Comparison of hormonal assay

rijaa 1,693 views 42 slides Mar 21, 2016
Slide 1
Slide 1 of 42
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42

About This Presentation

Comparison of hormonal assay �by �ELISA , ELFA , and ECL
Methods .


Slide Content

Comparison of hormonal assay by ELISA , ELFA , and ECL Methods أعداد الكيمياويه رجاء عبود

Introduction Hormone measurement is necessary for the diagnosis of a wide range of clinical conditions and is essential for monitoring the effectiveness of treatment. As the number of hormone requests in the clinical field rises exponentially, it has become importance to create hormone assays accessible to researchers with a different range of devices.

Before the introduction of radioimmunoassay most hormones were measured by bioassay and/or chemical methods. The sensitivity of these methods was low, and large amounts of samples were needed . Radioimmunoassay first applied In 1959, to measurement of insulin, after which many protein hormones were determined by this method.

Because radioactivity poses a potential health threat, so Research had to be go on for finding a safer alternative . The first paper on the ELISA procedure published in 1971 as a replacement for radioimmunoassays by Sweden and Netherlands Scientists independently .

Recently, non-isotopic immunoassay methods utilizing chemiluminescence , fluorescence and enzymes as labels are widely used. These methods have resulted in sensitivities adequate to replace radioimmunoassays.

Important components in immunoassay 1-Antibody (antiserum ) . 2-Antigen . 3-Labeling materials .

1-Antibody (antiserum) proteins produced by the immune system which help defend against antigens . The variable regions are though to be the place for recognition and binding with the antigen.

2-Antigen Any molecule that induces production of antibodies when introduced in the body is called antigen.

3-Labeling materials In immunoassay, it is necessary to use any marker to know the antigen-antibody binding. For such purpose, they label either antigen or antibody with some materials that do not interefere with the binding.

ELISA Why known as……………?? E nzyme- L inked I mmuno S orbent A ssay

1 . Antigen/antibody of interest is absorbed on to plastic surface (‘sorbent’). 2 . Antigen is recognised by specific antibody (‘immuno’). 3 . This antibody is recognised by second antibody (‘immuno’) which has enzyme attached (‘enzyme-linked’). 4 . Substrate reacts with enzyme to produce product, usually coloured.

ELISA Is used to the detection of Antibodies . Proteins . Peptides . Biomolecules .

Basic principal of ELISA ELISAs can provide a useful measurement of antigen or antibody concentration . A general ELISA is a five-step procedure : 1) coat the microtiter plate wells with antigen . 2 ) block all unbound sites to prevent false positive results . 3 ) add primary antibody to the wells .

4) add secondary antibody conjugated to an enzyme . 5) reaction of a substrate with the enzyme to produce a colored product, thus indicating a positive reaction.

There are five types of ELISA, but the of the most common types are : Direct ELISA Indirect ELISA . Sandwich ELISA . Competitive ELISA .

Competitive ELISA

ELFA (Enzyme Linked Fluorescent Assay )

Technology which is based on a one-step immunoassay sandwich method and a final fluorescent detection step . Two ready-to-use reagents . 1 - The SPR® S olid P hase R eceptacle serves as a solid phase and pipetting device. Coated with mouse monoclonal anti-human immunoglobulins.

2- The reagent strip contains pre-dispensed reagents : Conjugate: alkaline phosphatase- labelled mouse monoclonal anti-human immunoglobulin . Fluorescent substrate: 4-MUP (4-Methyl-umbelliferyl phosphate) & DEA (diethanolamine). Washing buffers .

1- Measuring Principle The reaction occurs within the interior of the SPR whereby antibodies and conjugate form a sandwich . (4-MUP) is cycled into SPR and conjugate enzyme catalyses the hydrolysis of the substrate into 4-Methyl-umbelliferone which is measured at 450nm.

The intesity of the Fluorescence is inversely proportional to the concentration of antigen present in the sample .

ECL Electrochemiluminescence

“ Electro” refers to electrical stimulation . + “ Chem ” indicates a chemical reaction. + “ Luminescence” means “produces light.” = Electrochemiluminescence (ECL)

Principle Electrochemiluminescence Chemiluminescence is light produced by a electrochemical reaction from a substance as it returns from an electronically excited state to ground state . The chemiluminescent substance is excited by the oxidation and catalysis forming intermediates. When the excited intermediates return back to their stable ground state, a photon is released, which is detected by the luminescent signal instrument .

An enzyme converts a substrate to a reaction product that emits photons of light instead of developing a visible color . ECL is a unique and highly sensitive luminescence (light) detection system that amplifies the signal (you want) to detect ultra-low concentrations of analyte. and reduces any signals you don’t want to deliver .

Source kicks an electron of an atom out of its lowest energy “ground” state into a higher energy “excited” state . Electron returns the energy in the form of light so it can fall back to its “ground” state . [A] + [B] → [◊] → [Products] + light [A], [B]: reactants [◊] : excited intermediate .

For example, if [A] is luminol and [B] is hydrogen peroxide in the presence of a suitable catalyst we have: luminol + H2O2 → 3-APA [◊] → 3-APA + light Where : 3-APA is 3-aminophthalate 3-APA[◊] is the excited state producing light as it return to a lower energy level.

What happens in Chemiluminescence immunoassays Monoclonal antibody coated well ↓ Test specimen (serum) ↓ HRP labelled antibody conjugate ↓ Test antigen: sandwich between solid phase Ab and enzyme labelled Ab

Incubate at 37° C ↓ Remove unbound enzyme labeled Ab ↓ Chemiluminescence reagent added ↓ Read relative light unit with luminometer

luminescence is the most sensitive detection method currently in use due to the ability of signal multiplication and amplification . Luminescent reactions are measured in relative light units (RLU) that are typically proportionate to the amount of analyte present in a sample.

Properties Ultra-high sensitivity (10, 000 times higher than and the light absorption method and 1000 times higher than the fluorescence detection method ) . Show a linear relationship between luminous intensity and the concentration of measured substance . N o preincubation step . Substrate can be added several minutes prior to detection.

A COMPARATIVE ANALYSIS ON THREE DIFFERENT FULLY AUTOMATED ANTI-TOXOPLASMA IGM IMMUNOASSAYS

Diagnoses acute toxoplasmosis during the first trimester of pregnancy . Sensitivity and specificity are calculated for each technique: ELISA technique showed a specificity of 83% and a sensitivity of 95%. ELFA technique showed a specificity of 90% and a sensitivity of 97.5%. ECL technique showed a specificity of 100% and a sensitivity of 100%.

Comparison Between Chemilluminescent Assay No stop solution Higher sensitivity No light source(Filter) ELISA Stop solution required (not in kinetic assay ) Less sensitive Light source needed