408 Index
Convert-to-BCD (TOD) instruction, 51, 53f, 235, 243, 243f
Conveyor warning signal circuit, 139f
COP. See File copy (COP) instruction
Cost, 2–3
Count-down (CTD) counter, 168, 168f
CLX system, 371–372f
Count-down (CD) enable bit, 160
Counter file, 75
Counter function, timer function and, 174–177
Counter number, 161
Counters, 82, 156–178
accumulated value, 158, 158f
application, 157f
block-formatted, 158, 158f
cascading counters, 170–172, 171f
CLX system, 368–372, 368f
combined with timer functions, 372, 372f
count-down (CTD) counter, 371–372f
count-up (CTU) counter, 369–370f, 369–371
overview, 368–369
coil-formatted, 157–158, 157f, 158f
combining with timer functions, 174–177, 175f
decrement, 158
down-counter, 166–169, 167f
electronic, 157, 157f
high-speed, 177–178, 178f
increment, 158
incremental encoder-counter applications, 173–174, 174f
input conditions, 158
instructions, 157–158
mechanical, 157, 157f
selection toolbar, 161f
up-counter, 159–166, 159f
Counting, high-speed, 4f
Count-up (CTU) counter
CLX system, 369–370f, 369–371
Count-up (CU) enable bit, 160
CPU section, processor module, 35
Cross reference function, 289, 290, 290f
Current sensing, 27
CV. See Control variable (CV)
D
DAC (digital-to-analog converter), 29, 94
Daisy-chain topology, 326, 327f
Data communications, 316–328. see also Network
communications
ControlNet, 325, 325f
Data Highway, 322, 322f
defined, 316
DeviceNet, 322–325, 323–324f
EtherNet/IP, 325, 326f
Fieldbus, 326, 327f
HART, 328, 328f
industrial networks, functionality levels, 318, 318f
LAN, 317–318, 317f
Modbus, 326, 326f
parallel data transmission, 321, 321f
point-to-point serial communications link, 317, 317f
PROFIBUS-DP, 326–327, 327f
SERCOS, 327, 328f
serial, 322, 322f
serial transmission, 321–322, 321f
transmission media, 317, 317f
Data comparison, 208, 216–221. See also Data
manipulation
EQU instruction, 217, 217f
GEQ instruction, 217, 218, 218f
GRT instruction, 217–218, 217f
LEQ instruction, 217, 218, 218f
LES instruction, 217, 218, 218f
LIM instruction, 217, 218–220, 219f, 220f
MEQ instruction, 217, 220–221, 220f, 221
NEQ instruction, 217, 217f
use, 216–217
vs. data transfer, 216
Data files, 75–78, 77–78f
Data File screens, RSLogix 500 software, 92, 92f
Data flow, scan process, 79, 79f
Data Highway, 322, 322f
Data latching, FBD, 387, 387f
Data manipulation
closed-loop control, 226–229
ladder logic addition to main routine, 348–350,
348–350f
ladder logic program, 346, 346f
latch and unlatch instructions, 352–353, 352–353f
one-shot instruction, 353–354, 354–355f
program scan, 345–346, 345f
tag-based addressing, 347–348, 347f
comparison instructions, 376–378, 377–379f
configuration, 334–335, 335f
counters, 368–372, 368f
combined with timer functions, 372, 372f
count-down (CTD) counter, 371–372f
count-up (CTU) counter, 369–370f, 369–371
overview, 368–369
FBD programming, 388–392, 388–393f
function block diagram (FBD), 384–387, 384–387f
add-On instructions, 384
Assume Data Available indicator marker, 387, 388f
BAND (Boolean AND) function block,
384–385, 385f
data latching, 387, 387f
feedback loop, 387, 387f
function blocks, 384
references, 385
signal flow and execution, 386–387, 386f
wire connectors, 385–386, 386f
wires and pins, 385, 386f
math, comparison, and move instructions, combining,
380–382, 380–382f
math instructions, 374–376, 374–376f
memory layout, 334, 334f
move instructions, 379, 380f
programs, 336–337, 337f
project, 335–336, 335–336f
routines, 337, 337f
structures, 340–341, 340–341f
tag-based addressing format, 19, 20f
tags, 337–340, 338–340f
creating, 341, 341f
monitoring and editing, 342, 342f
tasks, 336, 336f
timers, 358–366
