The common lawn shared by La and BM_BT dept is a good interactive space and the trees and landscaping provides good microclimate for both the building. But during high peak of the day its not been used, so proper landscaping with shades can be provided over there. The lawn in front of library with the tea stall(very good interactive space) , it even has rose garden and some deciduous trees. The gardens between main building and the mechanical department creates a buffer between both the blocks yet it keeps a visual connectivity. The trees around NCC ground provides aesthetics and shade to the main building but not for reducing noise and smoke. The green spaces helps to decrease the surrounding temperature . The courtyard in all the dept can be properly maintained and landscaped to make it much more interactive Seating can be placed in the common spaces Rows of trees can be there at the side of the road to provide shade and also a linear vista INFERENCE
Analysis in micro level
Computer science department FIRST FLOOR PLAN
Computer science department SECOND FLOOR PLAN THIRD FLOOR PLAN
Inference ( cs dept ) CLIMATE: day light blocked by trees CLIMATE: double facade is present CLIMATE: no trees on south side BYELAWS : ramp is there on the east side for differently able people BYELAWS: fire safety plan required AREA: area for individual room is of standard FUNCTION : The distance between the two staircase is more than 40mts FUNCTION : the space behind the new lab is of no use FUNCTION :Courtyard not properly in use FUNCTION: toilet on SW acts as a buffer zone FUNCTION: we can have basement for earth bumping FUNCTION: can have a coffee shop behind the window for more interaction FUNCTION: courtyard need to be made much more interactive PROXIMITY: this dept is in proximity with EC-EI dept. POXIMITY: canteen, stationary shop and SAC is in proximity ECOLOGY: trees are there in north side and in front it is been landscaped a bit
MINING DEPARTMENT GROUND FLOOR PLAN
MINING DEPARTMENT FIRST FLOOR PLAN SECOND FLOOR PLAN
Inference ( mn dept ) CLIMATE: Trees on the side provides cool micro climate inside BYE-LAWS : No fire escape staircase and not designed for differently able person BYELAWS: Circulation space=35%, but must be 30% AREA: 375 students and 4 classroom for that not sufficient AREA: Wide corridor of 3.6mts AREA: staircase with no external wall AREA: Research lab more spaces (good) but labs where chemicals are used or computer lab are having less space FUNCTION: Parking share by ceramic department FUNCTION: Faculty room in front has no proper ventilation. FUNCTION : Columns are place badly, so they can be sifted for utilization of spaces FUNCTION: No plinth in front, reptiles can enter FUNCTION: Courtyard not properly utilized, mainly used for drainage purpose and for sampling lab FUNCTION:Total 3 entrances, 2 on the side are not utilized and remain close FUNCTION:Courtyard accessed from only one path FUNCTION:Double loaded corridor with no proper ventilation PROXIMITY: with architecture and ceramic department ECOLOGY : trees- sal , ashoka
Main building GROUND FLOOR PLAN
Main building FIRST FLOOR PLAN
Main building SECOND FLOOR PLAN
Main building THIRD FLOOR PLAN
INFERENCE (MAIN BUILDING) CLIMATE:Trees in front of the main building is just for aesthetics and not for controlling the wind and smoke CLIMATE:The fins in the window are not enough to protect the rooms from sunlight BYELAWS:The staircase can act as a fire shaft BYE-LAWS: no fire safety escape BYELAWS: not for differntky able people AREA:Open spaces=40% and circulation= 30% AREA:Width of corridor not constant in all the places AREA: Huge classroom broken down to create partition AREA:It has metallurgy, civil, physics, chemistry, mathematics and life science department AREA: the room and labs are following the standard, but the civil labs are too much congested FUNCTION:Stage is there in front of the courtyard FUNCTION : Linear vista through the main gate FUNCTION:4 access way- main gate, mangla mandir , CR dept and EC dept FUNCTION: Double loaded corridor thus no proper light and ventilation FUNCTION:AC vents run all through the corridor FUNCTION:Courtyard not used for interactive space FUNCTION:The newly constructed courtyard used by the professor as the smoking zone FUNCTION:All the corridor is facing inside, good design from wind point of view PROXIMITY: The individual labs and there classroom are not in proximity with each other ECOLOGY:Right side of main building have tress mainly- ashoka , neem tree ECOLOGY:Banayan tress at the side a great interactive space
