About This Presentation

introduction
types
instrumentation
application
advantages
disadvantages


Slide Content

Presentation On Gas chromatography By Machhi Dhruvi Anilkumar From 1 st sem M. Pharm ( P’ceutical Quality Assurance) Course name & Code: Modern P’ceutical Analytical Techniques M AT101T Smt. B. N. B. Swaminarayan Pharmacy College, Salvav -Vapi

Contents:- Introduction Types Principle Instrumentation Application Advantages Disadvantages 12/19/2021 Dhruvi Machhi 2

Introduction :- It is the process of separating components from the given crude drug by using gaseous mobile phase. It involves a sample which is being vaporized & injected onto the head of the chromatographic column. The sample is transported through the column by the flow of inert gaseous mobile phase. The column itself contains a liquid stationary phase which is absorbed onto the surface of an inert solid. 12/19/2021 Dhruvi Machhi 3

Types :- Gas chromatography Gas-liquid chromatography Gas-solid chromatography Mobile phase is gas Stationary phase is solid Mobile phase is gas Stationary phase is liquid retained on inert solid 12/19/2021 Dhruvi Machhi 4

Principle :- In gas-solid chromatography, solid adsorbent is used as a stationary phase & separation takes place through adsorption process while in gas- liquid chromatography, the stationary phase consists of thin layer of non-volatile liquid bound to solid support & separation takes place through the process of partition . Gas-liquid chromatography is most commoly used technique. The sample which is to be separated is first converted into vapours & thus mixed with gaseous mobile phase. Components of a sample that are more soluble in stationary phase travels slower & the components that are less soluble in stationary phase travels faster. The components are thus separated according to their partition co-efficient. 12/19/2021 Dhruvi Machhi 5

Instrumentation :- Carrier gas Flow regulators Sample introduction system Column Temperature control device Detectors Recorders 12/19/2021 Dhruvi Machhi 6

Schematic Diagram :- 12/19/2021 Dhruvi Machhi 7

1. Carrier gas :- A carrier gas plays a vital role in GC. It should be inert ,dry & free of oxygen. Helium , Nitrogen, argon & hydrogen gases are used as carrier gas depending upon the desired performance & detector being used . Helium & nitrogen are most common used carrier gas. Carrier gas is supplied at high pressure & is passed to instrument at a rapid & reproducible rate. 12/19/2021 Dhruvi Machhi 8

2. Flow regulators :- As carrier gases are stored under high pressure, flow regulators are used to deliver the gas with uniform pressure as well as flow rate. Inlet pressure: ranges from -10 to 50 psi Flow rate : 25-150 ml/min for packed column & 2-25 ml/min for open tubular column 12/19/2021 Dhruvi Machhi 9

3. Sample introduction system :- A sample port is necessary for the sample at the head of the column. A calibrated microsyringe is used to transfer a volume of sample through a rubber septum and thus into the vaporization chamber. Most of the separations require only a small fraction of the initial sample volume and a sample splitter is used to direct excess sample to waste. 12/19/2021 Dhruvi Machhi 10

Commercial gas chromatography involves the use of both split and splitless injections when alternating between packed columns and capillary columns. The vaporization chamber is typically heated 50 °C above the lowest boiling point of the sample and subsequently mixed with the carrier gas to transport the sample into the column. 12/19/2021 Dhruvi Machhi 11

12/19/2021 Dhruvi Machhi 12

4. Column :- Column is one of the important part of GC which decides separation. Made up of Glass or Stainless Steel. Columns Support coated open tubular Columns (SCOT) Well coated open tubular Columns (WCOT) 12/19/2021 Dhruvi Machhi 13

Well coated open tubular Columns (WCOT) Columns have a thin layer of the stationary phase coated along the column walls. Support coated open tubular Columns (SCOT) The column walls are first coated with a thin layer of adsorbant solid The adsorbant solid is then treated with the liquid stationary phase. One of the most popular types of capillary columns is called the coated Fused Silica open tubular column. 12/19/2021 Dhruvi Machhi 14

5. Temperature control devices :- (1) Preheaters :- It is used in GC to convert the sample into vapour form & mix them with the mobile phase or carrier gas. It is present along with injecting device. 12/19/2021 Dhruvi Machhi 15

(2) Column oven / Thermostatically controlled oven :- The oven are there to control the temperature of the column to conduct precise work. The oven can be operated in two manners: isothermal programming & temperature programming. In isothermal programming , the temperature of the column is held constant throughout the whole separation & in temperature programming method, the column temperature is either increased continuously or in steps as the separation progresses. 12/19/2021 Dhruvi Machhi 16

Column oven 12/19/2021 Dhruvi Machhi 17

6. Detectors :- Detectors are most important part of GC & considered as Heart of the apparatus . Eluted solute along with the carrier gas exit from the column & enter the detector Detectors then produce electrical signals proportional to the concentration of solute component Signals are amplified & recorded as peaks at intervals on chromatograph 12/19/2021 Dhruvi Machhi 18

Most common types of detectors used in GC are; Mass Spectrometer Flame ionization detector (FID) Electron capture detector (ECD) Thermal conductivity detector (TCD) Atomic emission detector (AED) Photo ioniztion detector (PID) Chemilumnescence detector 12/19/2021 Dhruvi Machhi 19

7. Recorders :- It is used to record the response obtained from detectors after amplification. They record baseline & all peaks obtained with respect to time. These use special electronic circuits & amplify the signals so as to display in an understandable graphical format that represents several peaks of the constituents of the sample under analysis. 12/19/2021 Dhruvi Machhi 20

12/19/2021 Dhruvi Machhi 21

How GC works? Firstly vaporized sample is injected into the chromatographic column Then sample moves through the column with the flow of inert gas results in the separation of the components of sample They are recorded as a sequence of peaks as they leave the column Different components of the sample separated & eluted at different & particular time i.e. retention time 12/19/2021 Dhruvi Machhi 22

Applications :- GC has wide range of applications in various fields .It has a medicinal & pharmaceutical applications. It is used in food, beverage, flavor & fragrance analysis. It is also helpful in environmental analysis and monitoring. In forensics, it is used in detection of body fluids, for the testing of fiber , blood alcohol, detection of poisons , pesticides & also to detect explosives residues. It is also useful in Security and chemical warfare agent detection. 12/19/2021 Dhruvi Machhi 23

Identification of hazardous compounds in waste damps. Quantification of drugs & their metabolites in blood & urine for both pharmacological & forensic applications. Quantification of pollutants in drinking & waste water. Analysis of industrial products for quality control. Skin sample analysis. RNA isolation. In geochemical search. 12/19/2021 Dhruvi Machhi 24

Advantages :- The technique has strong separation power & even complex mixture can be resolved into constituents The sensitivity of method is quite high. It is a micro method & only few milligram of sample is sufficient for analysis . It gives good precision & accuracy. The analysis is completed in short time. 12/19/2021 Dhruvi Machhi 25

Disadvantages :- Limited to volatile compounds Only thermally stable compounds can be separated Sampe should be soluble but do not react with the column 12/19/2021 Dhruvi Machhi 26

References :- Principles of Instrumental analysis- Doglas A. Skoog, F. James Holler, 6 th edition, page no. 788-815 Kaur, Gurleen, and Sahil Sharma. "Gas Chromatography–A Brief Review”, International journal of information and computing science, volume 5, issue 7, july 2018, 125-131 Gas chromatography analytical chemistry by open learning – Ian A. Fowlis ,2 nd edition 12/19/2021 Dhruvi Machhi 27

Thank you 12/19/2021 Dhruvi Machhi 28