OXYGEN GAS BOOSTER SYSTEM DEZEGA HIHPG2

INTRODUCTION

Introduction КД-8 DEZEGA HIHPG2 200 – 220 bar 250 bar

SPECIFICATIONS HIHPG2 SPECIFICATIONS  Motor rating, HP 2 Current @ 220 Volts, 1-phase, Amps 10.2 Operating Speed, Cycles per minute, CPM 88 Weight , Kg 66 Noise level @ 3 ft, dB(A) 6 3 Inlet & outlet ports ¼” , JIC Male** Vent port ¼” ,  NPTF ** Cooling Fan, m3/min 5 Delta temperature ° C   8 - 14 Operational ambient temperature range , ° C   -40…+90 Inlet pressure range , М P а 2-27,5 (макс. 41) Operating pressure range , М P а 2-27,5 (макс. 41) Overall dimensions (L x W x H), mm 812x558x279 Cooling method Air-Cooled Drive type Direct Drive Stages 1-stage, Double acting

Cylinder filling calculation

BENEFITS HIHPG2 BENEFITS : Quietest Electric Driven Gas Booster System in its class: only 63 dBA Integrated system for identification of turns from plunger Air cooling for long seal life with integrated fan Simple and reliable mechanical structure (periodic replacement of two seals) Uses no belts or pulleys It is not necessary to replace oil Two-man portable

Segments and target audience of HIHPG2 Segments: mining industry Firefighting Industrial and tunnel work Diving The target audience: All existing P-30EX clients and target P-70 clients All clients of KD-8 in the markets of presence Amateur and professional diving centers.

1 – 50 or 1 station

Individual Components

Item 1: Electric Motor Item 2: Speed Reducer Item 3: Safety Relief Valve (RV-1): Prevent cylinders from being over pressured. Factory set at 28,6 MPa (4150-psi). Item 4 Gas Booster ratio 30:1: Double acting, single stage chambers, ratio 30:1. Item 6: Low Pressure Limit Switch: Normally open. Senses inlet pressure from cascade storage system and stops the system when the pressure drops below set point and automatically restarts when the pressure exceeds 2,4 MPa (350-psi). Factory set at 2 MPa (300-psi). Item 7: High Pressure Limit Switch (PS-2): Normally closed. Senses outlet pressure from the high pressure boost system and stops the system when the pressure exceeds set point and automatically restarts when the pressure drops approximately to 20 MPa (3000-psi). Factory set at 27,5 MPa (4000-psi). Item 9: Gas Inlet Filter (F-1): Remove particles down to nominal 5-10 micron that may migrate from the cascade cylinders or high pressure compressor storage tank. Note: This filter will not intercept liquid contaminates. Item 10: Gas Outlet Filters (F-2): Remove particles down to nominal 5-10 micron from the high pressure boost system discharge prior to entering the fill hose assembly (hose assembly not provided). Item 13: Випускний колектор: блок із нержавіючої сталі, опори для манометра на виході поз. 5 ( PG-2), запобіжного клапана на виході поз. 3 ( RV-1), кінцевого вимикача високого тиску поз. 7 ( PS-2), запірного клапана на виході поз. 8 (В-1) та випускний клапан поз. 8 (В-2). Розрахунковий тиск до 41,5 МПа. Crankshaft Mechanism: Cam type that provides the reciprocating action required to boost gas pressure assuring smooth running operation.

Item 5: Inlet Pressure Gauge (PG-1): Indicates the inlet pressure from cascade storage system, 0-34,5 MPa (0-5000 PSI). Item 5: Outlet Pressure Gauge (PG-2): Indicates charging air pressure, 0-34,5 MPa (0-5000 PSI). Item 8: Outlet shutoff valve (V-1): Needle type controls the gas flow through the high pressure boost system to the fill cylinder, manually operated. Item 8: Outlet Vent valve (V-2): Needle type used to release gas pressure from the high pressure gas boost system and fill cylinder. Item 11: Tubular Frame: Tubular frame with control panels and shock absorbers. Item 12: Cooling fan: Provides cooling to the high pressure boost system at a rate of 5 m3/min. Hour-meter: 6-digit analog meter used to record the operating time in hours, resettable. Input Power cable: 6-foot in length. Power plug not included. Control panel: Includes gas outlet valve item 8 (V-1), vent valve item 8 (V-2), inlet pressure gauge item 5 (PG-1), and outlet pressure gauge item 5 (PG-2).

