Degradation Analysis Using LC-MS/MS

802 views 41 slides Aug 16, 2017
Slide 1
Slide 1 of 41
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41

About This Presentation

use for instrumental Analytical method of separation.


Slide Content

Degradation Analysis Using LC-MS/MS 1 Presented By:- Mr. Sachin R. Naksakhare M.Pharm Sem-III Guided By:- Dr. R. P. Bhole Dr. D .Y Patil Institute Of Pharmaceutical Science and Research, Pimpri, Pune

CONTENTS: Degradation Analysis Hyphenated technique Introduction of LC Introduction of MS Introduction of LC-MS Interfaces used in LC-MS Mass Analysers Applications Case study Conclusion References 2

1. Degradation Analysis To help to identify reactions that cause degradation of pharmaceutical product. The stability of a drug product or a drug substance is a critical parameter which may affect purity , potency and safety . Changes in drug stability can risk patient safety by formation of a toxic degradation products or deliver a lower dose than expected. Knowledge of the stability of molecule helps in selecting proper formulation and packaging. The various type of Degradation 1. Hydrolysis [Acidic, Alkaline and Neutral] 2. Oxidation 3. Photolytic 4. Thermal 3

This two Guideline are used for stability testing:- ICH Q1A(R2) [Stability Testing of New Drug Substances and Products] ICH Q1B [Photostability Testing of New Active Substances and Medicinal Products] Degradation studies are carried out for the following reasons: To solve stability-related problems. To generate more stable formulation. To identify impurities related to drug substances. To develop and validate a stability indicating method. To determine degradation pathways of drug substances and drug products. 4

STRESS CONDITION EXAMPLES DRUG SUBSTANCE DRUG PRODUCT PRODUCT PLACEBO ACID/BASE 0.01 to 0.1N few hours to 7 days 1- 2 days 1-2 days OXIDATIVE 0.3-3% H2O2 few hours to 7 days 1- 2 days 1-2 days PHOTOLYTIC 1200 Lux h > 48h > 48h > 48h THERMAL TESTING 10ºC to 70ºC up to 2 weeks up to 3 weeks up to 3 weeks TEMPERATURE / HUMIDITY 10ºC to 70ºC and 60 to 80 % RH up to 2 weeks up to 3 weeks up to 3 weeks TABLE 1: TYPICAL STRESS STUDY DESIGN

2. Hyphenated technique The term “ hyphenation ” was first adapted by Hirschfeld in 1980 . The hyphenated technique is combination or coupling of two different analytical techniques with the help of proper interface. To obtain a faster and more appropriate analytical tool. It may involve coupling of Chromatographic tech. with Spectroscopic tech. Eg . LC-MS, GC-MS, LC-MS/MS, GC-MS/MS, LC-FTIR, LC-IR, CE-MS, LC-NMR. 6

3. Introduction of LC Chromatography is first invented by Mikhail Tswett , a botanist in 1906 . Liquid chromatography is type of chromatography in which analyte molecule get partition between moving mobile phase and stationary phase . LC is the most widely used in the analytical separation techniques. In liquid chromatography includes following techniques:- 1. Partition chromatography, 2. Adsorption chromatography, 3. Ion-exchange chromatography, 4. Size-exclusion chromatography, 5. Affinity chromatography, 6. Chiral chromatography. 7

8 Schematic diagram of Liquid chromatography

4. Introduction of MS Mass spectroscopy (MS) is an analytical technique used to measure the mass-to-charge (m/z) ratio of ions. Used to find the composition of a physical sample by generating a mass spectrum representing the masses of sample components. All mass spectrometers consist of three basic parts: Ion source , Mass analyzer , and Detector system . 9

Schematic diagram of mass spectroscopy 10

5. Introduction of LC-MS LC-MS is an analytical chemistry technique that combines the physical separation capabilities of LC with the mass analysis capabilities of MS . LC-MS in recent years, has become one of the most powerful analytical techniques for qualitative and quantitative analysis. LC separates the sample components and then introduces them to the mass spectrometer. MS creates and detects charged ions. The LC/MS data may be used to provide information about the molecular weight, structure, identity and quantity of specific sample components. 11

