Drager PEX 3000 Fixed Gas Detector - Spec Sheet

TerryMcDonald2 195 views 2 slides Sep 08, 2014
Slide 1
Slide 1 of 2
Slide 1
1
Slide 2
2

About This Presentation

No description available for this slideshow.


Slide Content

SIX VARIANTS OF TRANSMITTERS
You can choose between two measuring
ranges (0 ... 100 or 0 ... 10 %LEL) and two dif-
ferent junction box sizes. The larger junction
box provides optional horizontal or vertical
cable entry. Where the application asks for
the sensor to be mounted remote from the
junction box then it is possible to use the
remote cable assembly combined with the
sensing head of type Polytron SE Ex.
SIMPLE INSTALLATION
The three core screened cable from the
control system terminates within the 
junction box of the Dräger PEX 3000 by
means of three Ex-approved spring 
terminals. The sensor connects to three
different Ex-approved spring terminals. 
Ex-approved spring terminals are not self-
loosening and are inherently more reliable
then standard screw terminals, therefore
self-loosening is no longer an issue!
ONE-MAN CALIBRATION
Owing to the state-of-the-art design of the
Dräger PEX 3000 it is possible to open the
Ex e junction box in the hazardous area to
perform maintenance and calibration. Using
the two internal push buttons and the inter-
nal seven segment digital display you can
perform many different activities including
one-man calibration. No additional hard-
ware is required, e.g. a hand held terminal. 
EXPLOSION PROTECTION
The Dräger PEX 3000 is approved 
according to the EU-Directive 94/9/EC to
be operated at ambient temperatures 
ranging from - 40 up to + 65 °C. This
applies to both explosive gas atmospheres
and explosive dust atmospheres (Zones 1,
2, 21, and 22). 
LOW GAS CONCENTRATIONS
For applications where it is necessary to
detect low concentrations then the trans-
mitters Dräger PEX 3000 type XTR 0010
or XTR 0011 with their special low-drift 
LC sensor are very suitable. These 
transmitters reliably detect gas leaks of
concentrations up to 10 %LEL .
NEWLY DEVELOPED: DD SENSOR
The new DD sensor is based on the 
well-known catalytic bead technology from 
Dräger and is designed and manufactured
by Dräger for long term stability and 
resistance against sensor poisons. 
Furthermore, the new DD sensor uses an
innovative non-sintered disc gas inlet 
therefore the reaction time towards the 
target gas in now only a few seconds. This
fast speed of detection allows for counter-
measures to be initiated earlier, therefore
guarding against the formation of an 
explosive atmosphere. 
Dräger PEX 3000
Fixed Gas Detector
The transmitter Dräger PEX 3000 detects flammable gases
and vapors in concentrations below their Lower Explosion
Limit. Its DD-sensor provides a very long-term stable 
measuring signal and responds to gas in only a few seconds.
D-32053-2011
D-11158-2011
Dräger PEX 3000 Typ XTR 0000
Your transmitter for standard applications:
small and robust 
Dräger PEX 3000 Typ XTR 0001
Your transmitter especially for outdoor 
applications
ST-5683-2004

DRÄG E R   P E X   3 0 0 002 |
TECH N I C A L   D A T A
Type 4 - t o - 2 0 - m A - t r a n s m i t t e r w i t h c a t a l y t i c b e a d s e n s o r
G
a
s
e
s

a
n
d

v
a
p
o
r
s
F
l
a
m
m
a
b
l
e

g
a
s
e
s

a
n
d

v
a
p
o
r
s

i
n

t
h
e

a
m
b
i
e
n
t

a
i
r

s
u
c
h

a
s

a
c
e
t
o
n
e
,

a
c
e
t
y
l
e
n
e
,

a
m
m
o
n
i
a
,

b
e
n
z
e
n
e
,

1
.
3
-
b
u
t
a
d
i
e
n
e
,

n
-
b
u
t
a
n
e
,
n
-
b
u
t
y
l

a
c
e
t
a
t
e
,

d
i
e
t
h
y
l

e
t
h
e
r
,

d
i
m
e
t
h
y
l

e
t
h
e
r
,

e
t
h
a
n
o
l
,

e
t
h
y
l

a
c
e
t
a
t
e
,

e
t
h
y
l
e
n
e

(
e
t
h
e
n
e
)
,

e
t
h
y
l
e
n
e

o
x
i
d
e
,

n
-
h
e
x
a
n
e
,

h
y
d
r
o
g
e
n
,
m
e
t
h
a
n
e
,

m
e
t
h
a
n
o
l
,

m
e
t
h
y
l

e
t
h
y
l

k
e
t
o
n
e

(
M
E
K
)
,

m
e
t
h
y
l

m
e
t
h
a
c
r
y
l
a
t
e
,

n
-
n
o
n
a
n
e
,

n
-
o
c
t
a
n
e
,

n
-
p
e
n
t
a
n
e
,

p
e
t
r
o
l

0
6
5
/
0
9
5
,

propan e , i - p r o p a n o l , p r o p y l e n e ( p r o p e n e ) , p r o p y l e n e o x i d e , t o l u e n e a n d o - x y l e n e
M
e
a
s
u
r
i
n
g

r
a
n
g
e
T
y
p

X
T
R

0
0
0
0
,

X
T
R

0
0
0
1
0

t
o

1
0
0

%
L
E
L
Typ XT R 0 0 1 0 , X T R 0 0 1 1 0 t o 1 0 % L E L
Power s u p p l y 1 2 t o 3 0 V d . c . ( n o m i n a l 2 4 V d . c . ) , m a x . 1 1 0 m A a t 2 4 V
Signal o u t p u t N o r m a l o p e r a t i o n 4 t o 2 0 m A M a i n t e n a n c e 3 . 4 m A F a u l t c o n d i t i o n < 1 . 2 m A
Cablin g 3 - c o r e , s h i e l d e d , c o r e c r o s s - s e c t i o n 0 . 7 5 t o 1 . 5 m m 2 , o u t e r d i a m e t e r 7 t o 1 2 m m
m
a
x
.

c
a
b
l
e

l
e
n
g
t
h

2
4
0
0

m

a
t

3

x

1
.
5

m
m
2
, 1600 m a t 3 x 1 . 0 m m
2
, 1200 m a t 3 x 0 . 7 5 m m
2
(at 24 V , 2 5 0 O h m s )
R
e
s
p
o
n
s
e

t
i
m
e
T
y
p
e

X
T
R

0
0
0
0
,

X
T
R

0
0
0
1
t
5
0
:

3

.
.
.

