1517.04 Lift cylinder pressure sensor voltage low (below 0.24 V).2
1518.02 Circuit codes 436, 487, 488, and 489 changed while the
Automatic Header Control system was in the automatic mode.
These are the header select lines that identify the type of header
on the combine.
3
1518.07 Header not connected or invalid connection. Circuit codes 436,
487, 488, and 489 are the header select lines that identify the type
of header on the combine.
3
1518.14 Cannot activate Header Height Sensor or Automatic Header
Control. Header sensors are not available.
3
1519.11 Header raise valve driver detects an open, short, over voltage, or
over temperature condition. The Header Control Unit will not
actuate the Header Raise Valve until the fault condition is
removed.
2
1520.11 Header lower valve driver detects an open, short, over voltage, or
over temperature condition. The Header Control Unit will not
actuate the Header Lower Valve until the fault condition is
removed.
2
1521.11 Tilt left valve driver detects an open, short, over voltage, or over
temperature condition. The Header Control Unit will not actuate
the Tilt Left Valve until the fault condition is removed.
2
1522.11 Tilt right valve driver detects an open, short, over voltage, or over
temperature condition. The Header Control Unit will not actuate
the Tilt Right Valve until the fault condition is removed.
2
1524.11 Reel Forward valve driver detects an open, short, over voltage, or
over temperature condition. The Header Control Unit will not
actuate the Reel Forward Valve until the fault condition is
removed.
3
AG,OUZXMAY,227 -19-17FEB00-6/8
1525.11 Reel aft valve driver detects an open, short, over voltage, or over
temperature condition. The Header Control Unit will not actuate
the Reel Aft Valve until the fault condition is removed.
3
1526.11 Reel raise valve driver detects an open, short, over voltage, or
over temperature condition. The Header Control Unit will not
actuate the Reel Raise Valve until the fault condition is removed.
3
1527.11 Reel lower valve driver detects an open, short, over voltage, or
over temperature condition. The Header Control Unit will not
actuate the Reel Lower Valve until the fault condition is removed.
3
1529.11 Accumulator shutoff valve driver detects an open, short, over
voltage, or over temperature condition. The Header Control Unit
will not actuate the accumulator shutoff valve until the fault
condition is removed.
3