Instrumentation of LC-MS 1)HPLC Part: 1. Solvent reservoirs 2. Pumps 3. Sample injector 4. Column 5. Detector 6. Data system 2) Mass spectrometer Part: 1. Ion Sources a. Electrospray ionization (ESI), b. Atmospheric pressure chemical ionization (APCI), c. Atmospheric pressure photo-ionization (APPI). 12

2. Mass Analysers 1) Time-of-flight 2) Quadrupole 3) Quadrupole Ion trap 3. Detector 4. Data system 13

Advantages of LC-MS High sensitivity. High selectivity. Multi-component simultaneous analysis. Accurate qualitative and quantitative analysis 14

6. Interfaces used in LC-MS The currently, the most common LC-MS interfaces are:- 1. Electrospray ionization (ESI), 2. Atmospheric pressure chemical ionization (APCI), 3. Atmospheric pressure photo-ionization (APPI). 15

6.1 Electrospray ionization (ESI) MS using ESI is called (ESI-MS) or (ES-MS). ESI is also called 'soft ionization' technique, since there is very little fragmentation. Electrospray ionization is the ion source of choice to couple LC with MS. ESI is a technique used in MS to produce ions using an electrospray in which a high voltage is applied to a liquid to create an aerosol. 16

17 Diagram of Electrospray Ionization . Taylor Cone emits a jet of liquid drops Solvent from the droplets progressively evaporates, leaving them more and more charged Charge exceeds the Rayleigh limit the droplet explosively dissociates, leaving a stream of charged ions

Advantages:- Higher MW possible due to multiple charges. Provides good sensitivity. Can be used for volatiles, non-volatiles and polar compounds. Easy to Operate. Flow rate up to 1ml/min. Disadvantages:- It is very little structural information can be gained from the simple MS. Need Solubility in Polar Solvent. 18

6.2 Atmospheric pressure chemical ionization (APCI) APCI usually consists of three main parts: Nebulizer probe ,  ionization region and ion-transfer region . The chemical ionization process where the solvent acts as the CI reagent gas to ionize the sample. The LC eluate into a nebulizer with a flow rate 0.2-2.0mL/min. Mobile phase and analyte are first nebulized (N2) and vapourised by heating to 120 C . The resulting vapour is ionized using a corona discharge needles. Subsequent ion/molecule reactions then cause ionization of the analyte. 19

Diagram of APCI 20

Advantages:- Easy to use. High flow rates (0.2- 2ml/min). Works with water. It is higher sensitivity than ESI. The analysis of volatile and semi-volatile molecules. Interface to HPLC. Disadvantages:- Not analysis of non-polar molecules. Need Thermal Stability . 21

6.3 Atmospheric pressure photo-ionization (APPI) In this technique, UV light  photons  are used to ionize sample molecules. The APPI method in high sensitivity ionization of both nonpolar and low-polarity compounds.   They are exposed to the UV light, the analyte molecules are ionized in two ways 1. Direct APPI :- M + h ν   ⇨   M +•   +  e - 2. Dopant APPI :- D +•    +   M   ⇨   M +•    +   D Dopant e.g.:- Toluene, Acetone, Anisole and Chlorobenzene. 22

Diagram of APPI 23

Advantages:- APPI can analyze both nonpolar and low-polarity compounds. High enough to ionize the target molecules. Interface to HPLC. Disadvantages:- Flow rate 0.1ml/min. Need Volatile Sample. Need Thermal Stability. 24

7. Mass Analyzers A mass analyzer is the component of the mass spectrometer that takes ionized masses and separates according to their mass-to-charge (m/z) ratios of ions. The sample has been ionized, the beam of ions is accelerated by an electric filed and then passes into the mass analyzers. There are many different ionization methods for different applications, there are also several types of mass analyzers. 1. Time-of-flight 2. Quadrupole 3. Quadrupole Ion trap 25

7.1 Time-of-flight (TOF) TOF mass analyser is based on the velocities of two ions , created at the same instant with the same kinetic energy , will vary depending on the mass of the ions the lighter ion will have a higher velocity. Ions are travelling toward the mass spectrometer’s detector the faster ion will strike the detector first. TOF mass analyzer is found in LC-MS system with m/z range >100–3000 . 26

