case an entrant
needs to be removed from a confined space in an emergency

19
the reserve pit is a permit-required confined space because of its
potential to contain a hazardous atmosphere and to drown a worker

20
Additional Concerns
•Noise
–amplified due to acoustics of the space
–damages hearing and affects communication
•Slippery or wet surfaces
–increased risk of falls and electrical shock
•Personal protective equipment
–more common ppe such as hard hat, hard-
toed boots, safety glasses, face shield, gloves,
and overalls must be worn when needed
•Hot work

21
Applicable Standards
•1910.146 Permit-Required Confined
Spaces

22
Your Employer Is Responsible For
•Providing atmospheric testing equipment
•If necessary, providing ventilation
equipment and/or respiratory protection
•Providing and training on confined space
permits and the written program
•Developing and training on emergency
action and rescue plans

23
You Are Responsible For
•Testing the atmosphere prior to entry
•Periodically monitoring the atmosphere
for possible changes
•Following permit procedures
•Ensuring that there is at least one
authorized attendant present at all times

24
Case Study
An employee climbed inside a tank to
unclog a line but did not test the tank’s
atmosphere. The tool he was using
produced a spark that ignited the
atmosphere.

25
Always Remember
•Test the atmosphere prior to entry and
periodically
•Never enter a confined space if the
atmospheric conditions are not suitable
•Ensure an attendant is outside the
confined space at all times
•Follow your company’s confined space
permit

26
Memory Check
1.What is the correct order of atmospheric
testing?
a.flammables, toxics, oxygen, other
b.toxics, oxygen, flammables, other
c.oxygen, toxics, flammables, other
d.oxygen, flammables, toxics, other

27
Memory Check
2.A space that meets the definition of a
confined space and contains other
recognized serious safety and health
hazards is what?
a.a confined space
b.a permit-required confined space
c.a non-permit-required confined space
d.not a confined space