library GROUND FLOOR PLAN
library FIRST FLOOR PLAN
library SECOND FLOOR PLAN
Inference (library) CLIMATE: should have proper lighting in the interior CLIMATE : Humidity needs to be controlled as there is book stalking- Double Humidifiers BYELAWS: No fire escape staircase is there BYELAWS: not for differently able people, but lift is there AREA: no sufficient num of toilets. Toilet for females only in ground floor. AREA: the area is sufficiently but need proper arrangement AREA: entrance and baggage counter, reception, book issue counter need more space FUNCTION: Control rooms in all the floor. FUNCTION: AC control room till G+1. FUNCTION : G+1 acts as a b ehaviour room and students are restricted. FUNCTION : We need an interactive entrance, much informal one FUNCTION: We can have a museum with it, we can display over there about the things made in the college campus like Digital display & Art room. FUNCTION: Spaces which doesn’t require a control environment can be the clock room . FUNCTION : Stacking and reading space needs AC PROXIMITY: with architecture and main building ECOLOGY: green lawn present in front which is a good interactive space
Bm-bt department GROUND FLOOR PLAN FIRST FLOOR PLAN
Bm-bt department SECOND FLOOR PLAN THIRD FLOOR PLAN
Inference ( Bm-bt department) 2 entrances No fire exit. Travel distance is more than 40mts metres between 2 staircase. 540 is the present students capacity. It can accommodate more people around 900 students. So used for extension of building. Ramp 1:10 ratio, thus it couldn’t be used by wheel chairs. Courtyard not properly utilized. I t doesn’t properly gives ventilation in the upper floor Casement windows (bad), so no cross ventilation but for humidity it remains cool inside. Presently, single loaded corridor is there. Double loaded corridor can be there, as gaps in the middle can be utilized as interactive space. North side is the classroom which is very good Recessed windows are there with thick wall, which is good as thermal mass. Thus provide cool interior Because of the plantation in front of the dept , it keeps the inside cool Universal design
workshop GROUND FLOOR PLAN
Inference (workshop) CLIMATE: The plan is made such, that it provides ventilation & light in the interior. BYELAWS- no fire safety norms BYELAWS: no plinth so differently able people can access AREA: electrical, carpentary and machine lab is fine. Welding lab need more space as clubs also work there. AREA: Per workshop departments 25 students. FUNCTION: The plan is a very simple one , we need to understand the user profile. FUNCTION: Machine shop too heavy, so need more maintenance. Big iron pieces used in the machine shop are cut in the welding shop. FUNCTION: The middle space is used as courtyard, but not properly maintained. FUNCTION : No plinth is there. They can have a separate entrance from where the model of cars can be taken out. FUNCTION : No chair is there inside, otherwise students will sit. FUNCTION: Should look at the building as a modular system PROXIMITY: with mechanical and chemical dept ECOLOGY:Palm trees are in front.
Mechanical department ACADEMIC BLOCK GROUND FLOOR PLAN FIRST FLOOR PLAN
Mechanical department WORKSHOP BLOCK GROUND FLOOR PLAN
Mechanical department WORKSHOP BLOCK FIRST FLOOR PLAN
INFERENCE (Mechanical department) CLIMATE: needs proper ventilation and light, as it is worked with machines BYELAWS : No fire safety. Only one staircase is there to exit from the 1st floor. BYELAWS: not for differently able people AREA: Small room for the labs at the front side of building. AREA: Faculty rooms are very large with 1 faculty and 3 PhD scholars working. FUNCTION: Garage type door to facilitate large machines – large machine lab. FUNCTION: 1 faculty lab not getting any ventilation. FUNCTION: Production design lab is having double height , for the fumes need more space to escape. FUNCTION : Planning or landscaping required in big courtyard for interaction FUNCTION: Many courtyards are used as stores FUNCTION: some rooms which doesn’t requires light, can be places in the interior. Eg : xray room PROXIMITY: with central workshop and PPA. In front of it is the nescafe ECOLOGY : Ashoka tree in front.
