INTRODUCTION
•ECG (Electrocardiograph) service in android
phones and tablets
•A compact sensor, is used to monitor the
heartbeat in analog form .
•Signals sent through Wi-Fi technology.
•We can Store the signal as history
•We can send the signals to doctor via Email.
Objective
The patient can monitor his own condition at
any time, though this he can save the life.
This system is to be available at reasonable
prices.
Embedded technology is to be use for
monitoring the patient condition easily.
METHODOLOGY
•SDLC
USECASE
PROPOSED SYSTEM
A Wi-Fi based “ECG MONITORING SYSTEM” is
used.
Mainly two parts of the system, Heart beat sensor ,
transmitter and receiver.
Hear beat sensor is used to measure heart beat rate.
The transmitter transmits the heart beat count
of patient.
Data transmitted Via Wi-Fi.
Transmitter is placed near the patient.
IMPLEMENTATION DETAILS
HARDWARE REQUIREMENTS
•On Developer Side
Processor : Dual core or above.
RAM : 4GB.
Hard disk : 40GB or above.
Monitor : 15’’ LCD or CRT Monitor or above.
Keyboard : Standard windows keyboard
•On Client Side
Device : Wi-Fi enabled Android OS
mobile 4.0 or above.
RAM : 2GB or Above
•SOFTWARE REQUIREMENTS
Development Kit: Android SDK, Java JDK, SQLite
Languages : Java,C.
IDE Emulator. : Android Studio, Android
Platform : Window XP or above.
MODULES
An Embedded technology is used here.
Hardware Modules
ADS1292 is IC
TM4C123G is used in this system.
Wi-Fi used for transmitting data.
Software Modules
BLOCK DIAGRAM
CIRCUIT DIAGRAM
VCC
VCC
Input from ECG
electrodes
9V AC
1
2
1
2
C6
1
0
0
u
F
/
1
6
V
R3
330E
C5
470uF/25V
- +
D1
DB106
1
2
3
4
D3
SSF-LXH101
C3
10uF
Y1
4 Mhz
C7
CAP
PIC16F877A
1
2
3
4
5
6
7
8
9
10
1
1
1
2
13
14
15
16
17
18
19
20
40
39
38
37
36
35
34
33
3
2
3
1
30
29
28
27
26
25
24
23 22
21
MCLR/VPP
RA0/ANO
RA1/AN1
RA2/AN2/VREF-/CVREF
RA3/AN3/VREF+
RA4/TOCKI/C1OUT
RA5/AN4/SS/C2OUT
REO/RD/AN5
RE1/W R/AN6
RE2/CS/AN7
V
D
D
V
S
S
OSC1/CLKI
OSC2/CLKO
RCO/T1OSO/T1CKI
RC1/T1OSI/CCP2
RC2/CCP1
RC3/SCK/SCL
RD0/PSP0
RD1/PSP1
RB7/PGD
RB6/PGC
RB5
RB4
RB3/PGM
RB2
RB1
RB0/INT
V
D
D
V
S
S
RD7/PSP7
RD6/PSP6
RD5/PSP5
RD4/PSP4
RC7/RX/DT
RC6/TX/CK
RC5/SDO
RC4/SDI/SDA RD3/PSP3
RD2/PSP2
R3
330E
C5
4
7
0
u
F
/
2
5
V
C5
4
7
0
u
F
/
2
5
V
C1
10uF
SW 0
RST
U1
MAX232
13
8
11
10
1
3
4
5
2
6
12
9
14
7
1
6
1
5
R1IN
R2IN
T1IN
T2IN
C+
C1-
C2+
C2-
V
+
V-
R1OUT
R2OUT
T1OUT
T2OUT
V
C
C
G
N
D
C3
10uF
P1
Z
I
G
B
E
E
M
O
D
U
L
E
5
9
4
8
3
7
2
6
1
C3
10uF
7805
GND
OUTIN
TESTING
•Unit test
•Validation tests
•Integration tests
TESTING
Test case for Registration
Test case for Login
Test case for connect ECG sensor device
to body
Test case for setting Wi-Fi Connection
Test case for plot the graph on Android screen
DATABASE TABLES
• 1. Login
Coloumn Name DataType Constraints Description
id integer Primary key User id
User Name Text Not null User Name
Password Text Not null Password
•2. Profile
Coloumn Name DataType Constraints Description
id integer Primary key Id for user
Name Text Not Null User ‘s Name
Sex Text Not Null Sex
Age integer Not Null Age
e-m ail Text Not Null Mail id
•3. History
Coloumn Name DataType Constraints Description
hid integer Primary key History id
H_volt integer Not null History volt
System Architecture
CONCLUSION
Portable and easy to use.
Prevention is better than cure.
Modern technologies have developed that
promotes comfortable and better life which is
disease free.
Applications
•Hospitals / Dispensaries
•Best to be used on rural areas.
•At homes
•Better and accurate method of measuring
heart beat.
FUTURE SCOPE
.
•Multiple parameters like Blood pressure,
retinal size, age and weight can be included as
controlling parameters in the future.