5

s
,
t
9
0
:

8

.
.
.

1
0

s
(at 25 ° C , m e t h a n e ) T y p e X T R 0 0 1 0 , X T R 0 0 1 1 t 5 0 < 9 s , t 9 0 < 2 0 s
A
m
b
i
e
n
t

c
o
n
d
i
t
i
o
n
s
T
e
m
p
e
r
a
t
u
r
e
-

4
0

t
o

+

6
5

°
C

(
d
e
p
e
n
d
i
n
g

o
n

t
e
m
p
e
r
a
t
u
r
e

c
l
a
s
s
)
P
r
e
s
s
u
r
e
7
0
0

t
o

1
3
0
0

h
P
a
Humid i t y 5 t o 9 5 % r . H .
Housin g m a t e r i a l g l a s s f i b e r r e i n f o r c e d p o l y e s t e r ( G R P )
Ingres s P r o t e c t i o n I P 6 6
D
i
m
e
n
s
i
o
n
s

(
W

x

H

x

D
)
T
y
p
e

X
T
R

0
0
x
0
c
a
.

8
0

x

1
3
0

x

5
5

m
m
Type X T R 0 0 x 1 c a . 1 3 5 x 1 1 0 x 5 5 m m
Weigh t c a . 6 0 0 g
Expec t e d s e n s o r l i f e t i m e t y p i c a l > 3 y e a r s
E
x
p
l
o
s
i
o
n

p
r
o
t
e
c
t
i
o
n
e
x
c
e
p
t

X
T
R

0
0
9
x
:
I
I

2
G

E
x

d
e

I
I
C

T
6
/
T
5
/
T
4

G
b
I
I

2
D

E
x

t

I
I
I
C

T
8
0
/
9
5
/
1
3
0

°
C

D
b

I
P
6
X
-

4
0



T
a



+

4
0

/

5
5

/

6
5

°
C
XTR 0 0 9 x : I I 2 G E x d e I I C T 6 G b I I 2 D E x t I I I C T 8 0 ° C D b I P 6 X - 4 0 ≤ T a ≤ + 6 5 ° C
Perfor m a n c e a p p r o v a l a c c . t o E N 6 0 0 7 9 - 2 9 - 1 f o r t h e a . m . g a s e s a n d v a p o r s ( 1 0 0 % L E L v a r i a n t s o n l y )
F
u
n
c
t
i
o
n
a
l

S
a
f
e
t
y
A
v
e
r
a
g
e

p
r
o
b
a
b
i
l
i
t
y

o
f

f
a
i
l
u
r
e

o
n

d
e
m
a
n
d

(
T
P

=

1

y
e
a
r
)
P
F
D

=

5
.
5
6
E
-
0
4
(100 % L E L v a r i a n t s o n l y ) S a f e f a i l u r e f r a c t i o n ( H F T = 0 , T y p e B ) S F F = 9 0 . 4 %
BEST E L L I N F O R M A T I O N
PEX 3 0 0 0 , T y p e X T R 0 0 0 0 , s m a l l h o u s i n g , 0 t o 1 0 0 % L E L 8 3 1 8 2 8 0
PEX 3 0 0 0 , T y p e X T R 0 0 0 1 , m e d i u m - s i z e d h o u s i n g , 0 . . . 1 0 0 % L E L 8 3 1 8 3 6 0
PEX 3 0 0 0 , T y p e X T R 0 0 1 0 , s m a l l h o u s i n g , 0 . . . 1 0 % L E L 8 3 1 8 2 9 0
PEX 3 0 0 0 , T y p e X T R 0 0 1 1 , m e d i u m - s i z e d h o u s i n g , 0 . . . 1 0 % L E L 8 3 1 8 3 7 0
PEX 3 0 0 0 , T y p e X T R 0 0 9 0 , s m a l l h o u s i n g , r e m o t e t r a n s m i t t e r w i t h o u t s e n s o r 8 3 1 8 3 8 0
PEX 3 0 0 0 , T y p e X T R 0 0 9 1 , m e d i u m - s i z e d h o u s i n g , r e m o t e t r a n s m i t t e r w i t h o u t s e n s o r 8 3 1 8 3 9 0
Dust f i l t e r f o r D r ä g e r S e n s o r P R M D D ( P E - d i s k s , 1 0 p i e c e s ) 6 8 1 0 5 3 7
Calibra t i o n a d a p t e r ( P E ) 6 8 0 6 9 7 8
Proces s a d a p t e r ( s t a i n l e s s s t e e l ) f o r P E X 3 0 0 0 X T R 0 0 0 0 , X T R 0 0 0 1 6 8 1 2 4 7 0
Proces s a d a p t e r ( s t a i n l e s s s t e e l ) f o r P E X 3 0 0 0 X T R 0 0 1 0 , X T R 0 0 1 1 6 8 1 2 4 6 5
90 41 354 | 06.12-2 | Marketing Communications | PP | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2012 Drägerwerk AG & Co. KGaA