Chemical department
Chemical department
Chemical department INFERENCE CLIMATE: a lot of glazing is put on the side which is getting the direct sunrays. CLIMATE: AC is required for the professors room west BYELAWS: The staircase in South, may act as fire escape staircase. BYELAWS: Not for differently able people AREA: The labs are huge, but they are not properly ventilated FUNCTION : Unique in appearance. FUNCTION: The staircase in the rare end is only till G+1, not in the upper blocks FUNCTION: Mostly labs are here in the department. FUNCTION: The south part is till G+3. FUNCTION: G+1 helps in ventilation in G+3. FUNCTION: The courtyard is covered up so heat doesn’t goes up, but because of the trees in front of the dept. , it provides good cool microclimate inside FUNCTION: Most classes are taken in L.A. PROXIMITY: food and chemical department are together PROXIMITY: With BMBT department ECOLOGY: south side is shaded by trees.
Lecture academy
Lecture academy
Lecture academy INFERENCE : FUNCTION: The common classes must be linked with all the departments FUNCTION: For a bigger room in LA, create much more interaction by having projectors in the class FUNCTION: Should have acoustical treatment Lift should be with a lift room FUNCTION: Courtyard is stepped, so can be made much more interacting and interesting Courtyard can have a water element to provide a good micro climate, but pump it out during the humid months FUNCTION: Should have formal and informal interactive spaces FUNCTION: Furniture layout can be much more interesting No proper fenestration thus keeping the classroom hot and humid FUNCTION: A double heighted lobby space
Ceramic department
Ceramic department INFERENCE : Staircase very far away from each other. Dead end dist more than 6mts FUNCTION: Rooms are placed in such a way that spaces are there in-between the rooms to provide light and ventilation Landing is not according to bye-laws in the front portion Labs and professors cabin are in proximity so more interacting No landing before the door in front of the ramp FUNCTION: Store spaces adjacent to the lab is interesting Faculty rom blocking the path of the corridor Toilet space is vey less FUNCTION: The space in between the faculty room is empty and is not of any use FUNCTION: All the office block is in the ground floor- good FUNCTION: Eggcrate fenestration is good for the building FUNCTION: Corridor in the south act as a buffer zone
ppa GROUND FLOOR PLAN FIRST FLOOR PLAN
INFERENCE (PPA) FUNCTION: Entrance is not properly designed FUNCTION: This building can act as a good interactive space, which is not there presently FUNCTION: We can provide a stage for much more interaction PROXIMITY: should be in proximity with BBA AREA: no proper seating space
PLANNING AND ARCHITECTURE GROUND FLOOR PLAN
PLANNING AND ARCHITECTURE FIRST FLOOR PLAN INFERENCE : FUNCTION: No plinth in front FUNCTION: Previously was a high voltage lab turned to architecture dept. FUNCTION: Office connected with HOD room thus no privacy FUNCTION: 2 part of computer room, thus miscommunication between the students and teacher sometime FUNCTION: Library not accessed from the corridor, and its very small in size CLIMATE: Ground floor is cool but humid FUNCTION: Faculty room no ventilation FUNCTION: Kitchenate can be there as people stay whole night FUNCTION: The classroom in upper floor should be big enough FUNCTION: Exhibition gallery, lockers, loungh should be there and must be made more interesting and interactive PROXIMITY: in proximity with library,main building and mining dept. but should be close to civil dept CLIMATE: bad plan as the longest side is facing east and west
EC-EI DEPARTMENT GROUND FLOOR PLAN
EC-EI DEPARTMENT FIRST FLOOR PLAN
EC-EI DEPARTMENT SECOND AND THIRD FLOOR PLAN
INFERENCE ( EC-EI DEPARTMENT) FUNCTION: Double loaded corridor is fine as there is proper ventilation and lighting FUNCTION: Functionally the plan is fine FUNCTION: Basement cant be used as earth bumping but with proper water proofing The building is inclines at an angle of 27 degree from the normal FUNCTION: Proper ventilation to the courtyard is there, but its of no use as the top floor are having all glazing FUNCTION: Entrance height is double, so in summer sun rays are restricted while in winter the rays enter inside FUNCTION: Corner space have balcony from G+2 FUNCTION: The whole building is symmetrical with the addition of high voltage lab in the electrical section BYELAWS: Universal design FUNCTION: Courtyard gets heated up as its fully cladded with tiles