HIHPG2-21325 OPTIONS HIHPG2-21408

Low Pressure Limit Digital Switch: Normally open. Check inlet pressure from cascade storage system and stops the system when the pressure drops below set point and automatically restarts when the pressure exceeds 2,4 MPa (350-psi). Factory set at 2 MPa (300-psi) - adjustable. High Pressure Limit Digital Switch: Normally closed. Check outlet pressure from the high pressure boost system and stops the system when the pressure exceeds set point and automatically restarts when the pressure drops approximately to 20 MPa (3000-psi). Factory set at 27,5 MPa (4000-psi) – adjustable Options

Exhaust valve (needle type): High pressure regulator outlet 0-34.5 MPa. Options

Outlet 4-port manifold: Stainless Steel block, with middle ports plugged with independent gauges, shutoff valves, vent valves, and two different outlet ports: M22x1,5 H and G1/2-A. Pressure rated to 40 MPa (6000 PSI-psi). Vents for the oxygen leaks monitoring . Options

Remote control panel: option to start the compressor from a remote room for the help of a spy. Options

Completeness Name Q-ty Compressor HIHPG2-21325: Electric drive 220-V, 1-phase, 60/50-Hz motor, with a rotation speed of 86-88 rpm. The factory setting of the high pressure limit is 27.5 MPa; Booster model 2GB30304-O; Low pressure limit switch. Factory setting at 2 MPa; High pressure limit switch. The factory setting is 27.5 MPa; Manometers at the entrance and exit; Filters at the entrance and exit; Shut-off valve at the outlet (needle type);Exhaust valve (needle type); Cooling fan; Engine hours counter; 2 m hose, for connection to a transport cylinder with a G3/4 thread; Hose 1 m, for connection to a small cylinder with a thread according to the customer's cylinders; Adapter for cylinder P-30 or P-70; Black tubular frame with mounted control panel; 1 User manual 1 Wooden box 1 OPTIONS (to be set when ordering) Low Pressure Limit Digital Switch High Pressure Limit Digital Switch Outlet 4-port manifold Exhaust valve (needle type) Vents Remote control

Installation and Operation

Install the booster in a ventilated room with a free space of 20-30 cm around it. Connect the booster to the 220V network with a power cord. Connect the high-pressure inlet and outlet hoses to the unit. Check the reliability of connections, readings of pressure gauges, closing of valves.

Power up the unit. Slowly open the valve of the transport cylinder. At the same time, the pressure gauges of the input and output groups must show the same gas pressure in the system. Slowly open the valve of the small cylinder, and then the exhaust valve. If the pressure in the low-volume cylinder is lower than in the system, the pumping process will take place automatically. If the pressure in the system is lower than the set one, the start switch is turned on the system panel, which activates the operation of the compressor

When the gas cools after pumping, the pressure in the cylinder drops, so if necessary, you can repeat the procedure after a few minutes and bring the pressure to the specified level. After successful refueling, close all compressor valves and the valve in the refueled cylinder. Residual oxygen under pressure in the system is released with the help of the exhaust valve by slowly opening it. After disconnecting the cylinder from the system and preparing for refueling the next one.

Conclusions

Conclusions The lightest and quietest air-cooled compressor in its class. The fair market price is on average 20% lower than that of direct competitors. The direct drive greatly simplifies maintenance, not requiring periodic replacement of the drive belt, lubricant, etc. In general, only two sets of seals in the piston system need to be replaced. All compressor connections go perpendicularly to the right of the control panel of the operator standing on the side of the panel. A wide range of options to increase the efficiency and ease of use of the compressor: - high pressure flexible hose; - automatic digital switches of low and high pressure; - Needle-type outlet valve; - Output 4-port collector. Warranty and post-warranty service for users, on the basis of the DEZEGA service center and partners around the world, is carried out by experienced workers with many years of experience. Quality and time-tested compressor A well-known reliable manufacturer with more than 60 years of good reputation and openness in communications. A brand that is recommended to colleagues and partners, and which is recognized and successful all over the world!