Advantages:- High Mass Range. Fast Scanning. High resolution and high sensitivity. Mechanically simple. Disadvantages: - Low Accuracy . 27

7.2 Quadrupole The quadrupole mass analyzer a set of four solid rods arranged parallel to the direction of the ion beam. A DC voltage and RF is applied to the rods, generating an oscillating electrostatic filed in the region between the rods. Ions of an incorrect m/z ratio undergo unstable oscillation they ions not detected. Ions of the correct m/z ratio undergo a stable oscillation of constant amplitude and travel down the quadrupole axis with a “ corkscrew ”- type trajectory. Quadrupole mass analyzer is found in most LC-MS system with m/z range approach to 2000 . 28

Diagram of Quadrupole 29

Advantages:- Inexpensive. Easily Interfaced to Many Ionization Methods. Disadvantages:- Low Resolution. MS/MS requires multiple analyzers. Slow Scanning. 30

7.3 Quadrupole Ion trap The Quadrupole Ion trap mass analyser operates by similar principles as the quadrupole. The ion trap consists of two hyperbolic end cap electrodes and doughnut –shaped ring electrode are connected. The AC or DC and an RF potential is applied between the end caps and the ring electrode. The ion trap ions of all m/z values are in the trap simultaneously oscillating in concentric trajectories . 31

Diagram of Quadrupole Ion trap 32 Advantages:- Inexpensive. High Resolution Easily Interfaced to Many Ionization Methods. MS/MS in one analyzer. Disadvantages:- Low Mass Range. Slow Scanning.

8. Applications Molecular Weight Determination. Drug Discovery. Food Applications. Biomedical Application. Environmental Application. Biochemical Screening for Genetic Disorders. Therapeutic Drug Monitoring and Toxicology. 33

34

35

36

37

The developed LC method help to separate drug as well as all the degradation products flucloxacillin which proved its stability indicating nature. The drug degraded under acid, alkaline neutral and oxidative stress, while it was found to be stable under thermal and photolytic stress conditions. To resolve the structure of degradation product, mass fragmentation pattern of drug was established with the help of MS/TOF and MSn studies. The LC-MS hyphenated tech. helps to separate drug as well as degradation products by use of LC and the MS help to identify the structure of each degradation product as a result we can understand degradation pathway of drug molecule. The LC-MS has provide to be sensitive and specific tech. for the analysis of pharmaceutical product . 38 10. Conclusion

11. References Skoog DA ., Holler FJ., Crouch SR., Principle of Instrumental Analysis, 6 th ed., Eastern Press Banglore , 2015, page no:-806-844. Pavia, Lampman , Kriz , Vyvyan , Spectroscopy International Edition, 4 th ed., Cengage Leanng , Delhi, 2014, page no:-413-511. Chatwal GR., Anand SK., Instrumental Methods of Chemical Analysis, 5 th edition, Himalaya Publishing House, Delhi, 2014, page no:-2.56-2.67. Tiwari R. N.; Bonde C. G.; LC–MS/TOF and MSn Studies on Forced Degradation Behavior of Flucloxacillin and Development of a Validated Stability Indicating LC method , Acta Chromatographica 2014, volume-1, page no.:43-55. Hapse S.A., Bhagat B.V., Sawant P.D., Rapanwad , P.B. Hyphenated Techniques: A Review IJPPR 2017,volume-8, Issue:2, page no.:33-44. Kalpesh N Patel, Jayvadan K Patel, Introduction to Hyphenated Techniques and their Applications in Pharmacy, Review article, Pharmaceutical Methods 2010, volume-1, Issue:1, page no.:1-13 39

Blessy Mn , Ruchi D. Patel, et. al. ; Development of forced degradation and stability indicating studies of drugs—A Review “Journal of Pharmaceutical Analysis” 2013,page no.:59-165. ICH, Stability Testing of New Drug Substances and Products Q1A(R2), in: International Conference on Harmonisation, IFMPA, Geneva, 2003. ICH, Stability Testing of Photostability Testing of New Drug Substances and Products Q1B, in: International Conference on Harmonisation, IFMPA, Geneva, 1996. http://www.news-medical.net/life-sciences/Liquid-Chromatography-Mass-Spectrometry-(LC-MS)-Applications.as 40

41 Thank you