cascading, 365, 366f
off-delay timer (TOF), 362–363, 362–363f
on-delay timer (TON), 359–362, 359–362f
predefined structure, 358–359, 358f
reciprocating, 365
retentive on-delay timer (RTO), 364–365,
364–365f
Control management PLC application, 13, 13f
ControlNet, 325, 325f
Control panel
PLC-based, 2, 3f
relay-based, 2, 3f
Control process
automatic, 121, 121f
combination, 121, 121f
sequential, 121, 121f
flow diagram, 121–122, 121f
I/O connection diagram, 122, 122f
ladder logic program for, 122, 123f
relay schematic for, 122, 122f
Control relays (CR)
coils, 100
contacts, 100
electromagnetic, 99–100, 99–100f
internal, 89
operation, 99, 99f
pilot lights control operation, 99–100, 100f
symbol, 99, 100f
Control systems. see also Process control; Process(es)
actuators, 308
closed-loop, 309, 309f
controllers, 308–310
distributive, 307, 308f
HMI, 308
motion control, 315–316
on/off control, 310–311, 310–311f
PID control, 311–315
sensors, 308
signal conditioning, 308
structure, 308–310
Control variable (CV), 229
Convert from BCD (FRD) instruction, 235, 243, 243f
Channels per module, analog I/O modules, 34
Circuits. see also specific types
electrical interlocking, 115–116, 115–116f
seal-in, 114–115, 114–115f
Circulating shift register function, 265
Clear (CLR) instruction, 243
Closed architecture, 4
Closed-loop control system, 226–229, 309–310, 309f
block diagram of, 227, 228f
Closed-loop servo motor system, 114, 114f
CLR (Clear), 208
CMOS-RAM chips, 38, 38f
Coaxial cable, 317, 317f
Codes. see Number systems and codes
Coil-formatted counter instruction
up-counter, 157–158, 157f, 158f
Coil-formatted timer instruction, 134–135, 135f
Cold junction compensating (CJC) thermistor, 27
Collision detection access control scheme., 320
Combination control process, 121, 121f
Combination I/O modules, 21–22, 21f
Commissioning, 288
Common Industrial Protocol (CIP), 323–324, 325
Common-mode rejection, analog I/O modules, 34–35
Communication module, 4f, 18, 32, 33f
Communications capability, 3, 4f
Communications protocol, 300
Commutative law, 65
CompactLogix system, 333
Compare menu tab, 217, 217f
Comparison instruction, CLX system, 376–378, 377–379f,
380–382, 380–382f
Compute instruction, 235–236, 235f
Compute/Math menu tab, 235, 235f
Computer memory, 48, 49f
Computers, vs. PLCs, 11–12, 11–12f
Configuration, CLX system, 334–335, 335f
Consecutive group, 208
Constant voltage (CV) transformer, 287
Contact histogram function, 290–291
Contact instruction, 85
Contactors, 100, 101f
Contacts
control relays, 100
instantaneous, 132
normally closed (NC), 99, 100f
normally open (NO), 99, 100f
Container-filling process, 310f
Continuous process, 306, 306f
Continuous-scan test mode, 93
Continuous tasks, 336
Continuous test mode, 289
Control, FAL instruction, 212
Control circuit, 100
Control devices, output, 112–113f, 112–114
Control file, 75
Controllers, 308–310. see also specific types
deadband, 311, 311f
proportional, 311–315, 311f
Controller tag, 338
ControlLogix 5000
BSL instruction, 271–272, 272f
BSR instruction, 271
counter instructions, 162, 163f
FIFO instruction pair, 275–276, 276f
immediate output instruction, 194, 194f
memory structure, 75
Modulo (MOD) instruction, 242, 242f
pass/fail inspection program, 271–272, 272f
platform, 48
program, 220, 220f
timer instruction, 136–137, 136f
ControlLogix Sequencer Output (SQO) instruction,
258–259, 259f, 260f
array, 259
control, 259
destination, 259
length, 259
mask, 259
position, 259
ControlLogix (CLX) system, 334–393
array, 342–343, 343f
bit-level programming, 345–355
internal relay instructions, 350–352, 351–352f
pet73842_ind_407-414.indd 408 03/11/15 4:11 PM